16ch Flex Speeder Medium 1.5t

16ch Flex Speeder Medium is an MRI receive coil for use with Canon 1.5-tesla magnetic resonance systems. It is intended to help produce diagnostic images of general human anatomy for…

Registry build 21.09.26

16ch Flex Speeder Medium is an MRI receive coil for use with Canon 1.5-tesla magnetic resonance systems. It is intended to help produce diagnostic images of general human anatomy for interpretation by a trained physician.

The coil has a sixteen-channel phased-array design. It receives radiofrequency signals from the imaged anatomy as part of the scanner’s imaging process. Its electrical design includes active PIN-diode switching and passive blocking circuitry.

Enclosure

Polycarbonate provides impact protection, with a polyurethane-coated nylon fabric cover. The coil is designed for use as the Medium configuration in the compatible Canon system.

9manufacturers in China registered for this device type
1catalogue number
33510(k) clearances naming this product code
9recalls on this code

Who Else Makes It

Concentrated in Shanghai (3), Guangdong (2), Tianjin (2).

Chinese manufacturers registered for FDA product code MOS
Manufacturer City Province Registered as Device types
GE Healthcare (China) Co., Ltd. Beijing Beijing Specification developer 22
Shanghai United Imaging Healthcare Co., Ltd. Shanghai Shanghai Manufacturer 12
Siemens Shenzhen Magnetic Resonance Ltd. Shenzhen Guangdong Contract manufacturer 8
Philips Healthcare (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 5
GE Healthcare (Tianjin) Company Limited Tianjin Tianjin Specification developer 5
GE Healthcare (China) Co., Ltd. – Tianjin Tianjin Tianjin Specification developer 3
Shenzhen RF Tech Co., Ltd. Shenzhen Guangdong Complaint-file establishment 2
Shanghai Chenguang Medical Technologies Co., Ltd. Shanghai Shanghai Contract manufacturer 2
Shanghai Chenshi Medical Instruments Co., Ltd. Shanghai Shanghai Exporter 2

Record

Regulatory record for 16ch Flex Speeder Medium 1.5T
Listed by Quality Electrodynamics, United States
FDA product code MOS
Device type Coil, Magnetic Resonance, Specialty
Device class Class 2
Regulation 21 CFR 892.1000
Establishment Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer, Exporter
510(k) K244054
Record published 2025-05-20

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for 16ch Flex Speeder Medium 1.5T
Catalogue number Size Status
Q7000246 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Dunlee Sentinelle Philips Medical Systems Nederland B.V. 192
Invivo Philips DS North America LLC 185
Philips Philips DS North America LLC 88
Coil, Magnetic Resonance, Specialty Usa Instruments, Inc. 50
Philips Shanghai Chenguang Medical Technologies Co., Ltd. 50
GE Philips DS North America LLC 41
MR Coils Philips Medical Systems Nederland B.V. 37
MRI Coils Philips DS North America LLC 24
DuoFLEX® Coil Suite M R Instruments, Inc. 20
RFT Shenzhen RF Tech Co., Ltd. 18
AtamA™ System Monteris Medical Corp 17
Philips Sentinelle Philips Medical Systems Nederland B.V. 16

Showing 12 of 713. All products under Coil, Magnetic Resonance, Specialty

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K244054 2025-02-28
K233652 2024-02-16
K233656 2024-02-15
K223429 2023-01-13
K200477 2020-04-08
K193140 2020-01-03
K183111 2018-12-07
K181697 2018-07-11
K173469 2018-01-09
K173446 2017-11-17
K162946 2017-01-06
K162623 2016-12-09
K162966 2016-11-30
K163066 2016-11-29
K162029 2016-10-18
K161193 2016-06-02
K152695 2015-11-18
K151753 2015-08-27
K151829 2015-07-29
K150331 2015-04-09
K142802 2014-11-24
K142002 2014-08-22
K140998 2014-07-11
K122638 2012-09-25
K120627 2012-03-29
K120290 2012-02-28
K112313 2011-09-09
K103185 2011-02-25
K093667 2010-01-28
K091114 2009-05-01
K083160 2008-11-07
K082636 2008-09-25
K072935 2007-10-31

Recalls

8 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2019-08-20 Class II Nonconforming Material/Component Unintended ferrous material may be present within the pushbutton assembly of Siemens Knee and Siemens Extremity Coils. 3 units 2020-05-26
2019-08-20 Class II Nonconforming Material/Component Unintended ferrous material may be present within the pushbutton assembly of Siemens Knee and Siemens Extremity Coils. 21 units 2020-05-26
2019-08-20 Class II Nonconforming Material/Component Unintended ferrous material may be present within the pushbutton assembly of Siemens Knee and Siemens Extremity Coils. 36 units 2020-05-26
2019-08-20 Class II Nonconforming Material/Component Unintended ferrous material may be present within the pushbutton assembly of Siemens Knee and Siemens Extremity Coils. 3 units 2020-05-26
2019-08-20 Class II Nonconforming Material/Component Unintended ferrous material may be present within the pushbutton assembly of Siemens Knee and Siemens Extremity Coils. 5 units 2020-05-26
2019-08-20 Class II Nonconforming Material/Component Unintended ferrous material may be present within the pushbutton assembly of Siemens Knee and Siemens Extremity Coils. 5 units 2020-05-26
2019-08-20 Class II Nonconforming Material/Component Unintended ferrous material may be present within the pushbutton assembly of Siemens Knee and Siemens Extremity Coils. 2 units 2020-05-26
2012-07-27 Class II Error in labeling On July 27, 2012, it was reported to the firm that the Siemens 3T 15ch Knee Coil was not functional because the coil identification code for the device was incorrect. 17 units 2013-02-19
2008-12-29 Not classified Device Design The firm received a complaint indicating that the mirror is high risk and could drop on a patient. 5 units 2012-04-25

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer