Wrist Speeder Coil
2 catalogue numbers from Q7000005, listed by Quality Electrodynamics, United States, under Coil, Magnetic Resonance, Specialty. 9 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Shanghai (3), Guangdong (2), Tianjin (2).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| GE Healthcare (China) Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| Shanghai United Imaging Healthcare Co., Ltd. | Shanghai | Shanghai | Manufacturer | 12 |
| Siemens Shenzhen Magnetic Resonance Ltd. | Shenzhen | Guangdong | Contract manufacturer | 8 |
| Philips Healthcare (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 5 |
| GE Healthcare (Tianjin) Company Limited | Tianjin | Tianjin | Specification developer | 5 |
| GE Healthcare (China) Co., Ltd. – Tianjin | Tianjin | Tianjin | Specification developer | 3 |
| Shenzhen RF Tech Co., Ltd. | Shenzhen | Guangdong | Complaint-file establishment | 2 |
| Shanghai Chenguang Medical Technologies Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 2 |
| Shanghai Chenshi Medical Instruments Co., Ltd. | Shanghai | Shanghai | Exporter | 2 |
Record
| Listed by | Quality Electrodynamics, United States |
|---|---|
| FDA product code | MOS |
| Device type | Coil, Magnetic Resonance, Specialty |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1000 |
| Establishment | Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K072935 |
| Record published | 2016-09-16 |
| Record revised | 2020-03-05 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| Q7000005 | In distribution | |
| Q7000081 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Dunlee Sentinelle | Philips Medical Systems Nederland B.V. | 192 |
| Invivo | Philips DS North America LLC | 185 |
| Philips | Philips DS North America LLC | 88 |
| Coil, Magnetic Resonance, Specialty | Usa Instruments, Inc. | 50 |
| Philips | Shanghai Chenguang Medical Technologies Co., Ltd. | 50 |
| GE | Philips DS North America LLC | 41 |
| MR Coils | Philips Medical Systems Nederland B.V. | 37 |
| MRI Coils | Philips DS North America LLC | 24 |
| DuoFLEX® Coil Suite | M R Instruments, Inc. | 20 |
| RFT | Shenzhen RF Tech Co., Ltd. | 18 |
| AtamA™ System | Monteris Medical Corp | 17 |
| Philips Sentinelle | Philips Medical Systems Nederland B.V. | 16 |
Showing 12 of 713. All products under Coil, Magnetic Resonance, Specialty
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K244054 | 2025-02-28 |
| K233652 | 2024-02-16 |
| K233656 | 2024-02-15 |
| K223429 | 2023-01-13 |
| K200477 | 2020-04-08 |
| K193140 | 2020-01-03 |
| K183111 | 2018-12-07 |
| K181697 | 2018-07-11 |
| K173469 | 2018-01-09 |
| K173446 | 2017-11-17 |
| K162946 | 2017-01-06 |
| K162623 | 2016-12-09 |
| K162966 | 2016-11-30 |
| K163066 | 2016-11-29 |
| K162029 | 2016-10-18 |
| K161193 | 2016-06-02 |
| K152695 | 2015-11-18 |
| K151753 | 2015-08-27 |
| K151829 | 2015-07-29 |
| K150331 | 2015-04-09 |
| K142802 | 2014-11-24 |
| K142002 | 2014-08-22 |
| K140998 | 2014-07-11 |
| K122638 | 2012-09-25 |
| K120627 | 2012-03-29 |
| K120290 | 2012-02-28 |
| K112313 | 2011-09-09 |
| K103185 | 2011-02-25 |
| K093667 | 2010-01-28 |
| K091114 | 2009-05-01 |
| K083160 | 2008-11-07 |
| K082636 | 2008-09-25 |
| K072935 | 2007-10-31 |
Recalls
8 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2019-08-20 | Class II | Nonconforming Material/Component | Unintended ferrous material may be present within the pushbutton assembly of Siemens Knee and Siemens Extremity Coils. | 3 units | 2020-05-26 |
| 2019-08-20 | Class II | Nonconforming Material/Component | Unintended ferrous material may be present within the pushbutton assembly of Siemens Knee and Siemens Extremity Coils. | 21 units | 2020-05-26 |
| 2019-08-20 | Class II | Nonconforming Material/Component | Unintended ferrous material may be present within the pushbutton assembly of Siemens Knee and Siemens Extremity Coils. | 36 units | 2020-05-26 |
| 2019-08-20 | Class II | Nonconforming Material/Component | Unintended ferrous material may be present within the pushbutton assembly of Siemens Knee and Siemens Extremity Coils. | 3 units | 2020-05-26 |
| 2019-08-20 | Class II | Nonconforming Material/Component | Unintended ferrous material may be present within the pushbutton assembly of Siemens Knee and Siemens Extremity Coils. | 5 units | 2020-05-26 |
| 2019-08-20 | Class II | Nonconforming Material/Component | Unintended ferrous material may be present within the pushbutton assembly of Siemens Knee and Siemens Extremity Coils. | 5 units | 2020-05-26 |
| 2019-08-20 | Class II | Nonconforming Material/Component | Unintended ferrous material may be present within the pushbutton assembly of Siemens Knee and Siemens Extremity Coils. | 2 units | 2020-05-26 |
| 2012-07-27 | Class II | Error in labeling | On July 27, 2012, it was reported to the firm that the Siemens 3T 15ch Knee Coil was not functional because the coil identification code for the device was incorrect. | 17 units | 2013-02-19 |
| 2008-12-29 | Not classified | Device Design | The firm received a complaint indicating that the mirror is high risk and could drop on a patient. | 5 units | 2012-04-25 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.