DR 400
DR 400 5520/200 Automatic
Who Else Makes It
Concentrated in Shanghai (5), Jiangsu (4), Beijing (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Shantou Institute OF Ultrasonic Instruments Co., Ltd. | Shantou | Guangdong | Contract manufacturer | 8 |
| iRay Imaging Technology (Haining) Limited | Haining | Zhejiang | Contract manufacturer | 6 |
| iRay Imaging Technology Taicang Limited | Taicang | Jiangsu | Contract manufacturer | 3 |
| GE Hangwei Medical Systems Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| GE Healthcare (China) Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| Shanghai United Imaging Healthcare Co., Ltd. | Shanghai | Shanghai | Manufacturer | 12 |
| Siemens Shanghai, Medical Equipment Ltd. | Shanghai | Shanghai | Contract manufacturer | 10 |
| Carestream Health, Inc., Global R&D Center | Shanghai | Shanghai | Specification developer | 8 |
| Philips Healthcare (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 5 |
| iRay Group | Shanghai | Shanghai | Specification developer | 4 |
| Fujifilm Imaging System (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 3 |
| Careray Digital Medical Technology Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 2 |
Showing 12 of 13. All 13 manufacturers in China registered for Solid State X-Ray Imager (Flat Panel/Digital Imager)
Record
| Listed by | Agfa Healthcare Inc., Canada |
|---|---|
| FDA product code | MQB |
| Device type | Solid State X-Ray Imager (Flat Panel/Digital Imager) |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1680 |
| Establishment | Specification developer, Manufacturer |
| 510(k) | K141192 |
| Record published | 2016-09-01 |
| Record revised | 2019-06-14 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 5520/100 | In distribution | |
| 5520/200 | In distribution | |
| 5520/150 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Sedecal | Sedecal., Sa. | 70 |
| Schick33 | Sirona Dental, Inc. | 44 |
| Drgem | Drgem Corporation | 41 |
| Schick | Dentsply LLC | 35 |
| Wireless Digital Flat Panel Detector | iRay Group | 27 |
| Fuji IP Cassette CC | Fujifilm Corporation | 20 |
| Canon Inc. | Canon Inc. | 20 |
| Fona Stellaris | Sirona Dental, Inc. | 20 |
| Exprimer | Drtech Corporation | 18 |
| Solid State X-Ray Imager (Flat Panel/Digital Imager) | Samsung Electronics Co., Ltd. | 17 |
| X-ray Flat Panel Detector | Careray Digital Medical Technology Co., Ltd. | 16 |
| Regius Cassette | Konica Minolta, Inc. | 16 |
Showing 12 of 509. All products under Solid State X-Ray Imager (Flat Panel/Digital Imager)
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K081963 | 2008-07-25 |
| K071162 | 2007-05-08 |
| K063421 | 2006-11-22 |
| K062742 | 2006-10-13 |
| K062223 | 2006-09-01 |
| K053634 | 2006-01-17 |
| K050810 | 2005-04-21 |
| K041701 | 2004-07-22 |
| K012750 | 2001-11-14 |
Recalls
2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2016-12-21 | Class II | Device Design | A customer reported that when using an NX workstation with software version NX 3.0.8950 software and selecting the affected patient/exam from closed exams, initially the wrong image was linked to the exam and appeared. After a short time t | 221 units | 2019-07-10 |
| 2013-02-07 | Class II | Nonconforming Material/Component | The cassettes were shipped with the wrong IP (image plate) size bar code. | 17 | 2013-06-06 |
| 2012-01-16 | Not classified | Device Design | The firm received a complaint that when using the DX-D Mobile DR X-Ray unit they noticed the detector cable was hot. | 42 units | 2012-05-10 |
| 2011-12-06 | Not classified | Software design | Occasionally images can be lost or sent to an incorrect folder or the digitizer may stop either during startup or during a cassette scan cycle. | 125 | 2012-04-11 |
| 2011-03-04 | Not classified | Other | When a radiographer is working on two open studies on an NX workstation and, in specific situations, a problem of image/annotation mix-up can occur on the NX system. | 775 units | 2012-03-27 |
| 2010-10-08 | Not classified | Other | Packaging was switched between a DX-G Digitizer and a DX-M Digitizer, resulting in the wrong product, which is not sold in the US, being shipped to the consignee. | One unit | 2010-12-30 |
| 2010-06-30 | Not classified | Other | Monitor fell from the mounting bracket used to support the monitor. | 805 units | 2011-04-28 |
| 2006-06-28 | Not classified | Other | Three separate issues involving the Agfa DX-S CR System, were detected that could lead to an image loss. | 11 units | 2007-05-10 |
| 2005-11-03 | Not classified | Other | Corrupted image after system start; Corrupted image after workflow interruption; An erasure unit problem can cause system to stop. | 3 units | 2006-06-20 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.