DuraDiagnost
The DuraDiagnost is intended for use in generating radiographic images of human anatomy by qualified/trained doctor or technician. Applications can be performed with the patient sitting,…
The DuraDiagnost is intended for use in generating radiographic images of human anatomy by qualified/trained doctor or technician. Applications can be performed with the patient sitting, standing, or lying in the prone or supine position. This device is not intended for mammographic applications.
Who Else Makes It
Concentrated in Shanghai (5), Jiangsu (4), Beijing (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Shantou Institute OF Ultrasonic Instruments Co., Ltd. | Shantou | Guangdong | Contract manufacturer | 8 |
| iRay Imaging Technology (Haining) Limited | Haining | Zhejiang | Contract manufacturer | 6 |
| iRay Imaging Technology Taicang Limited | Taicang | Jiangsu | Contract manufacturer | 3 |
| GE Hangwei Medical Systems Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| GE Healthcare (China) Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| Shanghai United Imaging Healthcare Co., Ltd. | Shanghai | Shanghai | Manufacturer | 12 |
| Siemens Shanghai, Medical Equipment Ltd. | Shanghai | Shanghai | Contract manufacturer | 10 |
| Carestream Health, Inc., Global R&D Center | Shanghai | Shanghai | Specification developer | 8 |
| Philips Healthcare (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 5 |
| iRay Group | Shanghai | Shanghai | Specification developer | 4 |
| Fujifilm Imaging System (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 3 |
| Careray Digital Medical Technology Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 2 |
Showing 12 of 13. All 13 manufacturers in China registered for Solid State X-Ray Imager (Flat Panel/Digital Imager)
Record
| Listed by | Philips Healthcare (Suzhou) Co., Ltd., China |
|---|---|
| FDA product code | MQB |
| Device type | Solid State X-Ray Imager (Flat Panel/Digital Imager) |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1680 |
| Establishment | Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer |
| Record published | 2016-09-23 |
| Record revised | 2025-07-04 (version 6) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | serial number |
| Storage | Storage environment humidity 10 to 95 % RH; Handling environment atmospheric pressure 70 to 106 KiloPascal; Handling environment humidity 30 to 75 % RH; Storage environment temperature -10 to 55 °C; Storage environment atmospheric pressure 70 to 106 KiloPascal; Handling environment temperature 18 to 30 °C |
| Distribution end date | 2020-10-31 |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| DuraDiagnost | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Sedecal | Sedecal., Sa. | 70 |
| Schick33 | Sirona Dental, Inc. | 44 |
| Drgem | Drgem Corporation | 41 |
| Schick | Dentsply LLC | 35 |
| Wireless Digital Flat Panel Detector | iRay Group | 27 |
| Fuji IP Cassette CC | Fujifilm Corporation | 20 |
| Canon Inc. | Canon Inc. | 20 |
| Fona Stellaris | Sirona Dental, Inc. | 20 |
| Exprimer | Drtech Corporation | 18 |
| Solid State X-Ray Imager (Flat Panel/Digital Imager) | Samsung Electronics Co., Ltd. | 17 |
| X-ray Flat Panel Detector | Careray Digital Medical Technology Co., Ltd. | 16 |
| Regius Cassette | Konica Minolta, Inc. | 16 |
Showing 12 of 509. All products under Solid State X-Ray Imager (Flat Panel/Digital Imager)
Recalls Naming This Product
1 recall names this product by its own identifier, the UDI on its label.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Philips North America LLC | UDI-DI | 2025-03-10 | Class II | Under Investigation by firm | Potential for collimator to fall as a result of incorrect installation. | 83 units |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.