NX

NX 2.0 Software

Registry build 21.09.26
13manufacturers in China registered for this device type
1catalogue number
9510(k) clearances naming this product code
9recalls on this code

Who Else Makes It

Concentrated in Shanghai (5), Jiangsu (4), Beijing (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code MQB
Manufacturer City Province Registered as Device types
Shantou Institute OF Ultrasonic Instruments Co., Ltd. Shantou Guangdong Contract manufacturer 8
iRay Imaging Technology (Haining) Limited Haining Zhejiang Contract manufacturer 6
iRay Imaging Technology Taicang Limited Taicang Jiangsu Contract manufacturer 3
GE Hangwei Medical Systems Co., Ltd. Beijing Beijing Specification developer 22
GE Healthcare (China) Co., Ltd. Beijing Beijing Specification developer 22
Shanghai United Imaging Healthcare Co., Ltd. Shanghai Shanghai Manufacturer 12
Siemens Shanghai, Medical Equipment Ltd. Shanghai Shanghai Contract manufacturer 10
Carestream Health, Inc., Global R&D Center Shanghai Shanghai Specification developer 8
Philips Healthcare (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 5
iRay Group Shanghai Shanghai Specification developer 4
Fujifilm Imaging System (Suzhou) Co., Ltd. Suzhou Jiangsu Manufacturer 3
Careray Digital Medical Technology Co., Ltd. Suzhou Jiangsu Manufacturer 2

Showing 12 of 13. All 13 manufacturers in China registered for Solid State X-Ray Imager (Flat Panel/Digital Imager)

Record

Regulatory record for NX
Listed by Agfa Healthcare Inc., Canada
FDA product code MQB
Device type Solid State X-Ray Imager (Flat Panel/Digital Imager)
Device class Class 2
Regulation 21 CFR 892.1680
Establishment Specification developer, Manufacturer
510(k) K141602
Record published 2016-09-01
Record revised 2023-12-04 (version 7)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only

Catalogue Numbers

Catalogue numbers for NX
Catalogue number Size Status
2.0. In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Sedecal Sedecal., Sa. 70
Schick33 Sirona Dental, Inc. 44
Drgem Drgem Corporation 41
Schick Dentsply LLC 35
Wireless Digital Flat Panel Detector iRay Group 27
Fuji IP Cassette CC Fujifilm Corporation 20
Canon Inc. Canon Inc. 20
Fona Stellaris Sirona Dental, Inc. 20
Exprimer Drtech Corporation 18
Solid State X-Ray Imager (Flat Panel/Digital Imager) Samsung Electronics Co., Ltd. 17
X-ray Flat Panel Detector Careray Digital Medical Technology Co., Ltd. 16
Regius Cassette Konica Minolta, Inc. 16

Showing 12 of 509. All products under Solid State X-Ray Imager (Flat Panel/Digital Imager)

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K081963 2008-07-25
K071162 2007-05-08
K063421 2006-11-22
K062742 2006-10-13
K062223 2006-09-01
K053634 2006-01-17
K050810 2005-04-21
K041701 2004-07-22
K012750 2001-11-14

Recalls

2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2016-12-21 Class II Device Design A customer reported that when using an NX workstation with software version NX 3.0.8950 software and selecting the affected patient/exam from closed exams, initially the wrong image was linked to the exam and appeared. After a short time t 221 units 2019-07-10
2013-02-07 Class II Nonconforming Material/Component The cassettes were shipped with the wrong IP (image plate) size bar code. 17 2013-06-06
2012-01-16 Not classified Device Design The firm received a complaint that when using the DX-D Mobile DR X-Ray unit they noticed the detector cable was hot. 42 units 2012-05-10
2011-12-06 Not classified Software design Occasionally images can be lost or sent to an incorrect folder or the digitizer may stop either during startup or during a cassette scan cycle. 125 2012-04-11
2011-03-04 Not classified Other When a radiographer is working on two open studies on an NX workstation and, in specific situations, a problem of image/annotation mix-up can occur on the NX system. 775 units 2012-03-27
2010-10-08 Not classified Other Packaging was switched between a DX-G Digitizer and a DX-M Digitizer, resulting in the wrong product, which is not sold in the US, being shipped to the consignee. One unit 2010-12-30
2010-06-30 Not classified Other Monitor fell from the mounting bracket used to support the monitor. 805 units 2011-04-28
2006-06-28 Not classified Other Three separate issues involving the Agfa DX-S CR System, were detected that could lead to an image loss. 11 units 2007-05-10
2005-11-03 Not classified Other Corrupted image after system start; Corrupted image after workflow interruption; An erasure unit problem can cause system to stop. 3 units 2006-06-20

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer