Selenia Ffdm
29 catalogue numbers from ASY-06753, listed by Hologic, Inc., United States, under Full Field Digital, System, X-Ray, Mammographic. 1 manufacturer in China is registered for this product code.
Who Else Makes It
Registered in Jiangsu.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Fujifilm Imaging System (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 3 |
Record
| Listed by | Hologic, Inc., United States |
|---|---|
| FDA product code | MUE |
| Device type | Full Field Digital, System, X-Ray, Mammographic |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1715 |
| Establishment | Remanufacturer, Specification developer, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | P010025 |
| Record published | 2017-03-30 |
| Record revised | 2024-08-16 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | lot or batch number, manufacturing date, serial number |
| Distribution end date | 2018-12-31 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| ASY-06753 | Withdrawn | |
| ASY-06754 | Withdrawn | |
| FAB-00752 | Withdrawn | |
| 4-000-0144 | Withdrawn | |
| 3-000-4617 | Withdrawn | |
| 4-000-0293 | Withdrawn | |
| FAB-00609 | Withdrawn | |
| 5-000-0073 | Withdrawn | |
| ASY-05468 | Withdrawn | |
| ASY-00676 | Withdrawn | |
| ASY-06755 | Withdrawn | |
| FAB-00608 | Withdrawn | |
| ASY-06758 | Withdrawn | |
| ASY-06717 | Withdrawn | |
| ASY-01366 | Withdrawn | |
| ASY-00834 | Withdrawn | |
| 5-000-0072 | Withdrawn | |
| ASY-01656 | Withdrawn | |
| ASY-07973 | Withdrawn | |
| ASY-01427 | Withdrawn | |
| 3-535-0012 | Withdrawn | |
| 4-000-0308 | Withdrawn | |
| ASY-06716 | Withdrawn | |
| 3-000-1528 | Withdrawn | |
| ASY-06714 | Withdrawn | |
| 3-535-0087 | Withdrawn | |
| FAB-00754 | Withdrawn | |
| FAB-00610 | Withdrawn | |
| ASY-06715 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Selenia® Dimensions® | Hologic, Inc. | 47 |
| Full Field Digital, System, X-Ray, Mammographic | GE Medical Systems, LLC | 10 |
| Senographe Pristina | GE Medical Systems, LLC | 10 |
| Directview CR Mammography Cassette with EHR-M Screen | Carestream Health, Inc. | 10 |
| Giotto Class | IMS Giotto SPA | 6 |
| Directview CR Mammography Cassette with EHR-M3 Screen | Carestream Health, Inc. | 5 |
| Giotto Image 3DL | I.M.S. Internazionale Medico Scientifica SRL | 5 |
| CR-IR 392 | Fujifilm Corporation | 3 |
| Giotto Image | IMS Giotto SPA | 3 |
| CR HD5.0 AEC Cassette | Agfa Healthcare Inc. | 3 |
| Directview CR Mammography Cassette with HR Screen | Carestream Health, Inc. | 3 |
| Carestream CR Mammography Cassette with SNP-M1 Screen | Carestream Health, Inc. | 3 |
Showing 12 of 103. All products under Full Field Digital, System, X-Ray, Mammographic
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K254090 | 2026-09-02 |
| K123873 | 2013-01-29 |
Recalls
5 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2026-04-08 | Class II | Device Design | Complaints have been received of systems developing loose, missing, or broken internal bolts over time. | 4,305 units | |
| 2020-01-21 | Class II | Process control | The recalling firm has received reports from the field of the C-arm on the Selenia Dimensions system seizing or dropping during field repairs and cleaning of the systems. | 72 | 2021-08-11 |
| 2018-12-06 | Class II | Software design | Calibration issue not possible to visualize contrast uptake in the subtracted mammography images | 337 units | 2020-04-24 |
| 2014-05-13 | Class II | Component change control | Selenia Full Field Digital Mammography System defective relay switch, if there is a need to use the emergency off switch, the system may not turn off which could result in patient injury | 11 units | 2014-08-18 |
| 2013-09-06 | Class II | Software design | Software: When the Selenia upon meeting the hard drive threshold of 4,000 images, may delete the most recently dated images | 62 systems | 2013-12-13 |
PMA Approvals
A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.
| PMA number | Decision | Trade name | Approved to |
|---|---|---|---|
| P080018 | 2010-11-03 | KODAK DIRECTVIEW COMPUTED RADIOGRAPHY (CR) MAMMOGRAPHY | Carestream Health, Inc. |
| P050014 | 2009-01-09 | FUJI COMPUTED RADIOGRAPHY MAMMOGRAPHY SUITE | Fujifilm Medical System U.S.A., Inc. |
| P990066 | 2007-08-01 | GE SENOGRAPHE ESSENTIAL FULL FIELD MAMMOGRAPHY SYSYTEM (SENO ESSENTIAL | GE Healthcare GmbH |
| P030010 | 2004-08-20 | SIEMENS MAMMOMAT NOVATIONDR FULL FIELD DIGITAL MAMMOGRAPHY SYSTEM | Siemens Medical Solution |
| P010017 | 2004-05-12 | SENOSCAN FULL FIELD DIGITAL MAMMOGRAPHY SYSTEM | Hologic, Inc. |
| P010025 | 2003-09-24 | SELENIA FULL FIELD DIGITAL MAMMOGRAPHY SYSTEM | Hologic, Inc. |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.