Orthopantomograph OP 3d Pro
6 catalogue numbers from OP300-1, listed by Palodex Group OY, Finland, under X-Ray, Tomography, Computed, Dental. 4 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (2), Guangdong (1), Zhejiang (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Changzhou Sifary Medical Technology Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 14 |
| Fussen Technology Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 3 |
| Yian Medical Technology (Haining) Co., Ltd. | Jiaxing | Zhejiang | Specification developer | 1 |
| Changzhou Finno Medical Technology Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 1 |
Record
| Listed by | Palodex Group OY, Finland |
|---|---|
| FDA product code | OAS |
| Device type | X-Ray, Tomography, Computed, Dental |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1750 |
| Establishment | Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K133544 |
| Record published | 2017-03-31 |
| Record revised | 2018-07-06 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| OP300-1 | In distribution | |
| OP300-1 | In distribution | |
| OP300-1 | In distribution | |
| OP300-1 | In distribution | |
| OP300-1 | In distribution | |
| OP300-1 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Rayscan | RAY Co., Ltd., | 52 |
| Rayscan Studio | RAY Co., Ltd., | 21 |
| Dental CT Scanner AXR | Alliage S/A Indústrias Médico Odontológica | 15 |
| PaX-i3D Green | Vatech Co., Ltd. | 14 |
| Orthopantomograph™ OP 3D | Palodex Group OY | 11 |
| Sleeve for extraoral X-Ray devices | Sirona Dental Systems Gmbh | 11 |
| SXR / Saevo | Alliage S/A Indústrias Médico Odontológica | 11 |
| X-Mind trium | DE Götzen SRL | 10 |
| Genoray | Genoray Co., Ltd. | 9 |
| Rayscan α-Expert3D | RAY Co., Ltd., | 9 |
| Orthophos SL | Sirona Dental Systems Gmbh | 9 |
| Orthophos XG | Sirona Dental Systems Gmbh | 9 |
Showing 12 of 110. All products under X-Ray, Tomography, Computed, Dental
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K241249 | 2024-09-12 |
| K230505 | 2023-06-09 |
| K180947 | 2018-06-07 |
| K163423 | 2017-08-31 |
| K170813 | 2017-04-07 |
| K133544 | 2014-03-26 |
| K130297 | 2013-05-29 |
| K122018 | 2012-12-10 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2021-10-28 | Class II | Radiation Control for Health and Safety Act | It was noticed in production on 28.10.2021, that the final testing database gives a pass result for Pan ADC repeatability test even when the test result is not within the set acceptance criteria (repeatability within 4%). | 103 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.