Orthopantomograph OP 3d Pro

6 catalogue numbers from OP300-1, listed by Palodex Group OY, Finland, under X-Ray, Tomography, Computed, Dental. 4 manufacturers in China are registered for this product code.

Registry build 21.09.26
4manufacturers in China registered for this device type
6catalogue numbers in this listing
8510(k) clearances naming this product code
1recall

Who Else Makes It

Concentrated in Jiangsu (2), Guangdong (1), Zhejiang (1).

Chinese manufacturers registered for FDA product code OAS
Manufacturer City Province Registered as Device types
Changzhou Sifary Medical Technology Co., Ltd. Changzhou Jiangsu Manufacturer 14
Fussen Technology Co., Ltd. Shenzhen Guangdong Manufacturer 3
Yian Medical Technology (Haining) Co., Ltd. Jiaxing Zhejiang Specification developer 1
Changzhou Finno Medical Technology Co., Ltd. Changzhou Jiangsu Manufacturer 1

Record

Regulatory record for Orthopantomograph OP 3D Pro
Listed by Palodex Group OY, Finland
FDA product code OAS
Device type X-Ray, Tomography, Computed, Dental
Device class Class 2
Regulation 21 CFR 892.1750
Establishment Complaint-file establishment, Manufacturer, Exporter
510(k) K133544
Record published 2017-03-31
Record revised 2018-07-06 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for Orthopantomograph OP 3D Pro
Catalogue number Size Status
OP300-1 In distribution
OP300-1 In distribution
OP300-1 In distribution
OP300-1 In distribution
OP300-1 In distribution
OP300-1 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Rayscan RAY Co., Ltd., 52
Rayscan Studio RAY Co., Ltd., 21
Dental CT Scanner AXR Alliage S/A Indústrias Médico Odontológica 15
PaX-i3D Green Vatech Co., Ltd. 14
Orthopantomograph™ OP 3D Palodex Group OY 11
Sleeve for extraoral X-Ray devices Sirona Dental Systems Gmbh 11
SXR / Saevo Alliage S/A Indústrias Médico Odontológica 11
X-Mind trium DE Götzen SRL 10
Genoray Genoray Co., Ltd. 9
Rayscan α-Expert3D RAY Co., Ltd., 9
Orthophos SL Sirona Dental Systems Gmbh 9
Orthophos XG Sirona Dental Systems Gmbh 9

Showing 12 of 110. All products under X-Ray, Tomography, Computed, Dental

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K241249 2024-09-12
K230505 2023-06-09
K180947 2018-06-07
K163423 2017-08-31
K170813 2017-04-07
K133544 2014-03-26
K130297 2013-05-29
K122018 2012-12-10

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2021-10-28 Class II Radiation Control for Health and Safety Act It was noticed in production on 28.10.2021, that the final testing database gives a pass result for Pan ADC repeatability test even when the test result is not within
the set acceptance criteria (repeatability within 4%).
103

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer