T1-C

The T1-C is a dental X-ray system for panoramic and cone-beam CT imaging of the teeth and jaws. It provides diagnostic images for adult and paediatric dentistry, including treatment…

Registry build 21.09.26

The T1-C is a dental X-ray system for panoramic and cone-beam CT imaging of the teeth and jaws. It provides diagnostic images for adult and paediatric dentistry, including treatment planning for oral surgery or implant procedures.

The system combines an X-ray tube, generator and digital detector with a computer and image-viewing software. Rotational X-ray data is reconstructed into three-dimensional oral anatomy, while panoramic mode provides a different dental overview.

Model Scope

T1-C supports panoramic and cone-beam CT modes. Cephalometric imaging is provided by the separate T1-CS configuration and is not part of the T1-C mode set.

4manufacturers in China registered for this device type
1catalogue number
3510(k) clearances naming this product code
3recalls on this code

Who Else Makes It

Concentrated in Jiangsu (2), Guangdong (1), Zhejiang (1).

Chinese manufacturers registered for FDA product code OAS
Manufacturer City Province Registered as Device types
Changzhou Sifary Medical Technology Co., Ltd. Changzhou Jiangsu Manufacturer 14
Fussen Technology Co., Ltd. Shenzhen Guangdong Manufacturer 3
Yian Medical Technology (Haining) Co., Ltd. Jiaxing Zhejiang Specification developer 1
Changzhou Finno Medical Technology Co., Ltd. Changzhou Jiangsu Manufacturer 1

Record

Regulatory record for T1-C
Listed by Osstem Implant Co., Ltd., South Korea
FDA product code OAS
Device type X-Ray, Tomography, Computed, Dental
Device class Class 2
Regulation 21 CFR 892.1750
Establishment Contract manufacturer, Specification developer, Private-label distributor, Complaint-file establishment, Manufacturer, Exporter
510(k) K183475
Record published 2021-04-28

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries lot or batch number, manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for T1-C
Catalogue number Size Status
T1-C In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Rayscan RAY Co., Ltd., 52
Rayscan Studio RAY Co., Ltd., 21
Dental CT Scanner AXR Alliage S/A Indústrias Médico Odontológica 15
PaX-i3D Green Vatech Co., Ltd. 14
Orthopantomograph™ OP 3D Palodex Group OY 11
Sleeve for extraoral X-Ray devices Sirona Dental Systems Gmbh 11
SXR / Saevo Alliage S/A Indústrias Médico Odontológica 11
X-Mind trium DE Götzen SRL 10
Genoray Genoray Co., Ltd. 9
Rayscan α-Expert3D RAY Co., Ltd., 9
Orthophos SL Sirona Dental Systems Gmbh 9
Orthophos XG Sirona Dental Systems Gmbh 9

Showing 12 of 110. All products under X-Ray, Tomography, Computed, Dental

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K233806 2024-09-06
K212303 2021-09-21
K183475 2019-08-30

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of T1-C
Recalled by Identified by Initiated FDA class Root cause Reason
Osstem Implant Co., Ltd. 510(k) number 2025-08-26 Class II Radiation Control for Health and Safety Act Osstem Implant Co. Ltd, is voluntarily initiating a medical device correction involving the current labeling for this electronic product may be missing a required Certification Statement under 21 CFR Subchapter J (Radiological Health Regula

Recalls

2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason
2025-08-26 Class II Radiation Control for Health and Safety Act Osstem Implant Co. Ltd, is voluntarily initiating a medical device correction involving the current labeling for this electronic product may be missing a required Certification Statement under 21 CFR Subchapter J (Radiological Health Regula
2025-08-26 Class II Radiation Control for Health and Safety Act Osstem Implant Co. Ltd, is voluntarily initiating a medical device correction involving the current labeling for this electronic product may be missing a required Certification Statement under 21 CFR Subchapter J (Radiological Health Regula

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer