Tomographic Imager Combining Emission Computed Tomography With Nuclear Magnetic Resonance

GE SIGNA PET/MR is an integrated imaging system that combines magnetic resonance imaging with positron emission tomography. The MR scanner and PET detector acquire complementary image…

Registry build 21.09.26

GE SIGNA PET/MR is an integrated imaging system that combines magnetic resonance imaging with positron emission tomography. The MR scanner and PET detector acquire complementary image information in the same system, supporting anatomical and functional views within a combined examination.

The listed assembly is one configuration in the SIGNA PET/MR family. GE describes simultaneous PET and MR acquisition as a central part of the platform; individual assemblies and field configurations differ across that family.

Listed Item

SIGNA PETMR System Medical Device Assembly – MDR

Imaging Components

The integrated PET detector operates within the MR scanner environment, so PET and MR data are acquired as parts of one imaging workflow. Reconstruction software combines the acquired data into PET/MR image sets.

The entry identifies a system assembly rather than a standalone detector or software package. Model-specific scanner and reconstruction options depend on the assembled configuration.

3manufacturers in China registered for this device type
13catalogue numbers in this listing

Who Else Makes It

Concentrated in Shanghai (1), Guangdong (1), Tianjin (1).

Chinese manufacturers registered for FDA product code OUO
Manufacturer City Province Registered as Device types
Shanghai United Imaging Healthcare Co., Ltd. Shanghai Shanghai Manufacturer 12
Siemens Shenzhen Magnetic Resonance Ltd. Shenzhen Guangdong Contract manufacturer 8
GE Healthcare (Tianjin) Company Limited Tianjin Tianjin Specification developer 5

Record

Regulatory record for Tomographic Imager Combining Emission Computed Tomography With Nuclear Magnetic Resonance
Listed by GE Medical Systems, L.L.C.
FDA product code OUO
Device type Tomographic Imager Combining Emission Computed Tomography With Nuclear Magnetic Resonance
Device class Class 2
Regulation 21 CFR 892.1200
510(k) K142098
Record published 2016-05-16
Record revised 2026-01-30 (version 7)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries lot or batch number, manufacturing date, serial number
Distribution end date 2024-05-26

Catalogue Numbers

Catalogue numbers for Tomographic Imager Combining Emission Computed Tomography With Nuclear Magnetic Resonance
Catalogue number Size Status
5265300-50 In distribution
3.0T UAA In distribution
SIGNA PET MR In distribution
3.0T PETMR CMA In distribution
SIGNA PET MR In distribution
5494440 In distribution
3.0T LAA In distribution
5775930 Withdrawn
MP24 Withdrawn
MP24 R03 Withdrawn
SIGNA PET MR SPiCE Workstation Withdrawn
SIGNA PET MR Withdrawn
5789577 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Symphony™ Qfix 3
Flex small 4 MR coil set 3T Siemens Healthcare Limited 2
Lithotomy AirShuttle™ Qfix 1
ZiFix™ Qfix 1
mMR Head Siemens Healthcare Limited 1
3T Loop 4 cm MR coil kit Siemens Healthcare Limited 1
mMR Head set Siemens Healthcare Limited 1
mMR Head/Neck coil set Siemens Healthcare Limited 1
mMR Head/Neck Matrix coil Siemens Healthcare Limited 1
mMR Body coil set Siemens Healthcare Limited 1
uPMR Shanghai United Imaging Healthcare Co., Ltd. 1
3T Body Matrix MR coil set, Verio Siemens Healthcare Limited 1

Showing 12 of 22. All products under Tomographic Imager Combining Emission Computed Tomography With Nuclear Magnetic Resonance

Recalls Naming This Product

7 recalls name this product by its own identifiers, the UDI on its label or the 510(k) it is cleared under.

Recalls naming the identifiers of Tomographic Imager Combining Emission Computed Tomography With Nuclear Magnetic Resonance
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
GE Medical Systems, LLC UDI-DI 2025-06-20 Class II Equipment maintenance GE HealthCare has become aware that for certain MR systems (SIGNA Artist, SIGNA Voyager, Discovery MR450 1.5T, Optima MR450w 1.5T, SIGNA Architect, SIGNA Premier, SIGNA UHP, Discovery MR750 3.0T, Discovery MR750w 3.0T, SIGNA Hero, SIGNA PET 97 units
GE Medical Systems, LLC UDI-DI 2025-05-23 Class II Device Design GE HealthCare has become aware that gradient coils for certain MR systems (see affected product list in this letter), under specific conditions, can produce elevated acoustic noise during scanning. As a result, acoustic levels can exceed 99
GE Medical Systems, LLC 510(k) number 2024-06-14 Class II Device Design GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met:
1. 2D FSE T2 FLAIR OR T2 FLAIR
123 units
GE Medical Systems, LLC 510(k) number 2021-12-23 Class II Process control The magnetic resonance systems could potentially have a cryogen ventilation system that does not meet the venting requirements. 17,228 devices total in this field correction
GE Medical Systems, LLC 510(k) number 2021-06-04 Class II Software design GE Healthcare has recently become aware of an issue on the affected products listed below where the “Patient Orientation” button may inadvertently be clicked when intending to click on the “Save RX” button. This changes the prescribed pati 71 devices
GE Medical Systems, LLC 510(k) number 2020-09-08 Class II Process change control Potential electrical arc flash within the Power Gradient & RF (PGR) Cabinet. 2021-04-28
GE Medical Systems, LLC 510(k) number 2015-08-31 Class II Software design When performing head or neck scans, the currently displayed SAR values could be lower than the actual SAR in the head as predicted by SAR modeling. The predicted HEAD SAR value from the modeling suggests the actual SAR in the head could exc 17 2018-09-07

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer