AI Metrics
The FDA filing identifies AI Metrics as software for viewing, manipulating, communicating, storing, annotating, analyzing and comparing medical images. It supports CT and MR images and…
The FDA filing identifies AI Metrics as software for viewing, manipulating, communicating, storing, annotating, analyzing and comparing medical images.
It supports CT and MR images and anatomical data sets across multiple imaging modalities and time points.
Listed Item
AI Metrics is a thin client software application used with general purpose computing hardware for the display and visualization of medical image data, supporting images and anatomical datasets, such as CT and MR. AI Metrics is designed as a workflow automation application with analytical tools to help the user assess, categorize and document the extent of a disease and/or tumor response to therapy in accordance with user selected standards (e.g. RECIST 1.1) and assess changes in imaging findings over multiple time-points. AI Metrics supports the interpretation and evaluation of examinations and follow up documentation of findings within healthcare institutions, for example, in Radiology, Oncology, and other Medical Imaging environments. AI Metrics functionality provides for communication, storage, processing, rendering, and display of DICOM compliant image data derived from various sources, navigation through images, selection of regions of interest, generation of information from those regions, evaluation in accordance with user selected standards, and generation of a structured report. The user controls these functions with a system of interactive menus and semi-automated or manual workflow automation tools, including: • Manual annotation tools for users to select regions of interest (ROIs), • Semi-automatic lesion segmentation suggestions for user-selected ROIs, • Automatic measurement and display of long and short axis of segmented lesions, • Automatic tabulation and summation of measurements, • Semi-automatic lesion labelling suggestions for anatomical location (organ, body region, and laterality), • Automatic calculation of quantitative and qualitative metrics using annotation data in accordance with the selected criteria, and • Automatic generation of a structured report that includes the annotation data and calculated quantitative and qualitative metrics presented in a graph, table, key images, and structured text report.
Clinical Workflow
The FDA description identifies AI Metrics as a software-based PACS for displaying and visualizing image data. It provides workflow automation and supports documentation and comparison of image findings over multiple time points; a trained professional interprets the information.
Who Else Makes It
Concentrated in Jiangsu (5), Shanghai (5), Beijing (3). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Shantou Institute OF Ultrasonic Instruments Co., Ltd. | Shantou | Guangdong | Contract manufacturer | 8 |
| iRay Imaging Technology (Haining) Limited | Haining | Zhejiang | Contract manufacturer | 6 |
| Chison Medical Technologies Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 5 |
| Coretronic Projection (Kunshan) Corporation | Kunshan | Jiangsu | Contract manufacturer | 3 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Arthrex (Shanghai) Co., Ltd. | Shanghai | Shanghai | Exporter | 38 |
| GE Hangwei Medical Systems Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| Shanghai United Imaging Healthcare Co., Ltd. | Shanghai | Shanghai | Manufacturer | 12 |
| Siemens Shanghai, Medical Equipment Ltd. | Shanghai | Shanghai | Contract manufacturer | 10 |
| Carestream Health, Inc., Global R&D Center | Shanghai | Shanghai | Specification developer | 8 |
| Beijing Infervision Healthcare Medical Technology Co., Ltd. | Beijing | Beijing | Complaint-file establishment | 4 |
Showing 12 of 16. All 16 manufacturers in China registered for System, Image Processing, Radiological
Record
| Listed by | Ai Metrics, LLC, United States |
|---|---|
| FDA product code | LLZ |
| Device type | System, Image Processing, Radiological |
| Device class | Class 2 |
| Regulation | 21 CFR 892.2050 |
| 510(k) | K202229 |
| Record published | 2021-05-24 |
| Record revised | 2023-10-18 (version 2) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Label carries | lot or batch number, manufacturing date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 1 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Imagegrid Radiology Viewer System | Candelis, Inc. | 173 |
| Tims System | Foresight Imaging, LLC | 159 |
| System, Image Processing, Radiological | Biomet Microfixation | 146 |
| RamSoft | Ramsoft, Inc. | 65 |
| Joints | Medstrat | 62 |
| OrthoView | Meridian Technique Ltd | 54 |
| IPS | KLS-Martin L.P. | 48 |
| NovaPACS | Novarad Corp. | 42 |
| PointCloud Knee Instruments | Unik Orthopedics, Inc | 34 |
| DTX Studio™ Clinic | Nobel Biocare AB | 34 |
| Eaglesoft | Patterson Technology Center | 33 |
| Medtronic Navigation | Medtronic Navigation, Inc. | 26 |
Showing 12 of 1,109. All products under System, Image Processing, Radiological
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K202229 | 2020-12-22 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.