Autoplaque for ORS Visual
Autoplaque is a post-processing add-on module for ORS Visual that provides automated quantification of calcified and non-calcified plaque lesions in coronary arteries from contrasted…
Autoplaque is a post-processing add-on module for ORS Visual that provides automated quantification of calcified and non-calcified plaque lesions in coronary arteries from contrasted coronary CT angiographic studies for the evaluation of cardiovascular disease. Users can automatically segment the section of the coronary artery of interest, or manually input the centerline, to initiate a detailed and robust plaque lesion analysis routine. Analysis by Autoplaque provides biometric information that includes calcified plaque volume, non-calcified plaque volume with possible separation into low and high density non-calcified plaques, stenosis percentage, remodeling index, plaque length measurement, and proximal, distal, and stenosis diameters. If the Autoplaque add-on is used to analyze more than one coronary artery section, the additional parameters of total non-calcified plaque volume, total low density plaque volume, total calcified plaque volume, maximum remodeling index, maximum stenosis percentage, and the maximum plaque length will also be available. ORS Visual is a proprietary software application developed by Object Research Systems (ORS) Inc. that can be is used for the display and 3D visualization of medical image data derived from CT, MRI, and other modalities. It provides for the communication, storage, processing, rendering, and display of DICOM 3.0 compliant image data. ORS Visual, which is available in 32 and 64-bit versions, can be installed on a standard personal computer running the Windows operating system with the Microsoft ActiveX component and suitable graphics hardware.
Who Else Makes It
Concentrated in Jiangsu (5), Shanghai (5), Beijing (3). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Shantou Institute OF Ultrasonic Instruments Co., Ltd. | Shantou | Guangdong | Contract manufacturer | 8 |
| iRay Imaging Technology (Haining) Limited | Haining | Zhejiang | Contract manufacturer | 6 |
| Chison Medical Technologies Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 5 |
| Coretronic Projection (Kunshan) Corporation | Kunshan | Jiangsu | Contract manufacturer | 3 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Arthrex (Shanghai) Co., Ltd. | Shanghai | Shanghai | Exporter | 38 |
| GE Hangwei Medical Systems Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| Shanghai United Imaging Healthcare Co., Ltd. | Shanghai | Shanghai | Manufacturer | 12 |
| Siemens Shanghai, Medical Equipment Ltd. | Shanghai | Shanghai | Contract manufacturer | 10 |
| Carestream Health, Inc., Global R&D Center | Shanghai | Shanghai | Specification developer | 8 |
| Beijing Infervision Healthcare Medical Technology Co., Ltd. | Beijing | Beijing | Complaint-file establishment | 4 |
Showing 12 of 16. All 16 manufacturers in China registered for System, Image Processing, Radiological
Record
| Listed by | Object Research Systems (Ors), Inc., Canada |
|---|---|
| FDA product code | LLZ |
| Device type | System, Image Processing, Radiological |
| Device class | Class 2 |
| Regulation | 21 CFR 892.2050 |
| 510(k) | K122429 |
| Record published | 2016-09-15 |
| Record revised | 2023-10-18 (version 6) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | lot or batch number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| ORS-VISU-AP01 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Imagegrid Radiology Viewer System | Candelis, Inc. | 173 |
| Tims System | Foresight Imaging, LLC | 159 |
| System, Image Processing, Radiological | Biomet Microfixation | 146 |
| RamSoft | Ramsoft, Inc. | 65 |
| Joints | Medstrat | 62 |
| OrthoView | Meridian Technique Ltd | 54 |
| IPS | KLS-Martin L.P. | 48 |
| NovaPACS | Novarad Corp. | 42 |
| PointCloud Knee Instruments | Unik Orthopedics, Inc | 34 |
| DTX Studio™ Clinic | Nobel Biocare AB | 34 |
| Eaglesoft | Patterson Technology Center | 33 |
| Medtronic Navigation | Medtronic Navigation, Inc. | 26 |
Showing 12 of 1,109. All products under System, Image Processing, Radiological
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K122429 | 2012-11-28 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.