ClariCT.AI
ClariCT.AI, is a software device intended for networking, communication, processing and enhancement of CT images in DICOM format regardless of the manufacturer of CT scanner or model. The…
ClariCT.AI, is a software device intended for networking, communication, processing and enhancement of CT images in DICOM format regardless of the manufacturer of CT scanner or model. The original cleared device (K183460) is a software application to denoise on CT images, integrated with the clinical environment through DICOM communication on an on-premise environment, and runs under Microsoft Windows platform. The device consists of Denoise Processing module that denoises CT images and other modules (Window application module) that provide many features such as handling DICOM connection from/to PACS, user interface, worklist management and viewer. The subject device, ClariCT.AI, has added a new module (named Al Marketplace Integration module) to the original cleared device (K183460) to enable installation on the Al Marketplace system. The module integrates the Denoising Processor of original device into the Al Marketplace system and includes an optional multiframe PET-CT module which denoises multiframe PET-CT fusion images included as a series in CT study. ClariCT.AI, consists only of the Al Marketplace Integration Module and the Denoising Processor, can be installed in the Al Marketplace system that integrates centrally with PACS and seamlessly integrates into the existing IT and modality infrastructure. An Al Marketplace system, which can be integrated with the ClariCT.AI, is a cloud-based Al platform service that connects end users (e.g. hospitals, imaging centers) and Al medical imaging applications developed by third parties. These Al Marketplace systems provide many features such as handling DICOM connection from/to PACS, user interface, authentication, worklist control, and orchestrating third party Al applications. With the newly added module, ClariCT.Al will function as a software device integrated with such system, and therefore the responsibility of our software is bound to change so as to take care of only essential functionality such as denoising process and system interface.
Who Else Makes It
Concentrated in Jiangsu (5), Shanghai (5), Beijing (3). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Shantou Institute OF Ultrasonic Instruments Co., Ltd. | Shantou | Guangdong | Contract manufacturer | 8 |
| iRay Imaging Technology (Haining) Limited | Haining | Zhejiang | Contract manufacturer | 6 |
| Chison Medical Technologies Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 5 |
| Coretronic Projection (Kunshan) Corporation | Kunshan | Jiangsu | Contract manufacturer | 3 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Arthrex (Shanghai) Co., Ltd. | Shanghai | Shanghai | Exporter | 38 |
| GE Hangwei Medical Systems Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| Shanghai United Imaging Healthcare Co., Ltd. | Shanghai | Shanghai | Manufacturer | 12 |
| Siemens Shanghai, Medical Equipment Ltd. | Shanghai | Shanghai | Contract manufacturer | 10 |
| Carestream Health, Inc., Global R&D Center | Shanghai | Shanghai | Specification developer | 8 |
| Beijing Infervision Healthcare Medical Technology Co., Ltd. | Beijing | Beijing | Complaint-file establishment | 4 |
Showing 12 of 16. All 16 manufacturers in China registered for System, Image Processing, Radiological
Record
| Listed by | Claripi Inc., South Korea |
|---|---|
| FDA product code | LLZ |
| Device type | System, Image Processing, Radiological |
| Device class | Class 2 |
| Regulation | 21 CFR 892.2050 |
| Establishment | Reprocessor, Specification developer, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K183460 |
| Record published | 2019-12-20 |
| Record revised | 2023-12-04 (version 2) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | lot or batch number, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 1.1.0 | In distribution | |
| ClariPET-CT | In distribution | |
| 1.3.3 | In distribution | |
| ClariCT.ACE | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Imagegrid Radiology Viewer System | Candelis, Inc. | 173 |
| Tims System | Foresight Imaging, LLC | 159 |
| System, Image Processing, Radiological | Biomet Microfixation | 146 |
| RamSoft | Ramsoft, Inc. | 65 |
| Joints | Medstrat | 62 |
| OrthoView | Meridian Technique Ltd | 54 |
| IPS | KLS-Martin L.P. | 48 |
| NovaPACS | Novarad Corp. | 42 |
| PointCloud Knee Instruments | Unik Orthopedics, Inc | 34 |
| DTX Studio™ Clinic | Nobel Biocare AB | 34 |
| Eaglesoft | Patterson Technology Center | 33 |
| Medtronic Navigation | Medtronic Navigation, Inc. | 26 |
Showing 12 of 1,109. All products under System, Image Processing, Radiological
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K203783 | 2022-04-06 |
| K212074 | 2021-07-27 |
| K183460 | 2019-06-13 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.