Iconnect Enterprise Workflow With Merge PACS

Standalone software application. A universal workflow (non-medical tool) on Merge PACS platform.

Registry build 21.09.26
16manufacturers in China registered for this device type
1catalogue number

Who Else Makes It

Concentrated in Jiangsu (5), Shanghai (5), Beijing (3). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code LLZ
Manufacturer City Province Registered as Device types
Shantou Institute OF Ultrasonic Instruments Co., Ltd. Shantou Guangdong Contract manufacturer 8
iRay Imaging Technology (Haining) Limited Haining Zhejiang Contract manufacturer 6
Chison Medical Technologies Co., Ltd. Wuxi Jiangsu Contract manufacturer 5
Coretronic Projection (Kunshan) Corporation Kunshan Jiangsu Contract manufacturer 3
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57
Arthrex (Shanghai) Co., Ltd. Shanghai Shanghai Exporter 38
GE Hangwei Medical Systems Co., Ltd. Beijing Beijing Specification developer 22
Shanghai United Imaging Healthcare Co., Ltd. Shanghai Shanghai Manufacturer 12
Siemens Shanghai, Medical Equipment Ltd. Shanghai Shanghai Contract manufacturer 10
Carestream Health, Inc., Global R&D Center Shanghai Shanghai Specification developer 8
Beijing Infervision Healthcare Medical Technology Co., Ltd. Beijing Beijing Complaint-file establishment 4

Showing 12 of 16. All 16 manufacturers in China registered for System, Image Processing, Radiological

Record

Regulatory record for iConnect Enterprise Workflow with Merge PACS
Listed by Merge Healthcare Solutions Inc.
FDA product code LLZ
Device type System, Image Processing, Radiological
Device class Class 2
Regulation 21 CFR 892.2050
510(k) K082144
Record published 2017-02-22
Record revised 2023-10-18 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries lot or batch number, manufacturing date

Catalogue Numbers

Catalogue numbers for iConnect Enterprise Workflow with Merge PACS
Catalogue number Size Status
1.0 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Imagegrid Radiology Viewer System Candelis, Inc. 173
Tims System Foresight Imaging, LLC 159
System, Image Processing, Radiological Biomet Microfixation 146
RamSoft Ramsoft, Inc. 65
Joints Medstrat 62
OrthoView Meridian Technique Ltd 54
IPS KLS-Martin L.P. 48
NovaPACS Novarad Corp. 42
PointCloud Knee Instruments Unik Orthopedics, Inc 34
DTX Studio™ Clinic Nobel Biocare AB 34
Eaglesoft Patterson Technology Center 33
Medtronic Navigation Medtronic Navigation, Inc. 26

Showing 12 of 1,109. All products under System, Image Processing, Radiological

Recalls Naming This Product

13 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of iConnect Enterprise Workflow with Merge PACS
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Merge Healthcare Incorporated 510(k) number 2017-05-24 Class II Software design (manufacturing process) Studies that have QC, PDE, or HL7 ADT updates applied may fail to propagate via telmed protocol to the destination server and may fail to import on the destination server. 160 sites potentially have the affected versions 2019-10-15
Merge Healthcare Incorporated 510(k) number 2017-05-08 Class II Software design (manufacturing process) Merge PACS did not show unviewed images when the last view was skipped. There is a potential risk to health of a physician misdiagnosis because not all images are available for viewing. 47 sites potentially have the affected versions 2019-08-05
Merge Healthcare Incorporated 510(k) number 2017-05-08 Class II Software design (manufacturing process) When cut lines are shown on an image, the lines may go from being vertical and then shift to horizontal causing confusion to the physician. This may cause a misdiagnosis. 47 sites have the potentially affected versions 2019-08-08
Merge Healthcare Incorporated 510(k) number 2016-04-04 Class II Software design Potential exists for an incorrect patient image being displayed which could result in the delay in diagnosis or treatment. 29 sites have the potentially affected software 2019-04-08
Merge Healthcare Incorporated 510(k) number 2016-04-04 Class II Software design Studies that have QC, PDE, or HL7 ADT updates applied may fail to propagate via telmed protocol to the destination server and may fail to import on the destination server. 248 sites potentially have the affected versions 2021-04-23
Merge Healthcare Incorporated 510(k) number 2016-03-28 Class II Software design The software did not show unviewed images when the last view was skipped. The physician may potentially misdiagnose when not all images are available for viewing. 534 sites potentially have the affected versions 2021-04-23
Merge Healthcare Incorporated 510(k) number 2016-03-28 Class II Component design/selection Cut lines on the image may present horizontally rather than vertically. 537 sites potentially have the affected versions 2021-05-07
Merge Healthcare Incorporated 510(k) number 2016-02-05 Class II Software design When measuring a lesion on an unmagnified mammography image then performing the same measurement on an image magnified by the Hologic imager (different image), the measurements are not the same. 49 sites potentially have the affected versions 2016-10-25
Merge Healthcare Incorporated 510(k) number 2016-01-30 Class II Software design Studies coming over via telmed were missing patient’s DOB, procedure, and referring physician. 109 sites have the affected versions 2019-04-08
Merge Healthcare Incorporated 510(k) number 2016-01-30 Class II Software design A migrated study that has annotations will display the annotations, but when a prior study is loaded that should have annotations, the second study will not display annotations. 208 sites have the affected versions 2021-05-07
Merge Healthcare Incorporated 510(k) number 2016-01-30 Class II Software design The patient name in the Halo title bar and the thumbnails do not match the name on displayed images. 93 sites have the affected version 2020-10-05
Merge Healthcare Incorporated 510(k) number 2016-01-30 Class II Software design Studies that are viewed in iConnect Access that originate on Merge PACS / Ortho PACS may not display the correct current patient demographics if there has been a PDE (Patient / Study Demographic Edit) performed after the images were ingeste 146 sites potentially have the affected versions for both pr 2021-05-07
Merge Healthcare Incorporated 510(k) number 2016-01-30 Class II Software design Studies that are viewed in iConnect Access that originate on Merge PACS / Ortho PACS may not display the correct current patient demographics if there has been a PDE (Patient / Study Demographic Edit) performed after the images were ingeste 146 sites may have the affected version for both products 2021-05-07

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer