ImagePilot

6 catalogue numbers from V1.93R00E, listed by Konica Minolta, Inc., Japan, under System, Image Processing, Radiological. 16 manufacturers in China are registered for this product code.

Registry build 21.09.26
16manufacturers in China registered for this device type
6catalogue numbers in this listing
6510(k) clearances naming this product code

Who Else Makes It

Concentrated in Jiangsu (5), Shanghai (5), Beijing (3). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code LLZ
Manufacturer City Province Registered as Device types
Shantou Institute OF Ultrasonic Instruments Co., Ltd. Shantou Guangdong Contract manufacturer 8
iRay Imaging Technology (Haining) Limited Haining Zhejiang Contract manufacturer 6
Chison Medical Technologies Co., Ltd. Wuxi Jiangsu Contract manufacturer 5
Coretronic Projection (Kunshan) Corporation Kunshan Jiangsu Contract manufacturer 3
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57
Arthrex (Shanghai) Co., Ltd. Shanghai Shanghai Exporter 38
GE Hangwei Medical Systems Co., Ltd. Beijing Beijing Specification developer 22
Shanghai United Imaging Healthcare Co., Ltd. Shanghai Shanghai Manufacturer 12
Siemens Shanghai, Medical Equipment Ltd. Shanghai Shanghai Contract manufacturer 10
Carestream Health, Inc., Global R&D Center Shanghai Shanghai Specification developer 8
Beijing Infervision Healthcare Medical Technology Co., Ltd. Beijing Beijing Complaint-file establishment 4

Showing 12 of 16. All 16 manufacturers in China registered for System, Image Processing, Radiological

Record

Regulatory record for ImagePilot
Listed by Konica Minolta, Inc., Japan
FDA product code LLZ
Device type System, Image Processing, Radiological
Device class Class 2
Regulation 21 CFR 892.2050
Establishment Specification developer, Complaint-file establishment, Manufacturer
510(k) K071436
Record published 2021-11-06
Record revised 2023-10-18 (version 7)

Specifications

Specifications
MRI safety MR Unsafe
Prescription Prescription only
Label carries serial number

Catalogue Numbers

Catalogue numbers for ImagePilot
Catalogue number Size Status
V1.93R00E In distribution
V1.92R00E In distribution
V1.95 In distribution
V1.94R00E In distribution
D9MA In distribution
V1.96R01E In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Imagegrid Radiology Viewer System Candelis, Inc. 173
Tims System Foresight Imaging, LLC 159
System, Image Processing, Radiological Biomet Microfixation 146
RamSoft Ramsoft, Inc. 65
Joints Medstrat 62
OrthoView Meridian Technique Ltd 54
IPS KLS-Martin L.P. 48
NovaPACS Novarad Corp. 42
PointCloud Knee Instruments Unik Orthopedics, Inc 34
DTX Studio™ Clinic Nobel Biocare AB 34
Eaglesoft Patterson Technology Center 33
Medtronic Navigation Medtronic Navigation, Inc. 26

Showing 12 of 1,109. All products under System, Image Processing, Radiological

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K240281 2024-05-31
K230906 2023-04-25
K212685 2021-09-13
K210066 2021-05-06
K182431 2018-11-26
K133730 2014-01-31

Recalls Naming This Product

2 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of ImagePilot
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Konica Minolta Healthcare Americas, Inc 510(k) number 2021-12-03 Class II Under Investigation by firm lmagePilot versions 1.92 and 1.93 paired with an AeroDR or Momentum Panel potential risk of incorrect length measurement/area calculation if incorrect power sequence is followed 30 units 2024-01-05
Konica Minolta Medical Imaging USA, Inc. 510(k) number 2018-05-09 Class II Unknown/Undetermined by firm Panasonic has issued a Mandatory Product Safety Notice, indicating a possibility of battery ignition (fire) in CF-C2 “Toughbook” laptops. Since Konica Minolta uses this laptop in some of its product configurations, it notified its customers 2020-04-10

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer