Merge Cardio V11.1

Catalogue number 11.1, listed by Merge Healthcare Solutions Inc., under System, Image Processing, Radiological. 16 manufacturers in China are registered for this product code.

Registry build 21.09.26
16manufacturers in China registered for this device type
1catalogue number

Who Else Makes It

Concentrated in Jiangsu (5), Shanghai (5), Beijing (3). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code LLZ
Manufacturer City Province Registered as Device types
Shantou Institute OF Ultrasonic Instruments Co., Ltd. Shantou Guangdong Contract manufacturer 8
iRay Imaging Technology (Haining) Limited Haining Zhejiang Contract manufacturer 6
Chison Medical Technologies Co., Ltd. Wuxi Jiangsu Contract manufacturer 5
Coretronic Projection (Kunshan) Corporation Kunshan Jiangsu Contract manufacturer 3
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57
Arthrex (Shanghai) Co., Ltd. Shanghai Shanghai Exporter 38
GE Hangwei Medical Systems Co., Ltd. Beijing Beijing Specification developer 22
Shanghai United Imaging Healthcare Co., Ltd. Shanghai Shanghai Manufacturer 12
Siemens Shanghai, Medical Equipment Ltd. Shanghai Shanghai Contract manufacturer 10
Carestream Health, Inc., Global R&D Center Shanghai Shanghai Specification developer 8
Beijing Infervision Healthcare Medical Technology Co., Ltd. Beijing Beijing Complaint-file establishment 4

Showing 12 of 16. All 16 manufacturers in China registered for System, Image Processing, Radiological

Record

Regulatory record for Merge Cardio V11.1
Listed by Merge Healthcare Solutions Inc.
FDA product code LLZ
Device type System, Image Processing, Radiological
Device class Class 2
Regulation 21 CFR 892.2050
510(k) K051649
Record published 2019-04-17
Record revised 2019-05-09 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries lot or batch number, manufacturing date

Catalogue Numbers

Catalogue numbers for Merge Cardio V11.1
Catalogue number Size Status
11.1 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Imagegrid Radiology Viewer System Candelis, Inc. 173
Tims System Foresight Imaging, LLC 159
System, Image Processing, Radiological Biomet Microfixation 146
RamSoft Ramsoft, Inc. 65
Joints Medstrat 62
OrthoView Meridian Technique Ltd 54
IPS KLS-Martin L.P. 48
NovaPACS Novarad Corp. 42
PointCloud Knee Instruments Unik Orthopedics, Inc 34
DTX Studio™ Clinic Nobel Biocare AB 34
Eaglesoft Patterson Technology Center 33
Medtronic Navigation Medtronic Navigation, Inc. 26

Showing 12 of 1,109. All products under System, Image Processing, Radiological

Recalls Naming This Product

17 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Merge Cardio V11.1
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Merge Healthcare Incorporated 510(k) number 2025-02-19 Class II Software design When following a specific less typical workflow in which the user remeasures using the ultrasound device or manually edits primitive or derived measurement values directly in Clinical Reporting, derived measurements may be inconsistent with 2
Merge Healthcare Incorporated 510(k) number 2025-02-19 Class II Software design When following a specific less typical workflow in which the user remeasures using the ultrasound device or manually edits primitive or derived measurement values directly in Clinical Reporting, derived measurements may be inconsistent with 11
Merge Healthcare Incorporated 510(k) number 2025-02-19 Class II Software design When following a specific less typical workflow in which the user remeasures using the ultrasound device or manually edits primitive or derived measurement values directly in Clinical Reporting, derived measurements may be inconsistent with 66
Merge Healthcare Incorporated 510(k) number 2025-02-19 Class II Software design When following a specific less typical workflow in which the user remeasures using the ultrasound device or manually edits primitive or derived measurement values directly in Clinical Reporting, derived measurements may be inconsistent with 37
Merge Healthcare Incorporated 510(k) number 2020-05-08 Class II Software Design Change An error in the calculation of the Michigan Reference Ranges can generate an inaccurate Z-Score calculation. The error may reduce the sensitivity of the Z-Score in detecting an abnormality resulting in a false negative. 62 units 2023-06-23
Merge Healthcare Incorporated 510(k) number 2016-04-13 Class II Software design Fetal patient report was automatically pulling prior measurement data for a prior fetus since the fetal study is based on the mother’s MRN, resulting in the wrong fetal measurements getting referenced. 30 sites have the potentially affected software versions 2017-07-17
Merge Healthcare Incorporated 510(k) number 2016-04-04 Class II Software design When taking measurements from images on the Cardio workstation or from the US cart, numbers are not crossing to the report in the correct unit of measure. 110 sites potentially have the affected versions 2019-07-26
Merge Healthcare Incorporated 510(k) number 2016-04-04 Class II Software design A situation can occur allowing two physicians to access the same study report in EchoIMS when launched from the Cardio Study List without receiving the read-only notification prompt. 17 sites potentially have the affected versions 2017-03-20
Merge Healthcare Incorporated 510(k) number 2016-04-04 Class II Software design Cardio study list does not show STAT studies without refreshing. 217 sites potentially have the affected versions 2019-07-26
Merge Healthcare Incorporated 510(k) number 2016-03-28 Class II Software design If images are sent without an order in the system, they will be matched with the latest order on the current patient/modality matching potentially resulting in the matching of the report to the incorrect accession number (but still associat 198 sites potentially have the effected versions 2020-03-20
Merge Healthcare Incorporated 510(k) number 2016-03-28 Class II Software design If a reader selects Multi-study review prior to the original study completing its loading process and then immediately returns to image review of the original study, it is possible that not all current images will be present for review, whi 188 sites potentially have the effected versions 2019-04-08
Merge Healthcare Incorporated 510(k) number 2016-02-09 Class II Software design A report can be confirmed with the incorrect patient demographics resulting in it being saved under the incorrect patient record in the Electronic Medical Record (EMR). 116 customers potentially have the affected versions 2017-08-24
Merge Healthcare Incorporated 510(k) number 2016-01-30 Class II Software design Patient information in the header is only found on the first page of the report and not on the subsequent pages. 42 sites potentially have the affected version 2017-12-15
Merge Healthcare Incorporated 510(k) number 2015-10-26 Class II Process control The firm, Merge Healthcare, sent out Merge HEMO V10.0 & Merge CARDIO V10.1 software to 3 customers before the product was completely validated in house. 1 2016-07-22
Merge Healthcare Incorporated 510(k) number 2015-10-01 Class II Software design Reporting feature times out after inactivity for more than an hour sending the user back to the study list, which causes all reporting data being entered to be lost. 116 sites potentially have the effected versions 2018-03-23
Merge Healthcare Incorporated 510(k) number 2015-09-22 Class II Process design For sites using the Issuer of Patient ID (IPID), the system will display the study list and images from different patients with different IPIDs as though they are for the same patient if they all have the first name, last name, and medical 16 sites were originally identified as potentially having th 2017-04-18
Merge Healthcare Incorporated 510(k) number 2015-09-22 Class II Software design Users can merge a device import file with an image study that already has a confirmed report, which may result in including information not present at the time of physician interpretation. 89 sites potentially have the affected software 2019-08-08

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer