Synapse Enterprise Viewer

Synapse Enterprise Viewer (EV) is a software-based enterprise image viewer used with general purpose servers and dedicated reading workstations. It allows for communication, reformatting,…

Registry build 21.09.26

Synapse Enterprise Viewer (EV) is a software-based enterprise image viewer used with general purpose servers and dedicated reading workstations. It allows for communication, reformatting, rendering on the server component and communication and display of DICOM and non-DICOM images as well as reports.

16manufacturers in China registered for this device type
1catalogue number
20recalls on this code

Who Else Makes It

Concentrated in Jiangsu (5), Shanghai (5), Beijing (3). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code LLZ
Manufacturer City Province Registered as Device types
Shantou Institute OF Ultrasonic Instruments Co., Ltd. Shantou Guangdong Contract manufacturer 8
iRay Imaging Technology (Haining) Limited Haining Zhejiang Contract manufacturer 6
Chison Medical Technologies Co., Ltd. Wuxi Jiangsu Contract manufacturer 5
Coretronic Projection (Kunshan) Corporation Kunshan Jiangsu Contract manufacturer 3
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57
Arthrex (Shanghai) Co., Ltd. Shanghai Shanghai Exporter 38
GE Hangwei Medical Systems Co., Ltd. Beijing Beijing Specification developer 22
Shanghai United Imaging Healthcare Co., Ltd. Shanghai Shanghai Manufacturer 12
Siemens Shanghai, Medical Equipment Ltd. Shanghai Shanghai Contract manufacturer 10
Carestream Health, Inc., Global R&D Center Shanghai Shanghai Specification developer 8
Beijing Infervision Healthcare Medical Technology Co., Ltd. Beijing Beijing Complaint-file establishment 4

Showing 12 of 16. All 16 manufacturers in China registered for System, Image Processing, Radiological

Record

Regulatory record for Synapse Enterprise Viewer
Listed by Fujifilm Healthcare Americas Corporation, United States
FDA product code LLZ
Device type System, Image Processing, Radiological
Device class Class 2
Regulation 21 CFR 892.2050
Establishment Specification developer, Repacker / relabeller, Manufacturer
510(k) K183248
Record published 2019-05-23
Record revised 2022-01-24 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information

Catalogue Numbers

Catalogue numbers for Synapse Enterprise Viewer
Catalogue number Size Status
Synapse Enterprise Viewer In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Imagegrid Radiology Viewer System Candelis, Inc. 173
Tims System Foresight Imaging, LLC 159
System, Image Processing, Radiological Biomet Microfixation 146
RamSoft Ramsoft, Inc. 65
Joints Medstrat 62
OrthoView Meridian Technique Ltd 54
IPS KLS-Martin L.P. 48
NovaPACS Novarad Corp. 42
PointCloud Knee Instruments Unik Orthopedics, Inc 34
DTX Studio™ Clinic Nobel Biocare AB 34
Eaglesoft Patterson Technology Center 33
Medtronic Navigation Medtronic Navigation, Inc. 26

Showing 12 of 1,109. All products under System, Image Processing, Radiological

Recalls

18 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2026-07-22 Class II Software design Software issue may cause the ruler measurement to be inaccurate. 6 units
2025-02-11 Class II Software change control The incorrect computed patient age is showing in VX for patients less than 3 months old. 104 units (69 US, 35 OUS)
2024-01-10 Class II Software design Measurements on a Secondary Capture 2D image, that does not have pixel spacing in the DICOM header, when combined with a Breast Tomo Series results in incorrect measurements. 35 Units (28 US, 7 OUS)
2024-01-10 Class II Software design Measurements on a Secondary Capture 2D image, that does not have pixel spacing in the DICOM header, when combined with a Breast Tomo Series results in incorrect measurements. 22 units (22 OUS)
2024-01-10 Class II Software design Measurements on a Secondary Capture 2D image, that does not have pixel spacing in the DICOM header, when combined with a Breast Tomo Series results in incorrect measurements. 64 Units (44 US, 20 OUS)
2024-01-10 Class II Software design Measurements on a Secondary Capture 2D image, that does not have pixel spacing in the DICOM header, when combined with a Breast Tomo Series results in incorrect measurements. 3 Units (3 US)
2024-01-10 Class II Software design Measurements on a Secondary Capture 2D image, that does not have pixel spacing in the DICOM header, when combined with a Breast Tomo Series results in incorrect measurements. 12 Units (12 US)
2024-01-10 Class II Software design Measurements on a Secondary Capture 2D image, that does not have pixel spacing in the DICOM header, when combined with a Breast Tomo Series results in incorrect measurements. 19 Units (7 US, 12 OUS)
2024-01-03 Class II Software design The LV Mass (2D Bullet) equation may be calculated incorrectly, resulting in a variance in the mass of the left ventricle (LV Mass). If used as a main factor for diagnosis, there is a risk of misdiagnosis or incorrect treatment plan of a pa 13
2024-01-03 Class II Software design The LV Mass (2D Bullet) equation may be calculated incorrectly, resulting in a variance in the mass of the left ventricle (LV Mass). If used as a main factor for diagnosis, there is a risk of misdiagnosis or incorrect treatment plan of a pa 8
2021-04-30 Class II Software design Software versions 6.0.4 to 6.2.1 using Advanced Reporting -possibility that a previously assigned internal patient database ID can be reused for a new patient. It was discovered that this value does not increase when a patient merge activi 44 US and 4 OUS 2024-07-29
2021-03-02 Class II Software design The wrong patient information may be displayed in the viewer or PowerJacket. 839 systems
2020-12-11 Class II Software change control The software does not update measurements and calculations in the Clinical Reporting Application (CRA) when the ventricular trace is changed in the study by a different user. 1 unit 2021-11-17
2020-09-11 Class II Software change control FUJIFILM has become aware of the possibility that certain CT studies may report a much higher 3D Sphere MAX value than expected. This issue is specific to 3D Sphere – other density tools are not affected. 1 2021-11-17
2020-09-11 Class II Device Design There is a potential for the wrong patient information may be displayed in the viewer or PowerJacket. Additionally, the incorrect max standard uptake values (SUV) for PET ad CT studies may be returned for Siemens Modality. 235
2020-05-22 Class II Software design Lateromedial (LM) and Lateromedial Oblique (LMO) Orientation Markers may be displayed incorrectly on the 3D TOMO slider bar. In addition, the slice location of the image and/or the slice direction could be incorrect as well, and result in m 135 units
2016-09-15 Class II Software design Image data for a patients image may not be correct 251 units 2019-02-20
2016-05-10 Class II Software design Synapse cannot display image files, DICOM SR files, and/or Annotation files. The “Image Not Loaded” message displays instead 27 units 2019-02-20
2006-02-03 Not classified Other Image orientation and orientation markers may not match when an image is rotated or flipped when the CT Image is preset. 179 units 2012-03-16
2003-05-12 Not classified Other Synapse Version 2.2.1 and 2.3.1 Software [Free-Hand Region] may lead to incorrect density calculations during CT scan 54 units 2004-05-25

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer