Syngo X Workplace
2 catalogue numbers from 10281299, listed by Siemens Healthcare Limited, Canada, under System, Image Processing, Radiological. 16 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (5), Shanghai (5), Beijing (3). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Shantou Institute OF Ultrasonic Instruments Co., Ltd. | Shantou | Guangdong | Contract manufacturer | 8 |
| iRay Imaging Technology (Haining) Limited | Haining | Zhejiang | Contract manufacturer | 6 |
| Chison Medical Technologies Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 5 |
| Coretronic Projection (Kunshan) Corporation | Kunshan | Jiangsu | Contract manufacturer | 3 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Arthrex (Shanghai) Co., Ltd. | Shanghai | Shanghai | Exporter | 38 |
| GE Hangwei Medical Systems Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| Shanghai United Imaging Healthcare Co., Ltd. | Shanghai | Shanghai | Manufacturer | 12 |
| Siemens Shanghai, Medical Equipment Ltd. | Shanghai | Shanghai | Contract manufacturer | 10 |
| Carestream Health, Inc., Global R&D Center | Shanghai | Shanghai | Specification developer | 8 |
| Beijing Infervision Healthcare Medical Technology Co., Ltd. | Beijing | Beijing | Complaint-file establishment | 4 |
Showing 12 of 16. All 16 manufacturers in China registered for System, Image Processing, Radiological
Record
| Listed by | Siemens Healthcare Limited, Canada |
|---|---|
| FDA product code | LLZ |
| Device type | System, Image Processing, Radiological |
| Device class | Class 2 |
| Regulation | 21 CFR 892.2050 |
| Establishment | Contract manufacturer, Manufacturer, Exporter |
| 510(k) | K042995 |
| Record published | 2016-09-24 |
| Record revised | 2021-11-17 (version 7) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | serial number |
| Storage | Special storage condition: Not Condensing; Handling environment temperature 10 to 35 °C; Handling environment atmospheric pressure 70 to 106 KiloPascal; Storage environment temperature -20 to 60 °C; Storage environment humidity 10 to 95 % RH; Storage environment atmospheric pressure 70 to 106 KiloPascal |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 10281299 | In distribution | |
| 10502522 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Imagegrid Radiology Viewer System | Candelis, Inc. | 173 |
| Tims System | Foresight Imaging, LLC | 159 |
| System, Image Processing, Radiological | Biomet Microfixation | 146 |
| RamSoft | Ramsoft, Inc. | 65 |
| Joints | Medstrat | 62 |
| OrthoView | Meridian Technique Ltd | 54 |
| IPS | KLS-Martin L.P. | 48 |
| NovaPACS | Novarad Corp. | 42 |
| PointCloud Knee Instruments | Unik Orthopedics, Inc | 34 |
| DTX Studio™ Clinic | Nobel Biocare AB | 34 |
| Eaglesoft | Patterson Technology Center | 33 |
| Medtronic Navigation | Medtronic Navigation, Inc. | 26 |
Showing 12 of 1,109. All products under System, Image Processing, Radiological
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K252608 | 2025-09-09 |
| K240294 | 2024-05-23 |
| K232744 | 2023-12-21 |
| K230561 | 2023-03-21 |
| K230196 | 2023-02-13 |
| K221501 | 2022-10-14 |
| K213665 | 2022-06-21 |
| K201477 | 2020-07-01 |
| K191040 | 2019-05-16 |
| K182208 | 2018-09-07 |
| K180563 | 2018-04-25 |
| K173378 | 2017-11-20 |
| K171053 | 2017-06-01 |
| K161685 | 2016-07-11 |
| K150843 | 2015-04-24 |
| K132532 | 2013-12-09 |
| K123375 | 2012-11-20 |
| K043122 | 2005-02-09 |
| K992925 | 1999-11-23 |
Recalls Naming This Product
2 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Siemens Medical Solutions USA, Inc. | 510(k) number | 2016-02-24 | Class II | Software design | After importing, the segmentation results appear mirrored at the CARTO system and can’t be used for the ablation procedure. | 6 | 2017-02-16 |
| Siemens Medical Solutions USA, Inc. | 510(k) number | 2015-11-18 | Class II | Software design | Potential post-processing software issue when using tabcard “4D” on X-Workplace with software version VD10E. A too small measurement in the MPRs of a volume when images are acquired with a CT scanner with a tilted gantry. In a 2×2 layout, t | 73 units | 2016-12-05 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.