Vessel Analysis for ORS Visual
Vessel Analysis is a post-processing add-on module for ORS Visual that enables radiologists, cardiologists, vascular surgeons, and interventionalists to quickly and confidently evaluate CT…
Vessel Analysis is a post-processing add-on module for ORS Visual that enables radiologists, cardiologists, vascular surgeons, and interventionalists to quickly and confidently evaluate CT angiographic studies. Vessel Analysis provides stenosis calculations, aneurysm quantification, and stent and stent-graft planning of the aorta, carotid, and renal arteries in an easy-to-use, intuitive screen that can simplify the clinical task of planning endovascular procedures. Advanced functionality such as automated vessel finding acts as a baseline for accurate vessel measurements and permits rapid segmentation of vessels. ORS Visual is a proprietary software application developed by Object Research Systems (ORS) Inc. that can be is used for the display and 3D visualization of medical image data derived from CT, MRI, and other modalities. It provides for the communication, storage, processing, rendering, and display of DICOM 3.0 compliant image data. ORS Visual, which is available in 32 and 64-bit versions, can be installed on a standard personal computer running the Windows operating system with the Microsoft ActiveX component and suitable graphics hardware.
Who Else Makes It
Concentrated in Jiangsu (5), Shanghai (5), Beijing (3). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Shantou Institute OF Ultrasonic Instruments Co., Ltd. | Shantou | Guangdong | Contract manufacturer | 8 |
| iRay Imaging Technology (Haining) Limited | Haining | Zhejiang | Contract manufacturer | 6 |
| Chison Medical Technologies Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 5 |
| Coretronic Projection (Kunshan) Corporation | Kunshan | Jiangsu | Contract manufacturer | 3 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Arthrex (Shanghai) Co., Ltd. | Shanghai | Shanghai | Exporter | 38 |
| GE Hangwei Medical Systems Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| Shanghai United Imaging Healthcare Co., Ltd. | Shanghai | Shanghai | Manufacturer | 12 |
| Siemens Shanghai, Medical Equipment Ltd. | Shanghai | Shanghai | Contract manufacturer | 10 |
| Carestream Health, Inc., Global R&D Center | Shanghai | Shanghai | Specification developer | 8 |
| Beijing Infervision Healthcare Medical Technology Co., Ltd. | Beijing | Beijing | Complaint-file establishment | 4 |
Showing 12 of 16. All 16 manufacturers in China registered for System, Image Processing, Radiological
Record
| Listed by | Object Research Systems (Ors), Inc., Canada |
|---|---|
| FDA product code | LLZ |
| Device type | System, Image Processing, Radiological |
| Device class | Class 2 |
| Regulation | 21 CFR 892.2050 |
| 510(k) | K122429 |
| Record published | 2016-09-15 |
| Record revised | 2023-10-18 (version 6) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | lot or batch number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| ORS-VISU-VA01 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Imagegrid Radiology Viewer System | Candelis, Inc. | 173 |
| Tims System | Foresight Imaging, LLC | 159 |
| System, Image Processing, Radiological | Biomet Microfixation | 146 |
| RamSoft | Ramsoft, Inc. | 65 |
| Joints | Medstrat | 62 |
| OrthoView | Meridian Technique Ltd | 54 |
| IPS | KLS-Martin L.P. | 48 |
| NovaPACS | Novarad Corp. | 42 |
| PointCloud Knee Instruments | Unik Orthopedics, Inc | 34 |
| DTX Studio™ Clinic | Nobel Biocare AB | 34 |
| Eaglesoft | Patterson Technology Center | 33 |
| Medtronic Navigation | Medtronic Navigation, Inc. | 26 |
Showing 12 of 1,109. All products under System, Image Processing, Radiological
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K122429 | 2012-11-28 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.