CINA is a radiological computer-assisted triage and notification software device. The software system is based on algorithm-programmed components and is comprised of a standard…
CINA is a radiological computer-assisted triage and notification software device. The software system is based on algorithm-programmed components and is comprised of a standard off-the-shelf operating system and additional image processing applications. DICOM images are received, recorded and filtered before processing. The series are processed chronologically by running algorithms on each series to detect suspicious results of an intracranial hemorrhage (ICH) or a large vessel occlusion (LVO), then notifications on the flagged series are sent to the Worklist Application. The Worklist Application (on premise) displays the pop-up notifications of new studies with suspected findings when they come in, and provides both active and passive notifications. Active notifications are in the form of a small pop-up containing patient name, accession number and the type of suspected findings (ICH or LVO). All the non-enhanced head CT images and head CT angiographies studies received by CINA device are displayed in the worklist and those on which the algorithms have detected a suspected finding (ICH or LVO) are marked with an icon (i.e., passive notification). In addition, a compressed, small black and white image that is marked “not for diagnostic use” is displayed as a preview function. This compressed preview is meant for informational purposes only, does not contain any marking of the findings, and is not intended for primary diagnosis beyond notification. Presenting the radiologist with notification facilitates earlier triage by allowing one to prioritize images in the PACS. Thus, the suspect case receives attention earlier than would have been the case in the standard of care practice alone.
Who Else Makes It
Registered in Beijing.
Record
Regulatory record for Cina | Listed by | Avicenna.ai, France |
| FDA product code | QAS |
| Device type | Radiological Computer-Assisted Triage And Notification Software |
| Device class | Class 2 |
| Regulation | 21 CFR 892.2080 |
| Establishment | Complaint-file establishment, Manufacturer |
| 510(k) | K200855 |
| Record published | 2020-12-14 |
| Record revised | 2023-12-04 (version 5) |
Specifications
Specifications | MRI safety | Labeling does not contain MRI Safety Information |
| Prescription | Prescription only |
| Label carries | lot or batch number |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.