Extend Frame System
Extend Mouth Piece XL P2 (1PCS)
3manufacturers in China registered for this device type
23catalogue numbers in this listing
13510(k) clearances naming this product code
1recall
Who Else Makes It
Concentrated in Shaanxi (1), Guangdong (1), Hubei (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| OUR United Corporation | Xian | Shaanxi | Contract manufacturer | 2 |
| Masep Medical Science & Technology DEVELOPMENT(SHENZHEN)Co. | Shenzhen | Guangdong | Manufacturer | 2 |
| OUR SMD Medical (Wuhan) Co., Ltd. | Wuhan | Hubei | Contract manufacturer | 1 |
Record
| Listed by | Elekta Instrument AB, Sweden |
|---|---|
| FDA product code | IWB |
| Device type | System, Radiation Therapy, Radionuclide |
| Device class | Class 2 |
| Regulation | 21 CFR 892.5750 |
| Record published | 2016-09-23 |
| Record revised | 2025-04-30 (version 6) |
Specifications
| MRI safety | MR Unsafe |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, expiry date |
| Storage | Storage environment temperature 5 to 27 °C |
| Packaging | Pack of 2 |
| Distribution end date | 2025-04-29 |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| 1013559 | 3 | Withdrawn | |
| 1526872 | Withdrawn | ||
| 1019183 | Withdrawn | ||
| 1526870 | Withdrawn | ||
| 1526866 | Withdrawn | ||
| 1009632 | Withdrawn | ||
| 1509087 | Withdrawn | ||
| 1017324 | 3 | Withdrawn | |
| 1017450 | 10 | Withdrawn | |
| 1526879 | Withdrawn | ||
| 1526868 | Withdrawn | ||
| 1017322 | Withdrawn | ||
| 1526874 | Withdrawn | ||
| 1024366 | Withdrawn | ||
| 1018667 | Withdrawn | ||
| 1019178 | Withdrawn | ||
| 1009630 | Withdrawn | ||
| 1018275 | Withdrawn | ||
| 1526877 | Withdrawn | ||
| 1526861 | Withdrawn | ||
| 1051520 | Withdrawn | ||
| 1011049 | Withdrawn | ||
| 1526875 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| GammaPod™ Breast Immobilization and Localization System | Xcision Medical Systems, LLC | 42 |
| Clarity® | Elekta Solutions AB | 11 |
| Leksell Gamma Knife Icon | Elekta Instrument AB | 9 |
| Leksell Gamma Knife Perfexion/Icon | Elekta Instrument AB | 9 |
| Leksell Gamma Knife Perfexion/Icon | Elekta Solutions AB | 5 |
| Leksell Gamma Knife Icon | Elekta Solutions AB | 4 |
| GammaBeam | Best Theratronics Ltd. | 2 |
| Leksell Gamma Knife C 4 4C | Elekta Instrument AB | 2 |
| Isorad Detector, 15-25MV (-) 3m | Sun Nuclear Corporation | 2 |
| Leksell GammaPlan | Elekta Solutions AB | 2 |
| 15-25 MV Isorad Detector (3m Cable) | Sun Nuclear Corporation | 2 |
| Isorad Detector, 6-12MV (+) 3m | Sun Nuclear Corporation | 2 |
Showing 12 of 33. All products under System, Radiation Therapy, Radionuclide
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K173789 | 2018-03-30 |
| K173791 | 2018-02-09 |
| K160440 | 2016-04-20 |
| K151159 | 2015-10-29 |
| K151561 | 2015-08-04 |
| K133565 | 2014-05-09 |
| K120811 | 2012-05-24 |
| K092083 | 2009-09-22 |
| K063512 | 2007-03-05 |
| K061941 | 2006-08-21 |
| K061540 | 2006-07-05 |
| K051022 | 2005-06-01 |
| K984328 | 1999-05-21 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2018-06-27 | Class II | Software design | The margin tool in Leksell GammaPlan 11.1 systematically overestimates margin in certain areas of the volume. | 52 devices |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.