Adjustable Arm for Param. Modules

Catalogue number 6676960, listed by Maquet Critical Care AB, Sweden, under Gas-Machine, Anesthesia. 4 manufacturers in China are registered for this product code.

Registry build 21.09.26
4manufacturers in China registered for this device type
1catalogue number
5510(k) clearances naming this product code
1recall

Who Else Makes It

Concentrated in Guangdong (2), Jiangsu (1), Hebei (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code BSZ
Manufacturer City Province Registered as Device types
Beijing Aeonmed Co., Ltd. Sanhe Hebei Contract manufacturer 7
Shenzhen Prunus Medical Co., Ltd. Shenzhen Guangdong Contract manufacturer 1
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57

Record

Regulatory record for Adjustable arm for param. modules
Listed by Maquet Critical Care AB, Sweden
FDA product code BSZ
Device type Gas-Machine, Anesthesia
Device class Class 2
Regulation 21 CFR 868.5160
Establishment Specification developer, Complaint-file establishment, Manufacturer, Exporter
510(k) K133958
Record published 2016-10-04
Record revised 2018-07-06 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Label carries lot or batch number

Catalogue Numbers

Catalogue numbers for Adjustable arm for param. modules
Catalogue number Size Status
6676960 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
A9800 Anesthesia Workstation Oricare Inc. 22
Analgesia GAS Mixer, Digital MDM Delivery System Parker Hannifin Corp. 12
Aladin2 Datex-Ohmeda, Inc. 12
Penlon Penlon Ltd. 7
Analgesia GAS Mixer, MDM Delivery System Parker Hannifin Corp. 6
Codonics SLS500i Operating Software Codonics, Inc. 4
Codonics Safe Label System®(SLS) 500i Point of Care Station Codonics, Inc. 4
Spacelabs Healthcare Spacelabs Healthcare (Washington), Inc 4
Codonics Safe Label System®(SLS) 550i Point of Care Station – 144C Codonics, Inc. 3
Aestiva Datex-Ohmeda, Inc. 2
Aisys Datex-Ohmeda, Inc. 2
Infinium Medical Inc. Infinium Medical, Inc. 2

Showing 12 of 293. All products under Gas-Machine, Anesthesia

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K191027 2020-03-18
K160665 2017-03-29
K133958 2014-03-20
K112114 2012-01-13
K102182 2011-05-09

Recalls Naming This Product

8 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Adjustable arm for param. modules
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Getinge Usa Sales Inc 510(k) number 2023-12-11 Class II Software design Potential cybersecurity vulnerability that could lead to a Denial of Service (DoS) attack, tampering, or remote code execution via remote login to the Flow Anesthesia System, any of which could lead to a hazardous situation. 128 (US)
Getinge Usa Sales Inc 510(k) number 2023-12-11 Class II Software design Potential cybersecurity vulnerability that could lead to a Denial of Service (DoS) attack, tampering, or remote code execution via remote login to the Flow Anesthesia System, any of which could lead to a hazardous situation. 4 (US)
Getinge Usa Sales Inc 510(k) number 2023-12-11 Class II Software design Potential cybersecurity vulnerability that could lead to a Denial of Service (DoS) attack, tampering, or remote code execution via remote login to the Flow Anesthesia System, any of which could lead to a hazardous situation. 16 (US)
Getinge Usa Sales Inc 510(k) number 2023-12-11 Class II Software design Potential cybersecurity vulnerability that could lead to a Denial of Service (DoS) attack, tampering, or remote code execution via remote login to the Flow Anesthesia System, any of which could lead to a hazardous situation. 14 (US)
Getinge Usa Sales Inc 510(k) number 2023-12-11 Class II Software design Potential cybersecurity vulnerability that could lead to a Denial of Service (DoS) attack, tampering, or remote code execution via remote login to the Flow Anesthesia System, any of which could lead to a hazardous situation. 86 (US)
Maquet Cardiovascular Us Sales, Llc 510(k) number 2015-12-10 Class I Nonconforming Material/Component Electrical issues in the control, monitoring or panel sub-systems, caused by the printed circuit boards (PCBs) that control the sub-systems. The problems manifested as multiple re-starts of the sub-systems and, in a few instances, disabling 7 units within US 2016-07-06
Maquet Cardiovascular Us Sales, Llc 510(k) number 2015-04-02 Class I Under Investigation by firm In some Flow-i Anesthesia Systems, patient cassette can get dislodged which could result in gas leakage within the system internal circuit potentially leading to a stop in ventilation. 1641 [80 units (US) 1561 units (OUS)] 2016-07-06
Maquet Cardiovascular Us Sales, Llc 510(k) number 2015-03-02 Class II Under Investigation by firm Maquet has identified that in some FLOW-i Anesthesia System Auxiliary O2 and Suction Modules, the suctioning function cannot be activated or controlled by the suction unit on/off switch leading to a decrease or loss of suctioning capability 104 units 2016-04-29

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2026-06-24 Class II Under Investigation by firm Events observed where anesthetic agent was not delivered when the vaporizer was activated. Failure to deliver the anesthetic agent may result in the patient receiving insufficient anesthesia and may lead to intraoperative awareness. 408 US; 11,342 OUS

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker