Afgo Kit (Onsite Upgrade)

Catalogue number 6686860, listed by Maquet Critical Care AB, Sweden, under Gas-Machine, Anesthesia. 4 manufacturers in China are registered for this product code.

Registry build 21.09.26
4manufacturers in China registered for this device type
1catalogue number
5510(k) clearances naming this product code
1recall

Who Else Makes It

Concentrated in Guangdong (2), Jiangsu (1), Hebei (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code BSZ
Manufacturer City Province Registered as Device types
Beijing Aeonmed Co., Ltd. Sanhe Hebei Contract manufacturer 7
Shenzhen Prunus Medical Co., Ltd. Shenzhen Guangdong Contract manufacturer 1
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57

Record

Regulatory record for Afgo kit (onsite upgrade)
Listed by Maquet Critical Care AB, Sweden
FDA product code BSZ
Device type Gas-Machine, Anesthesia
Device class Class 2
Regulation 21 CFR 868.5160
Establishment Specification developer, Complaint-file establishment, Manufacturer, Exporter
510(k) K191027
Record published 2020-05-26

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date

Catalogue Numbers

Catalogue numbers for Afgo kit (onsite upgrade)
Catalogue number Size Status
6686860 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
A9800 Anesthesia Workstation Oricare Inc. 22
Analgesia GAS Mixer, Digital MDM Delivery System Parker Hannifin Corp. 12
Aladin2 Datex-Ohmeda, Inc. 12
Penlon Penlon Ltd. 7
Analgesia GAS Mixer, MDM Delivery System Parker Hannifin Corp. 6
Codonics SLS500i Operating Software Codonics, Inc. 4
Codonics Safe Label System®(SLS) 500i Point of Care Station Codonics, Inc. 4
Spacelabs Healthcare Spacelabs Healthcare (Washington), Inc 4
Codonics Safe Label System®(SLS) 550i Point of Care Station – 144C Codonics, Inc. 3
Aestiva Datex-Ohmeda, Inc. 2
Aisys Datex-Ohmeda, Inc. 2
Infinium Medical Inc. Infinium Medical, Inc. 2

Showing 12 of 293. All products under Gas-Machine, Anesthesia

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K191027 2020-03-18
K160665 2017-03-29
K133958 2014-03-20
K112114 2012-01-13
K102182 2011-05-09

Recalls Naming This Product

11 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Afgo kit (onsite upgrade)
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Maquet Critical Care AB 510(k) number 2026-06-24 Class II Under Investigation by firm Events observed where anesthetic agent was not delivered when the vaporizer was activated. Failure to deliver the anesthetic agent may result in the patient receiving insufficient anesthesia and may lead to intraoperative awareness. 408 US; 11,342 OUS
Getinge Usa Sales Inc 510(k) number 2025-01-15 Class I Device Design Sevoflurane used with the vaporizer may degrade to hydrogen fluoride, which could present a risk to patients or health care providers through inhalation and/or skin exposure. Potential harms include irritation of respiratory tract, which in 6 units
Getinge Usa Sales Inc 510(k) number 2024-05-01 Class I Under Investigation by firm Sevoflurane used with the vaporizer may degrade to hydrogen fluoride, which could present a risk to patients or health care providers through inhalation and/or skin exposure. Potential harms include irritation of respiratory tract, which i 120 units (US)
Getinge Usa Sales Inc 510(k) number 2022-12-22 Class I Software Design Change Due to a software bug, under certain conditions, pressure cannot be built up resulting in no ventilation. If gas delivery is stopped, a sustained decrease in delivered O2 concentration may lead to hypoventilation and hypoxia. 8,016 Total (7,766 OUS; 250 US)
Getinge Usa Sales Inc 510(k) number 2022-12-22 Class I Software Design Change Due to a software bug, under certain conditions, pressure cannot be built up resulting in no ventilation. If gas delivery is stopped, a sustained decrease in delivered O2 concentration may lead to hypoventilation and hypoxia. 8.016 Total (7.766 OUS; 250 US)
Getinge Usa Sales Inc 510(k) number 2022-12-22 Class I Software Design Change Due to a software bug, under certain conditions, pressure cannot be built up resulting in no ventilation. If gas delivery is stopped, a sustained decrease in delivered O2 concentration may lead to hypoventilation and hypoxia. 8.016 Total (7.766 OUS; 250 US)
Getinge Usa Sales Inc 510(k) number 2022-11-07 Class II Component design/selection The power backup battery, under certain conditions, may exhibit reduced battery run-time while in use, and there is a potential that the battery may fail to provide the expected run time in the event of a mains power failure. This could req 65 US
Getinge Usa Sales Inc 510(k) number 2022-05-02 Class I Component design/selection Potential for crack to form on the on/off switch of the suction unit, which may result in an unreasonable risk of harm to the patient. In the worst case, the switch can break, preventing the suction unit from being activated. 17 units US 2024-08-06
Getinge Usa Sales Inc 510(k) number 2022-05-02 Class I Component design/selection Potential for crack to form on the on/off switch of the suction unit, which may result in an unreasonable risk of harm to the patient. In the worst case, the switch can break, preventing the suction unit from being activated. 47 units US 2024-08-06
Getinge Usa Sales Inc 510(k) number 2021-12-09 Class I Under Investigation by firm A potential chemical degradation of Sevoflurane by Lewis acids (metal oxides and metal halides) has been discovered that may result in inhalation and/or skin exposure of hydrogen fluoride. 50 US; 898 OUS
Getinge Group Logistics America, LLC 510(k) number 2021-01-29 Class II Device Design Maquet Critical Care AB received complaints where the FiCO2 value was not zero or as close to zero as expected and/or experienced System Check Out failures when docking the absorber to the Flow i Anesthesia machine. 144 units 2023-09-28

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.