Fabius MRI
Catalogue number 8607300, listed by Drägerwerk AG & Co. KGaA, Germany, under Gas-Machine, Anesthesia. 4 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Guangdong (2), Jiangsu (1), Hebei (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Beijing Aeonmed Co., Ltd. | Sanhe | Hebei | Contract manufacturer | 7 |
| Shenzhen Prunus Medical Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 1 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
Record
| Listed by | Drägerwerk AG & Co. KGaA, Germany |
|---|---|
| FDA product code | BSZ |
| Device type | Gas-Machine, Anesthesia |
| Device class | Class 2 |
| Regulation | 21 CFR 868.5160 |
| 510(k) | K072884 |
| Record published | 2015-10-24 |
| Record revised | 2018-07-06 (version 3) |
Specifications
| MRI safety | MR Safe |
|---|---|
| Label carries | manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 8607300 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| A9800 Anesthesia Workstation | Oricare Inc. | 22 |
| Analgesia GAS Mixer, Digital MDM Delivery System | Parker Hannifin Corp. | 12 |
| Aladin2 | Datex-Ohmeda, Inc. | 12 |
| Penlon | Penlon Ltd. | 7 |
| Analgesia GAS Mixer, MDM Delivery System | Parker Hannifin Corp. | 6 |
| Codonics SLS500i Operating Software | Codonics, Inc. | 4 |
| Codonics Safe Label System®(SLS) 500i Point of Care Station | Codonics, Inc. | 4 |
| Spacelabs Healthcare | Spacelabs Healthcare (Washington), Inc | 4 |
| Codonics Safe Label System®(SLS) 550i Point of Care Station – 144C | Codonics, Inc. | 3 |
| Aestiva | Datex-Ohmeda, Inc. | 2 |
| Aisys | Datex-Ohmeda, Inc. | 2 |
| Infinium Medical Inc. | Infinium Medical, Inc. | 2 |
Showing 12 of 293. All products under Gas-Machine, Anesthesia
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K252746 | 2026-05-21 |
| K230931 | 2023-07-23 |
Recalls Naming This Product
4 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Draeger, Inc. | 510(k) number | 2021-12-16 | Class II | Process control | 26 Fabius MRI Anesthesia machines were distributed with internal hoses routing Oxygen to the Oxygen Flush and Oxygen Flow Control interchanged. If the hospital O2 Central supply pressure is not stable, the O2 fresh gas flow could deviate fr | 5 | 2023-04-17 |
| Draeger, Inc. | 510(k) number | 2018-05-24 | Class II | Process change control | The Draeger anesthesia device may be able to dose 100% N2O. In the event of a fault, the S-ORC module would not prevent setting an N2O flow that would result in a hypoxic mixture from being dosed to the patient. Potential adverse outcomes i | 4 | 2020-05-12 |
| Draeger, Inc. | 510(k) number | 2018-03-01 | Class I | Process control | The automatic ventilation may fail if the position detection of the motor is disturbed. If the ventilator cover is damaged, manual ventilation may also fail. | 8 | 2019-04-16 |
| Draeger, Inc. | 510(k) number | 2015-06-22 | Class II | Labeling False and Misleading | the Fabius MRI or parts of the system were attracted by the magnetic field of the MRI. If the Fabius MRI is positioned too close to the MRI, its parts can be loosened as a result of the magnetic force of the MRI. | 373 | 2017-05-05 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.