Flow-C Anesthesia System
The Flow-c Anaesthesia System combines inhalation anaesthesia delivery with ventilatory support for patients from neonates to adults. It is part of a software-controlled, semi-closed system…
The Flow-c Anaesthesia System combines inhalation anaesthesia delivery with ventilatory support for patients from neonates to adults. It is part of a software-controlled, semi-closed system family using anaesthetic gases or vapours such as sevoflurane, desflurane, isoflurane and nitrous oxide.
A central core mixes and administers the gases, while the user interface sets the treatment parameters and displays ventilation and anaesthesia information. The system coordinates gas delivery and monitoring as part of the anaesthesia workflow.
Ventilation Information
The subject family includes displays of end-inspiratory pressure, positive end-expiratory pressure and dynamic compliance to support lung recruitment manoeuvres. These functions provide information for the operator during ventilation.
Who Else Makes It
Concentrated in Guangdong (2), Jiangsu (1), Hebei (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Beijing Aeonmed Co., Ltd. | Sanhe | Hebei | Contract manufacturer | 7 |
| Shenzhen Prunus Medical Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 1 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
Record
| Listed by | Maquet Critical Care AB, Sweden |
|---|---|
| FDA product code | BSZ |
| Device type | Gas-Machine, Anesthesia |
| Device class | Class 2 |
| Regulation | 21 CFR 868.5160 |
| Establishment | Specification developer, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K191027 |
| Record published | 2020-05-27 |
Specifications
| MRI safety | MR Unsafe |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 6887700 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| A9800 Anesthesia Workstation | Oricare Inc. | 22 |
| Analgesia GAS Mixer, Digital MDM Delivery System | Parker Hannifin Corp. | 12 |
| Aladin2 | Datex-Ohmeda, Inc. | 12 |
| Penlon | Penlon Ltd. | 7 |
| Analgesia GAS Mixer, MDM Delivery System | Parker Hannifin Corp. | 6 |
| Codonics SLS500i Operating Software | Codonics, Inc. | 4 |
| Codonics Safe Label System®(SLS) 500i Point of Care Station | Codonics, Inc. | 4 |
| Spacelabs Healthcare | Spacelabs Healthcare (Washington), Inc | 4 |
| Codonics Safe Label System®(SLS) 550i Point of Care Station – 144C | Codonics, Inc. | 3 |
| Aestiva | Datex-Ohmeda, Inc. | 2 |
| Aisys | Datex-Ohmeda, Inc. | 2 |
| Infinium Medical Inc. | Infinium Medical, Inc. | 2 |
Showing 12 of 293. All products under Gas-Machine, Anesthesia
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K191027 | 2020-03-18 |
| K160665 | 2017-03-29 |
| K133958 | 2014-03-20 |
| K112114 | 2012-01-13 |
| K102182 | 2011-05-09 |
Recalls Naming This Product
12 recalls name this product by its own identifiers, the UDI on its label or the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Maquet Critical Care AB | 510(k) number | 2026-06-24 | Class II | Under Investigation by firm | Events observed where anesthetic agent was not delivered when the vaporizer was activated. Failure to deliver the anesthetic agent may result in the patient receiving insufficient anesthesia and may lead to intraoperative awareness. | 408 US; 11,342 OUS | |
| Getinge Usa Sales Inc | 510(k) number | 2025-01-15 | Class I | Device Design | Sevoflurane used with the vaporizer may degrade to hydrogen fluoride, which could present a risk to patients or health care providers through inhalation and/or skin exposure. Potential harms include irritation of respiratory tract, which in | 6 units | |
| Getinge Usa Sales Inc | 510(k) number | 2024-05-01 | Class I | Under Investigation by firm | Sevoflurane used with the vaporizer may degrade to hydrogen fluoride, which could present a risk to patients or health care providers through inhalation and/or skin exposure. Potential harms include irritation of respiratory tract, which i | 120 units (US) | |
| Getinge Usa Sales Inc | UDI-DI | 2023-12-11 | Class II | Software design | Potential cybersecurity vulnerability that could lead to a Denial of Service (DoS) attack, tampering, or remote code execution via remote login to the Flow Anesthesia System, any of which could lead to a hazardous situation. | 14 (US) | |
| Getinge Usa Sales Inc | 510(k) number | 2022-12-22 | Class I | Software Design Change | Due to a software bug, under certain conditions, pressure cannot be built up resulting in no ventilation. If gas delivery is stopped, a sustained decrease in delivered O2 concentration may lead to hypoventilation and hypoxia. | 8,016 Total (7,766 OUS; 250 US) | |
| Getinge Usa Sales Inc | 510(k) number | 2022-12-22 | Class I | Software Design Change | Due to a software bug, under certain conditions, pressure cannot be built up resulting in no ventilation. If gas delivery is stopped, a sustained decrease in delivered O2 concentration may lead to hypoventilation and hypoxia. | 8.016 Total (7.766 OUS; 250 US) | |
| Getinge Usa Sales Inc | 510(k) number | 2022-12-22 | Class I | Software Design Change | Due to a software bug, under certain conditions, pressure cannot be built up resulting in no ventilation. If gas delivery is stopped, a sustained decrease in delivered O2 concentration may lead to hypoventilation and hypoxia. | 8.016 Total (7.766 OUS; 250 US) | |
| Getinge Usa Sales Inc | 510(k) number | 2022-11-07 | Class II | Component design/selection | The power backup battery, under certain conditions, may exhibit reduced battery run-time while in use, and there is a potential that the battery may fail to provide the expected run time in the event of a mains power failure. This could req | 65 US | |
| Getinge Usa Sales Inc | 510(k) number | 2022-05-02 | Class I | Component design/selection | Potential for crack to form on the on/off switch of the suction unit, which may result in an unreasonable risk of harm to the patient. In the worst case, the switch can break, preventing the suction unit from being activated. | 17 units US | 2024-08-06 |
| Getinge Usa Sales Inc | 510(k) number | 2022-05-02 | Class I | Component design/selection | Potential for crack to form on the on/off switch of the suction unit, which may result in an unreasonable risk of harm to the patient. In the worst case, the switch can break, preventing the suction unit from being activated. | 47 units US | 2024-08-06 |
| Getinge Usa Sales Inc | 510(k) number | 2021-12-09 | Class I | Under Investigation by firm | A potential chemical degradation of Sevoflurane by Lewis acids (metal oxides and metal halides) has been discovered that may result in inhalation and/or skin exposure of hydrogen fluoride. | 50 US; 898 OUS | |
| Getinge Group Logistics America, LLC | 510(k) number | 2021-01-29 | Class II | Device Design | Maquet Critical Care AB received complaints where the FiCO2 value was not zero or as close to zero as expected and/or experienced System Check Out failures when docking the absorber to the Flow i Anesthesia machine. | 144 units | 2023-09-28 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.