CAREvent DRA

CAREvent DRA hand held automatic resuscitator is pneumatically powered, time/volume cycled ventilatlatory resuscitator. It provides trained individuals with a safe and effective means of…

Registry build 21.09.26

CAREvent DRA hand held automatic resuscitator is pneumatically powered, time/volume cycled ventilatlatory resuscitator. It provides trained individuals with a safe and effective means of providing artificial ventilation during respiratory and cardiac arrest. The CAREvent DRA delivers automatic ventilation with controlled flow rate, airway pressure, tidal volume and frequency. Patients are protected from over inflation and potential barotraumas by an audible Pressure Relief System. In addition, CAREvent DRA allows the breathing patient to “Demand Breathe” on 100% oxygen at their own rate and volume. The 01CV3400 is a kit which consists of a CAREvent DRA resuscitator, a pressure regulator, a universal resuscitation facemask, an oxygen mask with oxygen tubing, a oxygen supply hose and a carrying case.

4manufacturers in China registered for this device type
2catalogue numbers in this listing
5510(k) clearances naming this product code
3recalls on this code

Who Else Makes It

Concentrated in Guangdong (3), Fujian (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code BTL
Manufacturer City Province Registered as Device types
GaleMed (Xiamen) Co., Ltd. Xiamen Fujian Contract manufacturer 33
Sunmed AP, Ltd. Zhuhai Guangdong Contract manufacturer 18
Sunmed AP, Ltd., Warehouse NO. 2 Zhuhai Guangdong Contract manufacturer 16
Dongguan Plastiflex Hose Technology Ltd Dongguan Guangdong Contract manufacturer 3

Record

Regulatory record for CAREvent DRA
Listed by O-TWO Medical Technologies, Inc., Canada
FDA product code BTL
Device type Ventilator, Emergency, Powered (Resuscitator)
Device class Class 2
Regulation 21 CFR 868.5925
Establishment Specification developer, Repacker / relabeller, Manufacturer, Exporter
Record published 2019-05-02
Record revised 2018-03-29 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number
Storage Storage environment temperature -40 to 60 °C
Sizes Weight 0.45 kg; height 2.9 in; width 2.5 in; length 5.5 in

Catalogue Numbers

Catalogue numbers for CAREvent DRA
Catalogue number Size Status
01CV3400 In distribution
01CV3000-DRA Weight 0.45 kg In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Life Support Products Allied Medical LLC 50
Neo-Tee T-Piece Resuscitator Mercury Medical Enterprises, LLC 45
Pneupac ICU Medical, Inc 38
Allied Medical LLC Allied Medical LLC 19
Fisher & Paykel Healthcare Fisher & Paykel Healthcare, Ltd. 18
AincA Anesthesia Associates, Inc. 17
Neo-Tee T-Piece Resuscitator Circuit Mercury Medical Enterprises, LLC 12
Life Support Products (LSP) Allied Medical LLC 12
Moves Thornhill Research Inc. 11
Ventlab Ventlab, LLC 7
Resusa-Tee T-Piece Resuscitator Mercury Medical Enterprises, LLC 7
Curaplex Bound Tree Medical, LLC 5

Showing 12 of 70. All products under Ventilator, Emergency, Powered (Resuscitator)

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K141595 2015-03-16
K093862 2010-05-06
K081330 2009-03-06
K051469 2005-09-28
K051889 2005-08-30

Recalls

3 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2019-02-12 Class I Process control There is a potential for the unit to catch fire due to one of the screen retaining screws being incorrectly inserted. Due to this improper screw insertion the screw sat higher than normal allowing it to contact the underside of the main boa 119 2023-06-29
2019-02-12 Class I Process control There is a potential for the unit to catch fire due to one of the screen retaining screws being incorrectly inserted. Due to this improper screw insertion the screw sat higher than normal allowing it to contact the underside of the main boa 136 2023-06-29
2019-02-12 Class I Process control There is a potential for the unit to catch fire due to one of the screen retaining screws being incorrectly inserted. Due to this improper screw insertion the screw sat higher than normal allowing it to contact the underside of the main boa 632 2023-06-29

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer