Vortran GO2VENT

The GO2VENT provides constant fl ow, pressure cycled ventilatory support in either pressure control or pressure support modes on patients weighing 10kg and above. The device includes the…

Registry build 21.09.26

The GO2VENT provides constant fl ow, pressure cycled ventilatory support in either pressure control or pressure support modes on patients weighing 10kg and above. The device includes the pulmonary modulator (an exhalation valve that opens at PIP and closes at PEEP) and a patient connector tee to supply gas fl ow, entrain additional air, and provides a redundant pop-off valve for safety. The working mechanism of the GO2VENT consists of a moving diaphragm which adds or subtracts spring force when it is moved from a horizontal to a vertical position, the addition or subtraction of spring force will aff ect the PIP setting by 1~3 cm-H2O. The GO2VENT will function in any position as long as the fi nal adjustments are made in a secured position (strapped or taped to the patient).

4manufacturers in China registered for this device type
4catalogue numbers in this listing
6510(k) clearances naming this product code
2recalls on this code

Who Else Makes It

Concentrated in Guangdong (3), Fujian (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code BTL
Manufacturer City Province Registered as Device types
GaleMed (Xiamen) Co., Ltd. Xiamen Fujian Contract manufacturer 33
Sunmed AP, Ltd. Zhuhai Guangdong Contract manufacturer 18
Sunmed AP, Ltd., Warehouse NO. 2 Zhuhai Guangdong Contract manufacturer 16
Dongguan Plastiflex Hose Technology Ltd Dongguan Guangdong Contract manufacturer 3

Record

Regulatory record for Vortran GO2VENT
Listed by Vortran Medical Technology 1, Inc., United States
FDA product code BTL
Device type Ventilator, Emergency, Powered (Resuscitator)
Device class Class 2
Regulation 21 CFR 868.5925
Establishment Repacker / relabeller, Manufacturer
510(k) K162968
Record published 2019-05-03
Record revised 2019-03-21 (version 3)

Specifications

Specifications
MRI safety MR Conditional
Single use Yes
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number, expiry date
Packaging Pack of 10, pack of 6

Catalogue Numbers

Catalogue numbers for Vortran GO2VENT
Catalogue number Size Status
6001 In distribution
6600 In distribution
6123-16 In distribution
6123 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Life Support Products Allied Medical LLC 50
Neo-Tee T-Piece Resuscitator Mercury Medical Enterprises, LLC 45
Pneupac ICU Medical, Inc 38
Allied Medical LLC Allied Medical LLC 19
Fisher & Paykel Healthcare Fisher & Paykel Healthcare, Ltd. 18
AincA Anesthesia Associates, Inc. 17
Neo-Tee T-Piece Resuscitator Circuit Mercury Medical Enterprises, LLC 12
Life Support Products (LSP) Allied Medical LLC 12
Moves Thornhill Research Inc. 11
Ventlab Ventlab, LLC 7
Resusa-Tee T-Piece Resuscitator Mercury Medical Enterprises, LLC 7
Curaplex Bound Tree Medical, LLC 5

Showing 12 of 70. All products under Ventilator, Emergency, Powered (Resuscitator)

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K202219 2021-02-11
K162968 2017-04-10
K073261 2008-05-23
K041473 2004-07-15
K001430 2000-07-05
K973975 1998-06-12

Recalls

2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2017-04-20 Class II Process control Vortran received a customer complaint that the spin-nut-DSS connector was assembled in the reverse direction on the oxygen tubing; making the connector unable to be screwed on due to the wrong thread direction. 14 cases (10 each) 2017-10-17
2017-04-20 Class II Process control Vortran received a customer complaint that the spin-nut-DSS connector was assembled in the reverse direction on the oxygen tubing; making the connector unable to be screwed on due to the wrong thread direction. 35 cases (10 each) 2017-10-17

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker