Giraffe Stand-Alone Infant Resuscitation System

Giraffe Stand-Alone Infant Resuscitation System BAG AND Mask

Registry build 21.09.26
8manufacturers in China registered for this device type
1catalogue number
1recall

Who Else Makes It

Concentrated in Fujian (4), Zhejiang (1), Guangdong (1). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code BTM
Manufacturer City Province Registered as Device types
Flexicare Medical (Dongguan) Ltd. Dongguan Guangdong Contract manufacturer 48
GaleMed (Xiamen) Co., Ltd. Xiamen Fujian Contract manufacturer 33
Polymed (Xiamen) Plastic Industrial Co., Ltd. Xiamen Fujian Contract manufacturer 17
VR Medical Technology Co., Ltd. Kunshan Jiangsu Contract manufacturer 13
Ambu Limited Xiang Yu F.T.Z., Xiamen Fujian Contract manufacturer 11
Huzhou Junda Industry Co., Ltd. Anji Zhejiang Contract manufacturer 129
Laerdal Medical (Suzhou) Co., Ltd. 215009 Suzhou Jiangsu Province Repacker / relabeller 12
Xiamen Compower Medical Tech. Co., Ltd. Xiamen Fujian Contract manufacturer 9

Record

Regulatory record for Giraffe Stand-alone Infant Resuscitation System
Listed by Datex-Ohmeda, Inc., United States
FDA product code BTM
Device type Ventilator, Emergency, Manual (Resuscitator)
Device class Class 2
Regulation 21 CFR 868.5915
Establishment Specification developer, Manufacturer, Exporter
510(k) K070247
Record published 2015-09-23
Record revised 2025-04-03 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number
Storage Storage environment humidity 0 to 95 % RH; Storage environment atmospheric pressure 50 to 106 KiloPascal; Storage environment temperature -25 to 60 °C

Catalogue Numbers

Catalogue numbers for Giraffe Stand-alone Infant Resuscitation System
Catalogue number Size Status
Bag and Mask In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Ventlab Ventlab, LLC 405
CPR-2 Bag Mercury Medical Enterprises, LLC 231
CPR Bag Mercury Medical Enterprises, LLC 187
Vital Signs™ Airlife, Inc. 102
Medline Medline Industries, Inc. 78
Spur® II Pediatric ResuscitatorSingle Patient Use Resuscitator Ambu A/S 74
Spur® II Adult ResuscitatorSingle Patient Use Resuscitator Ambu A/S 66
Hudson RCI Teleflex Medical LLC 56
Medline Industries, Inc. Medline Industries, Inc. 53
Portex ICU Medical, Inc 45
Spur® II Infant ResuscitatorSingle Patient Use Resuscitator Ambu A/S 45
Curaplex® Bound Tree Medical, LLC 38

Showing 12 of 342. All products under Ventilator, Emergency, Manual (Resuscitator)

Recalls Naming This Product

5 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Giraffe Stand-alone Infant Resuscitation System
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Datex-Ohmeda, Inc. 510(k) number 2026-05-08 Class I Process control Blender knob shaft can loosen, which can affect the delivered oxygen concentration. The system can deliver an oxygen concentration that does not match the intended concentration set by the user, potentially resulting in hypoxia or hyperoxia 550 (367 US; 183 OUS)
GE Healthcare GmbH 510(k) number 2013-12-12 Class II Process control Medical device adjustment knob may be loose and affect the accuracy of blended Air/Oxygen gas mixture to patients. 15 units 2015-06-01
GE Healthcare GmbH 510(k) number 2013-12-12 Class II Process control Medical device adjustment knob may be loose and affect the accuracy of blended Air/Oxygen gas mixture to patients. 48 units 2015-06-01
GE Medical Systems, LLC 510(k) number 2013-10-01 Class I Component design/selection Oxygen and air wall inlet fittings on the back panel of the resuscitation systems were reversed during assembly. 12, 373 units total, 8,807 = US, 3,394 = OUS, 172 = unknown 2016-07-22
GE Medical Systems, LLC 510(k) number 2012-10-15 Class I Employee error Oxygen and air wall inlet fittings on the back panel of the resuscitation systems were reversed during assembly. 276 units total, 109 of those nationwide. 2017-01-18

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer