Key Filler Bottle Adaptor MRI

Key Filler Bottle Adaptor for use with Isoflurane, Halothane & Sevoflurane in an MRI Environment

Registry build 21.09.26
1manufacturer
1catalogue number
9510(k) clearances naming this product code
1recall

Who Else Makes It

Registered in Guangdong.

Chinese manufacturers registered for FDA product code CAD
Manufacturer City Province Registered as Device types
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61

Record

Regulatory record for Key Filler Bottle Adaptor MRI
Listed by Penlon Ltd., United Kingdom
FDA product code CAD
Device type Vaporizer, Anesthesia, Non-Heated
Device class Class 2
Regulation 21 CFR 868.5880
Establishment Manufacturer
510(k) K053564
Record published 2017-08-01
Record revised 2018-07-06 (version 3)

Specifications

Specifications
MRI safety MR Conditional
Latex Labelled latex-free
Label carries lot or batch number, manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for Key Filler Bottle Adaptor MRI
Catalogue number Size Status
Key Filler Bottle Adaptor MRI In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Spacelabs Healthcare Spacelabs Healthcare (Washington), Inc 107
Penlon Penlon Ltd. 11
TEC 7 Datex-Ohmeda, Inc. 10
Antispil Southmedic, Inc. 5
Vapofil™ Southmedic, Inc. 5
TEC Datex-Ohmeda, Inc. 4
TEC 6 Plus Datex-Ohmeda, Inc. 3
AincA® Anesthesia Associates, Inc. 1
Flexible arm assembly FRU Shenzhen Mindray BIO-Medical Electronics Co., Ltd. 1
V80 Anesthetic Vaporizer Shenzhen Mindray BIO-Medical Electronics Co., Ltd. 1
Sevoflurane Key Filler Vaporizer(FDA) Shenzhen Mindray BIO-Medical Electronics Co., Ltd. 1
Vapor 3000 Drägerwerk AG & Co. KGaA 1

Showing 12 of 20. All products under Vaporizer, Anesthesia, Non-Heated

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K060331 2006-05-10
K053564 2006-03-03
K041076 2004-08-09
K002343 2001-06-08
K961468 1996-07-16
K960944 1996-04-02
K942545 1995-02-03
K936046 1994-11-04
K844007 1985-03-12

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2013-05-14 Class II Nonconforming Material/Component It has come to Penlon Ltd’s attention of an instance where the installation and pre-use checks listed in the User Manual may not have been followed prior to the clinical use of the vaporizer. Penlon Ltd has updated the Installation and dai 9208 (of which 576 were within the US) 2014-05-12

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer