Drawer for Low Mobile Carts
Catalogue number 6890365, listed by Maquet Critical Care AB, Sweden, under Ventilator, Continuous, Facility Use. 8 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Guangdong (4), Jiangsu (2), Fujian (1). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| GaleMed (Xiamen) Co., Ltd. | Xiamen | Fujian | Contract manufacturer | 33 |
| Vincent Medical (Dong Guan) Manufacturing Co., Ltd. | Dong Guan | Guangdong | Contract manufacturer | 29 |
| Sanmina | Kunshan | Jiangsu | Contract manufacturer | 15 |
| Mehow Innovative (Huizhou) Ltd. | Huizhou | Guangdong | Contract manufacturer | 11 |
| Respironics Medical Products (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 8 |
| Beijing Aeonmed Co., Ltd. | Sanhe | Hebei | Contract manufacturer | 7 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
Record
| Listed by | Maquet Critical Care AB, Sweden |
|---|---|
| FDA product code | CBK |
| Device type | Ventilator, Continuous, Facility Use |
| Device class | Class 2 |
| Regulation | 21 CFR 868.5895 |
| Establishment | Specification developer, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K201874 |
| Record published | 2023-12-10 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Label carries | manufacturing date |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 6890365 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Puritan Bennett | Covidien LP | 285 |
| Newport | Newport Medical Instruments, Inc. | 103 |
| LTV | Vyaire Medical, Inc. | 92 |
| Ventilator, Continuous, Facility Use | Hans Rudolph, Inc. | 66 |
| Infant Flow SiPAP | Carefusion | 62 |
| Avea | Carefusion | 57 |
| Ventoux | Flight Medical Innovations Ltd. | 48 |
| Trilogy | Respironics Inc. | 42 |
| Avea™ | Vyaire Medical, Inc. | 39 |
| Patient Circuits | Zoll Medical Corporation | 38 |
| Performatrak | Respironics Inc. | 35 |
| Bio-Med Devices, Inc. | BIO-MED Devices, Inc. | 34 |
Showing 12 of 419. All products under Ventilator, Continuous, Facility Use
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K201874 | 2021-04-20 |
| K180098 | 2019-03-19 |
| K151814 | 2015-12-21 |
| K123149 | 2014-06-20 |
| K073179 | 2008-06-09 |
| K063404 | 2007-02-15 |
| K062793 | 2007-02-07 |
| K041223 | 2004-07-29 |
| K040221 | 2004-02-20 |
Recalls Naming This Product
5 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Maquet Critical Care AB | 510(k) number | 2026-06-30 | Class II | Under Investigation by firm | Maquet Critical Care AB, a subsidiary of Getinge, is voluntarily recalling Y sensor module, part of the SERVO-U/-N ventilator system, due to missing production safety electrical testing. | 9 units |
| Maquet Critical Care AB | 510(k) number | 2025-05-30 | Class I | Under Investigation by firm | Potential for inaccurate measurement of the patient circuit compliance during the patient circuit test due to combination of incorrect pre-use leakage test and use of an incorrect active humidifier. | 874 units |
| Maquet Critical Care AB | 510(k) number | 2025-05-30 | Class I | Under Investigation by firm | Potential for inaccurate measurement of the patient circuit compliance during the patient circuit test due to combination of incorrect pre-use leakage test and use of an incorrect active humidifier. | 7,688 units |
| Maquet Critical Care AB | 510(k) number | 2025-05-30 | Class I | Under Investigation by firm | Potential for inaccurate measurement of the patient circuit compliance during the patient circuit test due to combination of incorrect pre-use leakage test and use of an incorrect active humidifier. | 129 units |
| Getinge Usa Sales Inc | 510(k) number | 2022-07-20 | Class I | Software in the Use Environment | Ventilators may generate a combination of alarms which may result in loss of communication, technical alarms being triggered, and loss of ventilation. If the device stops ventilating due to this issue, it may lead to hypoventilation and con | 37000 (11089 US) |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.