HAMILTON-C2

2 catalogue numbers from 160001, listed by Hamilton Medical AG, Switzerland, under Ventilator, Continuous, Facility Use. 8 manufacturers in China are registered for this product code.

Registry build 21.09.26
8manufacturers in China registered for this device type
2catalogue numbers in this listing
35510(k) clearances naming this product code
31recalls on this code

Who Else Makes It

Concentrated in Guangdong (4), Jiangsu (2), Fujian (1). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code CBK
Manufacturer City Province Registered as Device types
GaleMed (Xiamen) Co., Ltd. Xiamen Fujian Contract manufacturer 33
Vincent Medical (Dong Guan) Manufacturing Co., Ltd. Dong Guan Guangdong Contract manufacturer 29
Sanmina Kunshan Jiangsu Contract manufacturer 15
Mehow Innovative (Huizhou) Ltd. Huizhou Guangdong Contract manufacturer 11
Respironics Medical Products (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 8
Beijing Aeonmed Co., Ltd. Sanhe Hebei Contract manufacturer 7
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57

Record

Regulatory record for HAMILTON-C2
Listed by Hamilton Medical AG, Switzerland
FDA product code CBK
Device type Ventilator, Continuous, Facility Use
Device class Class 2
Regulation 21 CFR 868.5895
Establishment Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer, Exporter
Record published 2015-10-21
Record revised 2022-01-27 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number
Distribution end date 2024-08-20

Catalogue Numbers

Catalogue numbers for HAMILTON-C2
Catalogue number Size Status
160001 Withdrawn
160002 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Puritan Bennett Covidien LP 285
Newport Newport Medical Instruments, Inc. 103
LTV Vyaire Medical, Inc. 92
Ventilator, Continuous, Facility Use Hans Rudolph, Inc. 66
Infant Flow SiPAP Carefusion 62
Avea Carefusion 57
Ventoux Flight Medical Innovations Ltd. 48
Trilogy Respironics Inc. 42
Avea™ Vyaire Medical, Inc. 39
Patient Circuits Zoll Medical Corporation 38
Performatrak Respironics Inc. 35
Bio-Med Devices, Inc. BIO-MED Devices, Inc. 34

Showing 12 of 419. All products under Ventilator, Continuous, Facility Use

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K201306 2021-02-05
K201658 2020-12-11
K193228 2020-05-04
K181216 2019-08-02
K161450 2017-04-27
K153046 2016-09-06
K140939 2015-09-02
K122438 2013-11-20
K131774 2013-10-09
K123637 2012-12-21
K121225 2012-11-16
K120574 2012-05-30
K120670 2012-04-03
K112006 2012-02-09
K103803 2011-11-23
K102775 2011-01-21
K092148 2010-03-04
K090468 2009-06-15
K081521 2008-09-25
K080181 2008-06-24
K070513 2007-11-26
K071194 2007-10-18
K061090 2006-07-17
K052863 2006-01-06
K040574 2004-10-27
K022679 2003-10-22
K001686 2000-06-23
K982910 1999-09-14
K901448 1991-12-20
K900465 1990-06-18
K894426 1989-09-26
K894316 1989-09-22
K881482 1988-06-16
K871792 1988-04-21
K861432 1986-05-06

Recalls Naming This Product

1 recall names this product by its own identifier, the UDI on its label.

Recalls naming the identifiers of HAMILTON-C2
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Hamilton Medical AG UDI-DI 2023-06-15 Class I Software design Due to a software anomaly after approximately 91 days of cumulative use, the ventilator may stop and enter the ambient mode without prior notice. 399 systems

Recalls

15 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2025-06-03 Class I Equipment maintenance A mechanical defect on a printed circuit board (PCB) as a result of PCB separating process. This defect might cause the ventilator to either fail at startup (no patient involvement) or during the use of the device enter ambient state, resu 1040 systems
2024-05-15 Class I Packaging change control Ventilator may enter sensor fail mode, ventilation may not re-initiate, after patient is reconnected, which may cause hypoxia, if this sequence occurs: 1)User presses O2 enrichment, 2)User disconnects endotracheal tube for open suctioning, 68
2023-07-26 Class I Nonconforming Material/Component Degrading capacitors on the control board of ventilators and spare parts may leak electrolyte onto the control board causing a short circuit on the board and/or the capacitor to lose function and lead to interruption of ventilation. 76 units
2023-07-26 Class I Nonconforming Material/Component Degrading capacitors on the control board of ventilators and spare parts may leak electrolyte onto the control board causing a short circuit on the board and/or the capacitor to lose function and lead to interruption of ventilation. 1216 units
2023-07-26 Class I Nonconforming Material/Component Degrading capacitors on the control board of ventilators and spare parts may leak electrolyte onto the control board causing a short circuit on the board and/or the capacitor to lose function and lead to interruption of ventilation. 164 units
2023-07-26 Class I Nonconforming Material/Component Degrading capacitors on the control board of ventilators and spare parts may leak electrolyte onto the control board causing a short circuit on the board and/or the capacitor to lose function and lead to interruption of ventilation. 12 units
2023-07-26 Class I Nonconforming Material/Component Degrading capacitors on the control board of ventilators and spare parts may leak electrolyte onto the control board causing a short circuit on the board and/or the capacitor to lose function and lead to interruption of ventilation. 6 units
2023-07-26 Class I Nonconforming Material/Component Degrading capacitors on the control board of ventilators and spare parts may leak electrolyte onto the control board causing a short circuit on the board and/or the capacitor to lose function and lead to interruption of ventilation. 4 shielding set
2023-06-15 Class I Software design Due to a software anomaly after approximately 91 days of cumulative use, the ventilator may stop and enter the ambient mode without prior notice. 689 systems
2023-06-15 Class I Software design Due to a software anomaly after approximately 91 days of cumulative use, the ventilator may stop and enter the ambient mode without prior notice. 701 systems
2023-06-15 Class I Software design Due to a software anomaly after approximately 91 days of cumulative use, the ventilator may stop and enter the ambient mode without prior notice. 2319 systems
2023-03-14 Class II Software design Software error causes, safety ventilation, in which ventilation continues in the “safety ventilation” mode with audible/visible alarm – patient inputs are not monitored, if the following coincide 1) A mode change to an adaptive mode (ASV, A 103
2022-09-22 Class II Under Investigation by firm Due to a malfunction related to the backlight on the ventilator screen. The screen goes black for approximately 2-3 seconds, but it brightens up again when the backlight switches on again. 8,229 total systems worldwide (U.S. 443 systems)
2022-06-27 Class I Device Design Ventilator status indicator board can become loose, which could lead to water ingress (disinfectants) that may lead to technical fault alarms. Multiple technical faults in a short time may force ventilators into Safety Ventilation (blower r 358
2019-03-25 Class I Software design New software version for affected ventilators reduces the probability of the ventilator entering an ambient state, in which the inspiratory channel and expiratory valves are opened, letting the patient breathe room air unassisted. When the 4338 units 2024-06-03
2018-03-12 Class II Other After two and a half years, the battery fuel gauge may indicate a higher battery charge than what is available. 739 units total
2018-03-12 Class II Other After two and a half years, the battery fuel gauge may indicate a higher battery charge than what is available. 739 units total
2018-03-09 Class II Nonconforming Material/Component An out of specification component on the control board may cause the ventilator to open the inspiratory channel and the expiratory valve. The ventilator will shut down and an emergency buzzer providing an acoustic alarm and the blinking ala 16 devices 2019-03-18
2018-03-09 Class II Nonconforming Material/Component An out of specification component on the control board may cause the ventilator to open the inspiratory channel and the expiratory valve. The ventilator will shut down and an emergency buzzer providing an acoustic alarm and the blinking ala 2 devices 2019-03-18
2016-09-26 Class II Device Design Oxygen tubing and the oxygen connector of the Hamilton-MR1 could potentially become loose during the preparation for ventilation. 44 units 2017-03-08
2016-03-09 Class II Software design After performing the suctioning maneuver, including disconnecting the patient, suctioning , and reconnecting the patient, the preset pattern of ventilation many not continue as expected. 1115 2017-06-29
2015-03-24 Class II Device Design Customer reports that the ventilator display can freeze. Ventilation continues but the information is no longer displayed on the screen and the user can no longer operate the device. 248 2015-12-23
2014-04-22 Class I Device Design Ventilation and alarms of a HAMILTON-G5 ventilator can be suppressed unintentionally after the activation of a suctioning maneuver by the operator; this situation can occur regardless of the selected patient group (neonatal, pediatric and a 1128 2017-08-24
2013-09-26 Class II Device Design Manufacturer defined limits for improperly functioning loudspeakers of the HAMILTON C2 alarm system were exceeded. 316 devices distributed in the US. 2018-03-29
2012-12-19 Class I Software design Analysis of a customer complaint has shown that during ventilation of small pediatric patients with high airway resistance and low lung compliance, the oxygen consumption of a Hamilton T1 ventilator with software versions 1.1.2 and lower mu 97 total ventilators; 69 of part number 161005 and 28 of par 2014-04-22
2012-02-06 Not classified Software design Hamilton-G5 ventilators with software version V2.0x may experience an unintentional change of the displayed ventilation mode under certain conditions. 456 devices in US. 2013-10-23
2011-02-16 Not classified Software design The adaptive volume/pressure regulation can be automatically and permanently reduced to PEEP + 3 mbar when a closed suctioning maneuver is performed on the patient and may be undetected by the operator. 97 units 2012-03-21
2006-05-24 Not classified Other ALARM FAILURE-Following an oxygen cell calibration, the user may inadvertently and unknowingly disable the alarm system. 2,385 for all models 2006-12-21
2006-05-24 Not classified Other ALARM FAILURE-Following an oxygen cell calibration, the user may inadvertently and unknowingly disable the alarm system. 2,385 for all models 2006-12-21
2006-05-24 Not classified Other ALARM FAILURE-Following an oxygen cell calibration, the user may inadvertently and unknowingly disable the alarm system. 2,385 for all models 2006-12-21

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer