Humidifier Holder

Sales kit containing: 1 pc Humidification holder assembly 07325710004258 1 pc Rail clamp 07325710004265

Registry build 21.09.26
8manufacturers in China registered for this device type
2catalogue numbers in this listing
9510(k) clearances naming this product code
4recalls on this code

Who Else Makes It

Concentrated in Guangdong (4), Jiangsu (2), Fujian (1). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code CBK
Manufacturer City Province Registered as Device types
GaleMed (Xiamen) Co., Ltd. Xiamen Fujian Contract manufacturer 33
Vincent Medical (Dong Guan) Manufacturing Co., Ltd. Dong Guan Guangdong Contract manufacturer 29
Sanmina Kunshan Jiangsu Contract manufacturer 15
Mehow Innovative (Huizhou) Ltd. Huizhou Guangdong Contract manufacturer 11
Respironics Medical Products (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 8
Beijing Aeonmed Co., Ltd. Sanhe Hebei Contract manufacturer 7
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57

Record

Regulatory record for Humidifier Holder
Listed by Maquet Critical Care AB, Sweden
FDA product code CBK
Device type Ventilator, Continuous, Facility Use
Device class Class 2
Regulation 21 CFR 868.5895
Establishment Specification developer, Complaint-file establishment, Manufacturer, Exporter
510(k) K151814
Record published 2015-10-22
Record revised 2021-06-09 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied as a kit Yes
Label carries lot or batch number

Catalogue Numbers

Catalogue numbers for Humidifier Holder
Catalogue number Size Status
6523935 In distribution
6693735 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Puritan Bennett Covidien LP 285
Newport Newport Medical Instruments, Inc. 103
LTV Vyaire Medical, Inc. 92
Ventilator, Continuous, Facility Use Hans Rudolph, Inc. 66
Infant Flow SiPAP Carefusion 62
Avea Carefusion 57
Ventoux Flight Medical Innovations Ltd. 48
Trilogy Respironics Inc. 42
Avea™ Vyaire Medical, Inc. 39
Patient Circuits Zoll Medical Corporation 38
Performatrak Respironics Inc. 35
Bio-Med Devices, Inc. BIO-MED Devices, Inc. 34

Showing 12 of 419. All products under Ventilator, Continuous, Facility Use

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K201874 2021-04-20
K180098 2019-03-19
K151814 2015-12-21
K123149 2014-06-20
K073179 2008-06-09
K063404 2007-02-15
K062793 2007-02-07
K041223 2004-07-29
K040221 2004-02-20

Recalls Naming This Product

5 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Humidifier Holder
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Maquet Critical Care AB 510(k) number 2026-06-30 Class II Under Investigation by firm Maquet Critical Care AB, a subsidiary of Getinge, is voluntarily recalling Y sensor module, part of the SERVO-U/-N ventilator system, due to missing production safety electrical testing. 9 units
Maquet Critical Care AB 510(k) number 2025-05-30 Class I Under Investigation by firm Potential for inaccurate measurement of the patient circuit compliance during the patient circuit test due to combination of incorrect pre-use leakage test and use of an incorrect active humidifier. 874 units
Maquet Critical Care AB 510(k) number 2025-05-30 Class I Under Investigation by firm Potential for inaccurate measurement of the patient circuit compliance during the patient circuit test due to combination of incorrect pre-use leakage test and use of an incorrect active humidifier. 7,688 units
Maquet Critical Care AB 510(k) number 2025-05-30 Class I Under Investigation by firm Potential for inaccurate measurement of the patient circuit compliance during the patient circuit test due to combination of incorrect pre-use leakage test and use of an incorrect active humidifier. 129 units
Getinge Usa Sales Inc 510(k) number 2022-07-20 Class I Software in the Use Environment Ventilators may generate a combination of alarms which may result in loss of communication, technical alarms being triggered, and loss of ventilation. If the device stops ventilating due to this issue, it may lead to hypoventilation and con 37000 (11089 US)

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer