Iflow

2 catalogue numbers from 301.328.020, listed by Vyaire Medical, Inc., United States, under Ventilator, Continuous, Facility Use. 8 manufacturers in China are registered for this product code.

Registry build 21.09.26
8manufacturers in China registered for this device type
2catalogue numbers in this listing
1510(k) clearance
4recalls on this code

Who Else Makes It

Concentrated in Guangdong (4), Jiangsu (2), Fujian (1). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code CBK
Manufacturer City Province Registered as Device types
GaleMed (Xiamen) Co., Ltd. Xiamen Fujian Contract manufacturer 33
Vincent Medical (Dong Guan) Manufacturing Co., Ltd. Dong Guan Guangdong Contract manufacturer 29
Sanmina Kunshan Jiangsu Contract manufacturer 15
Mehow Innovative (Huizhou) Ltd. Huizhou Guangdong Contract manufacturer 11
Respironics Medical Products (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 8
Beijing Aeonmed Co., Ltd. Sanhe Hebei Contract manufacturer 7
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57

Record

Regulatory record for iFlow
Listed by Vyaire Medical, Inc., United States
FDA product code CBK
Device type Ventilator, Continuous, Facility Use
Device class Class 2
Regulation 21 CFR 868.5895
510(k) K183364
Record published 2024-11-05
Record revised 2024-11-26 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number, expiry date, manufacturing date
Storage Storage environment humidity 10 to 90 % RH; Storage environment temperature -4 to 122 °F; Special storage condition: Keep Dry; Special storage condition: Keey away from Sunlight
Packaging Case of 10

Catalogue Numbers

Catalogue numbers for iFlow
Catalogue number Size Status
301.328.020 In distribution
301.470.020 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Puritan Bennett Covidien LP 285
Newport Newport Medical Instruments, Inc. 103
LTV Vyaire Medical, Inc. 92
Ventilator, Continuous, Facility Use Hans Rudolph, Inc. 66
Infant Flow SiPAP Carefusion 62
Avea Carefusion 57
Ventoux Flight Medical Innovations Ltd. 48
Trilogy Respironics Inc. 42
Avea™ Vyaire Medical, Inc. 39
Patient Circuits Zoll Medical Corporation 38
Performatrak Respironics Inc. 35
Bio-Med Devices, Inc. BIO-MED Devices, Inc. 34

Showing 12 of 419. All products under Ventilator, Continuous, Facility Use

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K201082 2021-11-10

Recalls Naming This Product

3 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of iFlow
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Vyaire Medical, Inc. 510(k) number 2023-05-05 Class II Nonconforming Material/Component Vyaire Medical identified two patient safety risks during the use of the bellavista 1000 and bellavista 1000e:
1. Under certain conditions of use, the touchscreen may become unresponsive and the device application stops responding (APP Hang
910 units
Vyaire Medical, Inc. 510(k) number 2023-05-05 Class II Nonconforming Material/Component Vyaire Medical identified two patient safety risks during the use of the bellavista 1000 and bellavista 1000e:
1. Under certain conditions of use, the touchscreen may become unresponsive and the device application stops responding (APP Hang
392 units
Vyaire Medical, Inc. 510(k) number 2021-12-20 Class I Software change control Potential cessation in ventilation can occur under specific conditions. 4189 units 2024-08-28

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2019-11-25 Class II Software design The G6 bellavista 1000 US ventilators may experience intermittent failures: Lack of acoustic high priority alarm, presence of a ‘no alarm’ condition, or presence of non-responsive touch screen. 116 2023-08-08

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer