Neonatal Flow Sensor Insert

Catalogue number 8410179, listed by Drägerwerk AG & Co. KGaA, Germany, under Ventilator, Continuous, Facility Use. 8 manufacturers in China are registered for this product code.

Registry build 21.09.26
8manufacturers in China registered for this device type
1catalogue number

Who Else Makes It

Concentrated in Guangdong (4), Jiangsu (2), Fujian (1). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code CBK
Manufacturer City Province Registered as Device types
GaleMed (Xiamen) Co., Ltd. Xiamen Fujian Contract manufacturer 33
Vincent Medical (Dong Guan) Manufacturing Co., Ltd. Dong Guan Guangdong Contract manufacturer 29
Sanmina Kunshan Jiangsu Contract manufacturer 15
Mehow Innovative (Huizhou) Ltd. Huizhou Guangdong Contract manufacturer 11
Respironics Medical Products (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 8
Beijing Aeonmed Co., Ltd. Sanhe Hebei Contract manufacturer 7
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57

Record

Regulatory record for Neonatal flow sensor insert
Listed by Drägerwerk AG & Co. KGaA, Germany
FDA product code CBK
Device type Ventilator, Continuous, Facility Use
Device class Class 2
Regulation 21 CFR 868.5895
510(k) K974176
Record published 2022-04-08
Record revised 2023-03-27 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Label carries lot or batch number, manufacturing date

Catalogue Numbers

Catalogue numbers for Neonatal flow sensor insert
Catalogue number Size Status
8410179 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Puritan Bennett Covidien LP 285
Newport Newport Medical Instruments, Inc. 103
LTV Vyaire Medical, Inc. 92
Ventilator, Continuous, Facility Use Hans Rudolph, Inc. 66
Infant Flow SiPAP Carefusion 62
Avea Carefusion 57
Ventoux Flight Medical Innovations Ltd. 48
Trilogy Respironics Inc. 42
Avea™ Vyaire Medical, Inc. 39
Patient Circuits Zoll Medical Corporation 38
Performatrak Respironics Inc. 35
Bio-Med Devices, Inc. BIO-MED Devices, Inc. 34

Showing 12 of 419. All products under Ventilator, Continuous, Facility Use

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Neonatal flow sensor insert
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Draeger, Inc. 510(k) number 2005-12-28 Not classified Other Failure to generate an alarm when an unintended disconnection occurrs 2261 units 2007-08-07

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.