Newport Medical

Perm. 15MM/Ped Circuit W/O Water Trap and Exhalation Valve

Registry build 21.09.26
8manufacturers in China registered for this device type
6catalogue numbers in this listing
17510(k) clearances naming this product code
12recalls on this code

Who Else Makes It

Concentrated in Guangdong (4), Jiangsu (2), Fujian (1). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code CBK
Manufacturer City Province Registered as Device types
GaleMed (Xiamen) Co., Ltd. Xiamen Fujian Contract manufacturer 33
Vincent Medical (Dong Guan) Manufacturing Co., Ltd. Dong Guan Guangdong Contract manufacturer 29
Sanmina Kunshan Jiangsu Contract manufacturer 15
Mehow Innovative (Huizhou) Ltd. Huizhou Guangdong Contract manufacturer 11
Respironics Medical Products (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 8
Beijing Aeonmed Co., Ltd. Sanhe Hebei Contract manufacturer 7
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57

Record

Regulatory record for Newport Medical
Listed by Newport Medical Instruments, Inc., United States
FDA product code CBK
Device type Ventilator, Continuous, Facility Use
Device class Class 2
Regulation 21 CFR 868.5895
510(k) K111146
Record published 2018-02-01
Record revised 2022-04-25 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Over the counter Yes
Label carries lot or batch number
Storage Special storage condition: ;
Sizes Width 1.38 in; length 2 in
Distribution end date 2025-09-12

Catalogue Numbers

Catalogue numbers for Newport Medical
Catalogue number Size Per pack Status
HT600051 In distribution
KIT3420A In distribution
FLT3209P-C Width 1.38 in 5 In distribution
HT600051 In distribution
PBC460A Withdrawn
PBC335J Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Puritan Bennett Covidien LP 285
Newport Newport Medical Instruments, Inc. 103
LTV Vyaire Medical, Inc. 92
Ventilator, Continuous, Facility Use Hans Rudolph, Inc. 66
Infant Flow SiPAP Carefusion 62
Avea Carefusion 57
Ventoux Flight Medical Innovations Ltd. 48
Trilogy Respironics Inc. 42
Avea™ Vyaire Medical, Inc. 39
Patient Circuits Zoll Medical Corporation 38
Performatrak Respironics Inc. 35
Bio-Med Devices, Inc. BIO-MED Devices, Inc. 34

Showing 12 of 419. All products under Ventilator, Continuous, Facility Use

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K121891 2012-11-09
K111146 2011-12-01
K101803 2010-09-08
K090888 2009-11-18
K082724 2008-12-16
K061094 2006-07-28
K053502 2006-01-10
K030780 2004-01-23
K992133 2000-08-04
K972833 1999-09-23
K941308 1995-08-25
K941309 1995-03-06
K901785 1990-08-10
K883809 1989-06-23
K860438 1986-05-06
K844350 1984-12-27
K820746 1982-04-16

Recalls Naming This Product

4 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Newport Medical
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Covidien 510(k) number 2025-05-21 Class I Component design/selection Ventilator Printed Circuit Board Assembly may have two separate capacitors that may fail, which may result in the ventilator either shutting down during use, thus necessitating use of an alternate form of ventilation, or the shutdown alert 4842
Newport Medical Instruments, Inc. 510(k) number 2017-03-30 Class I Software in the Use Environment Medtronic is issuing a voluntary field corrective action for all its Newport” HT70 and Newport” HT70 Plus ventilators because they may shutdown spontaneously during normal operation without an accompanying alarm. 12,966 2020-07-18
Newport Medical Instruments, Inc. 510(k) number 2013-04-05 Class I Component design/selection Newport Medical Instruments is conducting a voluntary recall on certain Newport Medical Instruments HT70
and HT70 Plus ventilator Power Pac batteries due to customer reports of Newport HT70 and HT70 Plus ventilators alarming and going to in
2528 ventilators and 1864 power pac batteries 2015-03-10
Newport Medical Instruments, Inc. 510(k) number 2012-08-03 Class I Nonconforming Material/Component May emit a continuous high priority alarm and the ventilator may stop ventilating, due to a component failure on the control board. 72 2014-04-14

Recalls

The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2010-09-20 Not classified Other The recall was initiated because Newport Medical has confirmed a limited number of power cords recently received from their supplier, Glob-Tek, have a slightly oversized plug connector which prevents the
cord from locking into place. These
22 units total 2011-06-03
2010-05-14 Not classified Other The recall was initiated because Newport Medical has confirmed that the Newport HT50 hard shell Emergency Preparedness (EP) Storage Cases must be relabeled to caution users to follow current labeling guidelines for charging the battery for 1,113 EP cases 2011-06-01
2010-04-14 Not classified Other The recall was initiated due to a recent increase in complaints related to the early failure of a low pressure transducer which is on Printed Circuit Board (PCB) 2104A in the Newport e360
ventilator. Ventilators manufactured between Septemb
990 2011-08-18
2009-10-27 Not classified Mixed-up of materials/components Cregarding e360 ventilators that were shipped with a different software version from what the customers ordered. 18 2011-06-08
2009-07-22 Not classified Other The recall was initiated because Newport Medical has confirmed that the HT50 Dual Pac Ventilator is not compatiable with the external battery pack (p/n BAT3300A) supplied with the previous single battery ventilator. The Dual Pac system has 11, 333 units total 2011-06-01
2009-01-13 Not classified Other The recall was initiated because Newport Medical Instruments confirmed that the Newport HT50 ventilators that were shipped in December 2008 were without the label on the top of the ventilator that reminds users to keep HT50 ventilators plug 2011-06-01
2008-12-15 Not classified Software design In December 2008, Newport initiated a field correction to upgrade e360 ventilators with software versions 3.0 or higher to software version 3.3. As a result of this upgrade, some customers experienced unexpected device alert alarms. Newpo 4,117 units (214 Domestically; 3,903 Internationally) 2011-11-04
2007-07-31 Not classified Other Battery Life: With use over time, the internal battery begins losing its ability to hold a charge resulting in shortened ventilator operation time. Specifically, Newport has received a number of reports concerning the internal battery not l 8,160 2012-03-21
2005-10-29 Not classified Other Lack of alarm prior to shutdown. 3654 2012-08-02

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.