VentStar Oxylog 3000f (P) 190
Catalogue number 5704964, listed by Drägerwerk AG & Co. KGaA, Germany, under Ventilator, Continuous, Facility Use. 8 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Guangdong (4), Jiangsu (2), Fujian (1). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| GaleMed (Xiamen) Co., Ltd. | Xiamen | Fujian | Contract manufacturer | 33 |
| Vincent Medical (Dong Guan) Manufacturing Co., Ltd. | Dong Guan | Guangdong | Contract manufacturer | 29 |
| Sanmina | Kunshan | Jiangsu | Contract manufacturer | 15 |
| Mehow Innovative (Huizhou) Ltd. | Huizhou | Guangdong | Contract manufacturer | 11 |
| Respironics Medical Products (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 8 |
| Beijing Aeonmed Co., Ltd. | Sanhe | Hebei | Contract manufacturer | 7 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
Record
| Listed by | Drägerwerk AG & Co. KGaA, Germany |
|---|---|
| FDA product code | CBK |
| Device type | Ventilator, Continuous, Facility Use |
| Device class | Class 2 |
| Regulation | 21 CFR 868.5895 |
| 510(k) | K062267 |
| Record published | 2022-06-17 |
| Record revised | 2023-07-05 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Single use | Yes |
| Label carries | lot or batch number, expiry date, manufacturing date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 5704964 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Puritan Bennett | Covidien LP | 285 |
| Newport | Newport Medical Instruments, Inc. | 103 |
| LTV | Vyaire Medical, Inc. | 92 |
| Ventilator, Continuous, Facility Use | Hans Rudolph, Inc. | 66 |
| Infant Flow SiPAP | Carefusion | 62 |
| Avea | Carefusion | 57 |
| Ventoux | Flight Medical Innovations Ltd. | 48 |
| Trilogy | Respironics Inc. | 42 |
| Avea™ | Vyaire Medical, Inc. | 39 |
| Patient Circuits | Zoll Medical Corporation | 38 |
| Performatrak | Respironics Inc. | 35 |
| Bio-Med Devices, Inc. | BIO-MED Devices, Inc. | 34 |
Showing 12 of 419. All products under Ventilator, Continuous, Facility Use
Recalls Naming This Product
5 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Draeger, Inc. | 510(k) number | 2016-05-31 | Class I | Device Design | Isolated episodes of leakage at the check valve were found | 42,922 units worldwide (US distribution 1,530) | 2018-03-14 |
| Draeger, Inc. | 510(k) number | 2015-12-22 | Class I | Device Design | Drager became aware of situations where the error message “Poti unplugged” was generated causing acoustic and visual alarms, the breathing system releases pressure and the ventilation function stops operating. | 0 | 2017-04-05 |
| Draeger, Inc. | 510(k) number | 2015-12-22 | Class I | Device Design | Drager became aware of situations where the error message “Poti unplugged” was generated causing acoustic and visual alarms, the breathing system releases pressure and the ventilation function stops operating. | 402 units (314 – Oxylog 3000; 88 – Oxylog 3000 Plus) | 2017-04-05 |
| Draeger Medical Systems, Inc. | 510(k) number | 2010-08-19 | Not classified | Error in labeling | Patients received insufficient ventilation. The Oxylog 3000 Instructions are inadequate relating to dead space volume. | 78 potentially afftected units | 2010-11-18 |
| Draeger, Inc. | 510(k) number | 2008-10-03 | Not classified | Software design | May experience an interruption of ventilation for approximately 5 seconds | 50 units | 2009-10-16 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.