Vivo 65
Dual Limb Insert, disposable, Adult
Who Else Makes It
Concentrated in Guangdong (4), Jiangsu (2), Fujian (1). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| GaleMed (Xiamen) Co., Ltd. | Xiamen | Fujian | Contract manufacturer | 33 |
| Vincent Medical (Dong Guan) Manufacturing Co., Ltd. | Dong Guan | Guangdong | Contract manufacturer | 29 |
| Sanmina | Kunshan | Jiangsu | Contract manufacturer | 15 |
| Mehow Innovative (Huizhou) Ltd. | Huizhou | Guangdong | Contract manufacturer | 11 |
| Respironics Medical Products (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 8 |
| Beijing Aeonmed Co., Ltd. | Sanhe | Hebei | Contract manufacturer | 7 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
Record
| Listed by | Breas Medical, Inc., United States |
|---|---|
| FDA product code | CBK |
| Device type | Ventilator, Continuous, Facility Use |
| Device class | Class 2 |
| Regulation | 21 CFR 868.5895 |
| Establishment | Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K160481 |
| Record published | 2022-06-18 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, manufacturing date |
| Packaging | Box of 10 |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| 005521 | In distribution | ||
| 005523 | In distribution | ||
| 006435 | 5 | In distribution | |
| 006342 | In distribution | ||
| 005525 | In distribution | ||
| 005432 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Puritan Bennett | Covidien LP | 285 |
| Newport | Newport Medical Instruments, Inc. | 103 |
| LTV | Vyaire Medical, Inc. | 92 |
| Ventilator, Continuous, Facility Use | Hans Rudolph, Inc. | 66 |
| Infant Flow SiPAP | Carefusion | 62 |
| Avea | Carefusion | 57 |
| Ventoux | Flight Medical Innovations Ltd. | 48 |
| Trilogy | Respironics Inc. | 42 |
| Avea™ | Vyaire Medical, Inc. | 39 |
| Patient Circuits | Zoll Medical Corporation | 38 |
| Performatrak | Respironics Inc. | 35 |
| Bio-Med Devices, Inc. | BIO-MED Devices, Inc. | 34 |
Showing 12 of 419. All products under Ventilator, Continuous, Facility Use
Recalls Naming This Product
2 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Breas Medical, Inc. | 510(k) number | 2020-01-28 | Class II | Device Design | The outlet hole of the exhalation valve control pressure tube on the ventilator may become obstructed by the protective cover. | 629 | 2020-09-15 |
| Breas Medical, Inc. | 510(k) number | 2018-05-08 | Class III | Employee error | Some Vivo 65 devices have an unreleased version of the Firmware upgrade tool. | 45 | 2020-05-04 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2022-03-21 | Class II | Process control | Ventilator mounting brackets for the Vivo 50/60/65 and Vivo 45LS ventilator models can become detached from the Breas Ventilator Trolley, this may cause the ventilator to fall from the trolley and cause injury to a person who is in the imme | 707 units | 2024-12-13 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.