V30
V30, Auto, Ventilator International
Who Else Makes It
Concentrated in Guangdong (4), Beijing (1), Tianjin (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Modern Medical Equipment Manufacturing Ltd. | Heng Li, Dongguan | Guangdong | Contract manufacturer | 26 |
| Respironics Medical Products (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 8 |
| BMC (Tianjin) Medical Co., Ltd. | Wuqing District | Tianjin | Contract manufacturer | 3 |
| Huizhou RSP Technology Co., Ltd. | Huizhou | Guangdong | Contract manufacturer | 3 |
| Modern Medical Equipment Manufacturing (Qing Yuan) Ltd | Qing Yuan | Guangdong | Contract manufacturer | 26 |
| BMC Medical Co., Ltd. | Fengtai District | Beijing | Specification developer | 3 |
Record
| Listed by | Respironics Inc., United States |
|---|---|
| FDA product code | MNS |
| Device type | Ventilator, Continuous, Non-Life-Supporting |
| Device class | Class 2 |
| Regulation | 21 CFR 868.5895 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K113053 |
| Record published | 2019-06-05 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | manufacturing date, serial number |
| Storage | Storage environment humidity 15 to 95 % RH; Storage environment temperature -20 to 60 °C; Storage environment temperature -4 to 140 °F |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 1140766 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| DreamStation | Respironics Inc. | 144 |
| AF531 | Respironics Inc. | 53 |
| BiPAP autoSV Advanced System One 60 Series | Respironics Inc. | 44 |
| BiPAP Avaps | Respironics Inc. | 35 |
| DreamStation BiPAP Avaps | Respironics Inc. | 30 |
| DreamMapper | Respironics Inc. | 27 |
| BiPAP A30 | Respironics Inc. | 25 |
| BiPAP S/T C-Series | Respironics Inc. | 19 |
| OmniLab Advanced Plus | Respironics Inc. | 19 |
| EncoreAnywhere | Respironics Inc. | 17 |
| DeVilbiss | DeVilbiss Healthcare LLC. | 15 |
| Ventilator, Continuous, Non-Life-Supporting | Salter Labs | 12 |
Showing 12 of 73. All products under Ventilator, Continuous, Non-Life-Supporting
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K113053 | 2012-02-01 |
| K102465 | 2011-03-24 |
| K101130 | 2010-09-02 |
| K092818 | 2010-01-22 |
| K092043 | 2009-08-05 |
| K063540 | 2007-02-22 |
| K063533 | 2007-02-20 |
| K031656 | 2003-07-30 |
| K020777 | 2002-03-20 |
| K012323 | 2001-12-20 |
| K992530 | 2000-03-20 |
| K984407 | 1999-05-19 |
Recalls Naming This Product
5 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Respironics Inc. | 510(k) number | 2025-05-09 | Class I | Device Design | This device does not indicate for use in patients with respiratory failure. | 3 units in US 22,416 units and 49 units OUS |
| Respironics Inc. | 510(k) number | 2022-08-26 | Class I | Process control | Motor assemblies manufactured with nonconforming plastic that contributes to off-gassing of VOCs. | 146 units ***updated January 2024*** 30 additional units |
| Respironics Inc. | 510(k) number | 2021-06-14 | Class I | Device Design | The polyester-based polyurethane (PE-PUR) foam may degrade into particles which may enter the devices air pathway and be ingested or inhaled by the user, and the PE-PUR foam may off-gas certain chemicals. | 8047 |
| Respironics Inc. | 510(k) number | 2021-06-14 | Class I | Device Design | The polyester-based polyurethane (PE-PUR) foam may degrade into particles which may enter the devices air pathway and be ingested or inhaled by the user, and the PE-PUR foam may off-gas certain chemicals. | 72665 |
| Respironics Inc. | 510(k) number | 2021-06-14 | Class I | Device Design | The polyester-based polyurethane (PE-PUR) foam may degrade into particles which may enter the device s the air pathway and be ingested or inhaled by the user, and the PE-PUR foam may off-gas certain chemicals. | 15,357,775 (10,307,186 in US, 5,039,748 OUS) in total |
Recalls
10 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2025-05-09 | Class I | Device Design | This device does not indicate for use in patients with respiratory failure. | 5,958 units | |
| 2024-04-01 | Class I | Device Design | Device may experience an interruption or loss of therapy in case of a Ventilator Inoperative alarm. This may lead to hypoventilation, mild to severe hypoxemia, hypercarbia, respiratory failure/insufficiency, or potentially death. | 9,388 US; 2,664 ROW | |
| 2024-03-26 | Class I | Device Design | Potential for devices to experience interruption/loss of therapy during a Ventilator Inoperative alarm. This may lead to hypoventilation, mild to severe hypoxemia, hypercarbia, respiratory failure/insufficiency, or potentially death in the | 3 US; 21,414 OUS | |
| 2024-03-26 | Class I | Device Design | Potential for devices to experience interruption/loss of therapy during a Ventilator Inoperative alarm. This may lead to hypoventilation, mild to severe hypoxemia, hypercarbia, respiratory failure/insufficiency, or potentially death in the | 5,958 US; None OUS | |
| 2022-08-26 | Class I | Process control | Motor assemblies manufactured with nonconforming plastic that contributes to off-gassing of VOCs. | 85 units | |
| 2022-08-26 | Class I | Process control | Motor assemblies manufactured with nonconforming plastic that contributes to off-gassing of VOCs. | 34 units ***updated January 2024 *** additional 3 units | |
| 2022-08-26 | Class I | Process control | Motor assemblies manufactured with nonconforming plastic that contributes to off-gassing of VOCs. | 295 units | |
| 2022-08-26 | Class I | Process control | Motor assemblies manufactured with nonconforming plastic that contributes to off-gassing of VOCs. | 1,091 units ***updated Jan 2024*** additional 323 units | |
| 2022-08-26 | Class I | Process control | Motor assemblies manufactured with nonconforming plastic that contributes to off-gassing of VOCs. | 8 units | |
| 2021-06-14 | Class I | Device Design | The polyester-based polyurethane (PE-PUR) foam may degrade into particles which may enter the device s the air pathway and be ingested or inhaled by the user, and the PE-PUR foam may off-gas certain chemicals. | 15,357,775 (10,307,186 in US, 5,039,748 OUS) in total | |
| 2021-04-06 | Class II | Nonconforming Material/Component | Certain devices were built with motor assemblies that could contain non-conforming plastic material. This could result in 1. Exposure to off-gassing of Volatile Organic Compounds not normally present creating a potential biosafety or toxico | 2 units | 2024-01-17 |
| 2021-04-06 | Class II | Nonconforming Material/Component | Certain devices were built with motor assemblies that could contain non-conforming plastic material. This could result in 1. Exposure to off-gassing of Volatile Organic Compounds not normally present creating a potential biosafety or toxico | 22 units | 2024-01-17 |
| 2008-09-22 | Not classified | Component design/selection | Power Supply failures have occurred on some ventilators. A discrepancy between the power supply strain relief clip and the power cord connector may allow unwanted movement of the cord and the unit’s power supply. A disconnection or interm | 2,270 Power Cords | 2010-07-06 |
| 2007-10-15 | Not classified | Environmental control | Foreign material: Glass fragments may present in the plastic bag material used to ship components. | 20950 units | 2009-09-01 |
| 2007-10-15 | Not classified | Environmental control | Foreign material: Glass fragments may present in the plastic bag material used to ship components. | 20950 units | 2009-09-01 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.