Oxygen Connector

LOW Pressure Oxygen Connector

Registry build 21.09.26
4manufacturers in China registered for this device type
1catalogue number
1510(k) clearance
1recall

Who Else Makes It

Concentrated in Guangdong (3), Fujian (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code MNT
Manufacturer City Province Registered as Device types
GaleMed (Xiamen) Co., Ltd. Xiamen Fujian Contract manufacturer 33
Mehow Innovative (Huizhou) Ltd. Huizhou Guangdong Contract manufacturer 11
Respironics Medical Products (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 8
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61

Record

Regulatory record for Oxygen Connector
Listed by Resmed PTY Ltd., Australia
FDA product code MNT
Device type Sv70 Ventilator
Device class Class 2
Regulation 21 CFR 868.5895
Establishment Contract manufacturer, Complaint-file establishment, Manufacturer
Record published 2016-09-13
Record revised 2021-07-23 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Label carries lot or batch number
Storage Storage environment humidity 0 to 95 % RH; Storage environment temperature -4 to 140 °F

Catalogue Numbers

Catalogue numbers for Oxygen Connector
Catalogue number Size Status
24971 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
BiPAP A40 Respironics Inc. 102
Philips Respironics California, Inc. 29
DreamMapper Respironics Inc. 27
Fisher & Paykel Healthcare Fisher & Paykel Healthcare, Ltd. 25
BiPAP Respironics Inc. 11
EncoreAnywhere Respironics Inc. 10
Care Orchestrator Respironics Inc. 8
A Series Respironics Inc. 7
Nihon Kohden Nihon Kohden Orangemed, LLC 6
Remote Alarm Resmed PTY Ltd. 5
Stellar Resmed PTY Ltd. 5
AF811 Respironics Inc. 4

Showing 12 of 53. All products under Sv70 Ventilator

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K974539 1998-08-06

Recalls

1 of these is Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2019-12-12 Class I Device Design Combination of software and a component failure may cause audible alarms not to operate properly, the alarm buzzer not work, for ventilators that have a failed electronic component and, that are stored without AC power connected for more th 69

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer