Vivo 50
Continuous, Ventilator, Home Use
Who Else Makes It
Registered in Guangdong. One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Mehow Innovative (Huizhou) Ltd. | Huizhou | Guangdong | Contract manufacturer | 11 |
Record
| Listed by | Breas Medical, Inc., United States |
|---|---|
| FDA product code | NOU |
| Device type | Continuous, Ventilator, Home Use |
| Device class | Class 2 |
| Regulation | 21 CFR 868.5895 |
| Establishment | Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K123144 |
| Record published | 2022-06-18 |
| Record revised | 2023-03-01 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | lot or batch number, manufacturing date, serial number |
| Packaging | Box |
| Sizes | Length 10 to 50 m |
| Distribution end date | 2026-02-28 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 007219 | In distribution | |
| 004892 | Withdrawn | |
| 004896 | Length 10 m | Withdrawn |
| 005429 | Withdrawn | |
| 004897 | Length 25 m | Withdrawn |
| 005094 | Withdrawn | |
| 004891 | Withdrawn | |
| US | Withdrawn | |
| 004893 | Withdrawn | |
| US | Withdrawn | |
| 005928 | Withdrawn | |
| 005036 | Length 10 m | Withdrawn |
| 004894 | Withdrawn | |
| 005428 | Withdrawn | |
| US | Withdrawn | |
| 005223 | Length 25 m | Withdrawn |
| 004898 | Length 50 m | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Patient Circuit | Flight Medical Innovations Ltd. | 13 |
| Astral | Resmed PTY Ltd. | 12 |
| Trilogy Evo | Respironics Inc. | 10 |
| Trilogy | Respironics Inc. | 10 |
| Care Orchestrator | Respironics Inc. | 10 |
| Trilogy 200 | Respironics Inc. | 5 |
| Continuous Ventilator | Flight Medical Innovations Ltd. | 3 |
| Trilogy 100 | Respironics Inc. | 3 |
| Vocsn Roll Stand | Ventec Life Systems, Inc. | 2 |
| Sensor | Respironics Inc. | 2 |
| Astral Double Limb Kit | Resmed PTY Ltd. | 1 |
| Trilogy EV300 | Respironics Inc. | 1 |
Showing 12 of 28. All products under Continuous, Ventilator, Home Use
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K233452 | 2025-01-13 |
| K193586 | 2021-01-27 |
| K160481 | 2016-11-09 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Breas Medical, Inc. | 510(k) number | 2014-11-07 | Class II | Device Design | Unintended treatment termination could result from a keypad malfunction in some situations. The device erroneously interprets this as a Stop Treatment Instruction. An alarm will not sound, or be registered. Accessories and monitoring equipm | 846 US | 2016-04-07 |
Recalls
1 of these is Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2024-07-25 | Class I | Under Investigation by firm | There is a potential for short term (<7 days) elevated levels of formaldehyde emitted from the device into the patient breathing airpath in specific conditions. | 8298 | |
| 2023-10-13 | Class II | Process control | Produced with unintended open slits on the side of the mouthpiece body, may result in insufficient ventilation in spontaneous breathing patients using MPV-VCV and MPV-PCV modes of ventilation | 215 units | |
| 2022-06-02 | Class II | Device Design | A forced shutdown of one of the processors did not generate a watch dog alarm, would develop into a failure AND the instructions to monitor a ventilator dependent patient are NOT followed, the health consequences could potentially be Perman | 1,113 units | |
| 2020-01-28 | Class II | Device Design | The outlet hole of the exhalation valve control pressure tube on the ventilator may become obstructed by the protective cover. | 629 | 2020-09-15 |
| 2018-05-08 | Class III | Employee error | Some Vivo 65 devices have an unreleased version of the Firmware upgrade tool. | 45 | 2020-05-04 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.