Arrow
Spring-Wire Guide .018" (0.46 mm) diameter x 17-3/4" (45 cm) wire / Proximal End: Solid Wire .018" diameter / Distal End: Coil .018" diameter x 9 cm
Who Else Makes It
Concentrated in Beijing (4), Jiangsu (3), Guangdong (2). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Mehow Innovative (Huizhou) Ltd. | Huizhou | Guangdong | Contract manufacturer | 11 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Suzhou Prosteri Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 20 |
| Sunny Medical Device (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 11 |
| Lepu Medical Technology (Beijing) Co., Ltd. | Beijing | Beijing | Manufacturer | 7 |
| Beijing Target Medical Technologies Inc. | Beijing | Beijing | Contract manufacturer | 7 |
| Suzhou Zenith Vascular Scitech Limited | Suzhou | Jiangsu | Manufacturer | 6 |
| Beijing Bywave Sensing Medical Technology Co., Ltd. | Beijing | Beijing | Manufacturer | 2 |
| Shanghai Achieva Medical Suzhou Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 2 |
| Deepintec Scientific Co., Ltd. | Beijing | Beijing | Manufacturer | 2 |
Record
| Listed by | Teleflex Medical LLC, United States |
|---|---|
| FDA product code | DQX |
| Device type | Wire, Guide, Catheter |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1330 |
| Establishment | Specification developer, Complaint-file establishment, Manufacturer |
| 510(k) | K093050 |
| Record published | 2016-09-16 |
| Record revised | 2025-06-09 (version 30) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Ethylene Oxide |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Latex | Contains natural rubber latex |
| Label carries | lot or batch number, expiry date, manufacturing date, serial number |
| Storage | Storage environment temperature 20 to 25 °C |
| Packaging | Case of 5, case of 10, box of 25, case, case of 2, case of 25 |
| Sizes | Catheter gauge 5 to 12 Fr; length 5 to 130 cm; width 11 to 24 cm |
| Distribution end date | 2025-09-24 |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| IPN030340 | In distribution | |
| IPN034253 | In distribution | |
| IPN036980 | In distribution | |
| IPN920012 | In distribution | |
| IPN030338 | In distribution | |
| IPN034236 | In distribution | |
| IPN029791 | In distribution | |
| IPN036010 | In distribution | |
| IPN033853 | In distribution | |
| IPN927215 | In distribution | |
| IPN036907 | In distribution | |
| IPN032696 | In distribution | |
| IPN030334 | In distribution | |
| IPN000003 | Catheter Gauge 6 Fr | In distribution |
| IPN033004 | In distribution | |
| IPN038960 | In distribution | |
| IPN035362 | In distribution | |
| IPN037999 | In distribution | |
| IPN036232 | In distribution | |
| IPN037027 | In distribution | |
| IPN034280 | In distribution | |
| IPN036991 | In distribution | |
| IPN037047 | In distribution | |
| IPN000002 | Length 11 cm | In distribution |
| IPN036825 | In distribution | |
| IPN037728 | In distribution | |
| IPN032649 | In distribution | |
| IPN033171 | In distribution | |
| IPN039809 | In distribution | |
| IPN035741 | In distribution | |
| IPN036998 | In distribution | |
| IPN036981 | In distribution | |
| IPN037263 | Length 20 cm | In distribution |
| IPN034261 | In distribution | |
| IPN037073 | In distribution | |
| IPN920830 | In distribution | |
| IPN032665 | In distribution | |
| IPN927216 | In distribution | |
| IPN030064 | Catheter Gauge 12 Fr | In distribution |
| IPN036991 | In distribution | |
| IPN001119 | Length 11 cm | In distribution |
| IPN034254 | In distribution | |
| IPN036980 | In distribution | |
| IPN035838 | In distribution | |
| IPN034283 | In distribution | |
| IPN033585 | In distribution | |
| IPN037073 | In distribution | |
| IPN922464 | In distribution | |
| IPN032657 | In distribution | |
| IPN037012 | In distribution | |
| IPN035365 | In distribution | |
| IPN036322 | In distribution | |
| IPN919752 | In distribution | |
| IPN036224 | In distribution | |
| IPN036223 | In distribution | |
| IPN036347 | In distribution | |
| IPN039277 | In distribution | |
| IPN921748 | In distribution | |
| IPN034248 | In distribution | |
| IPN037070 | In distribution | |
| IPN929240 | In distribution | |
| IPN055562 | In distribution | |
| IPN036230 | In distribution | |
| IPN037009 | In distribution | |
| IPN904862 | In distribution | |
| IPN029644 | In distribution | |
| IPN036497 | In distribution | |
| IPN033003 | In distribution | |
| IPN030320 | In distribution | |
| IPN928253 | In distribution | |
| IPN034375 | In distribution | |
| IPN032961 | In distribution | |
| IPN035915 | In distribution | |
| IPN928684 | In distribution | |
| IPN036881 | In distribution | |
| IPN036653 | In distribution | |
| IPN035359 | In distribution | |
| IPN036231 | In distribution | |
| IPN033567 | In distribution | |
| IPN927207 | In distribution | |
| IPN032686 | In distribution | |
| IPN037153 | In distribution | |
| IPN038297 | In distribution | |
| IPN035908 | In distribution | |
| IPN034252 | In distribution | |
| IPN930565 | In distribution | |
| IPN036662 | In distribution | |
| IPN920109 | In distribution | |
| IPN037561 | In distribution | |
| IPN037033 | In distribution | |
| IPN922859 | In distribution | |
| IPN038976 | In distribution | |
| IPN036848 | In distribution | |
| IPN038173 | In distribution | |
| IPN037160 | In distribution | |
| IPN036995 | In distribution | |
| IPN055810 | In distribution | |
| IPN000015 | Width 11 cm | In distribution |
| IPN056387 | In distribution | |
| IPN037262 | In distribution | |
| IPN038368 | In distribution | |
| IPN920120 | In distribution | |
| IPN036478 | In distribution | |
| IPN056184 | In distribution | |
| IPN920010 | In distribution | |
| IPN034265 | In distribution | |
| IPN004664 | In distribution | |
| IPN037007 | In distribution | |
| IPN034399 | In distribution | |
| IPN034204 | In distribution | |
| IPN917277 | In distribution | |
| IPN033172 | In distribution | |
| IPN920014 | In distribution | |
| IPN925075 | In distribution | |
| IPN035364 | In distribution | |
| IPN036273 | In distribution | |
| IPN036276 | In distribution | |
| IPN035746 | In distribution | |
| IPN035835 | In distribution | |
| IPN038959 | In distribution | |
| IPN920933 | In distribution | |
| IPN033569 | In distribution | |
| IPN056573 | In distribution | |
| IPN034279 | In distribution | |
| IPN033843 | In distribution | |
| IPN930570 | In distribution | |
| IPN920122 | In distribution | |
| IPN034336 | In distribution | |
| IPN032903 | In distribution | |
| IPN037032 | In distribution | |
| IPN922854 | In distribution | |
| IPN037263 | In distribution | |
| IPN033570 | In distribution | |
| IPN032693 | In distribution | |
| IPN033169 | In distribution | |
| IPN920108 | In distribution | |
| IPN929479 | In distribution | |
| IPN036399 | In distribution | |
| IPN036835 | In distribution | |
| IPN929501 | In distribution | |
| IPN030067 | In distribution | |
| IPN036480 | In distribution | |
| IPN919755 | In distribution | |
| IPN036371 | In distribution | |
| IPN036062 | In distribution | |
| IPN037256 | In distribution | |
| IPN035363 | In distribution | |
| IPN033227 | In distribution | |
| IPN920118 | In distribution | |
| IPN919753 | In distribution | |
| IPN920119 | In distribution | |
| IPN923183 | In distribution | |
| IPN036829 | In distribution | |
| IPN036984 | In distribution | |
| IPN034327 | In distribution | |
| IPN036200 | In distribution | |
| IPN030310 | In distribution | |
| IPN034301 | In distribution | |
| IPN056388 | In distribution | |
| IPN055557 | In distribution | |
| IPN030326 | In distribution | |
| IPN036993 | In distribution | |
| IPN034287 | In distribution | |
| IPN034284 | In distribution | |
| IPN035374 | In distribution | |
| IPN033576 | In distribution | |
| IPN033241 | In distribution | |
| IPN034340 | In distribution | |
| IPN000014 | Catheter Gauge 5 Fr | In distribution |
| IPN036199 | In distribution | |
| IPN036984 | In distribution | |
| IPN038526 | In distribution | |
| IPN928206 | In distribution | |
| IPN038106 | In distribution | |
| IPN033853 | In distribution | |
| IPN036989 | In distribution | |
| IPN920420 | In distribution | |
| IPN922856 | In distribution | |
| IPN036478 | In distribution | |
| IPN055250 | In distribution | |
| IPN033170 | In distribution | |
| IPN914903 | In distribution | |
| IPN030311 | In distribution | |
| IPN920470 | In distribution | |
| IPN033570 | In distribution | |
| IPN001132 | Catheter Gauge 5 Fr | In distribution |
| IPN923936 | In distribution | |
| IPN034359 | In distribution | |
| IPN038370 | In distribution | |
| IPN030849 | Catheter Gauge 12 Fr | In distribution |
| IPNB00019 | In distribution | |
| IPN037098 | In distribution | |
| IPN037062 | In distribution | |
| IPN922916 | In distribution | |
| IPN925074 | In distribution | |
| IPN038269 | In distribution | |
| IPN930530 | In distribution | |
| IPN036982 | In distribution | |
| IPN033174 | In distribution | |
| IPN056277 | In distribution | |
| IPN036984 | In distribution | |
| IPN035911 | In distribution | |
| IPN037108 | In distribution | |
| IPN030013 | In distribution | |
| IPN034239 | In distribution | |
| IPN035644 | In distribution | |
| IPN030016 | In distribution | |
| IPN037063 | In distribution | |
| IPN920835 | In distribution | |
| IPN034374 | In distribution | |
| IPN034391 | In distribution | |
| IPN930531 | In distribution | |
| IPN034245 | In distribution | |
| IPN037098 | In distribution | |
| IPN929230 | In distribution | |
| IPN920107 | In distribution | |
| IPN925078 | In distribution | |
| IPN922858 | In distribution | |
| IPN034269 | In distribution | |
| IPN032607 | In distribution | |
| IPN034319 | In distribution | |
| IPN925080 | In distribution | |
| IPN030722 | In distribution | |
| IPN038978 | In distribution | |
| IPN032653 | Length 20 cm | In distribution |
| IPN036999 | In distribution | |
| IPN037423 | In distribution | |
| IPN034274 | In distribution | |
| IPN904848 | In distribution | |
| IPN920876 | In distribution | |
| IPN922857 | In distribution | |
| IPN037000 | In distribution | |
| IPN034350 | In distribution | |
| IPN036226 | In distribution | |
| IPN929926 | In distribution | |
| IPN035361 | In distribution | |
| IPN917275 | In distribution | |
| IPN927425 | In distribution | |
| IPN037043 | In distribution | |
| IPN033848 | In distribution | |
| IPN037160 | In distribution | |
| IPN038611 | In distribution | |
| IPN920873 | In distribution | |
| IPN032882 | In distribution | |
| IPN037737 | In distribution | |
| IPN037023 | In distribution | |
| IPN029798 | In distribution | |
| IPN037387 | In distribution | |
| IPN925076 | In distribution | |
| IPN037132 | In distribution |
Showing 250 of 300 catalogue numbers.
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Cook | Cook Incorporated | 410 |
| Guidewire | Argon Medical Devices, Inc. | 173 |
| Medline Industries, Inc. | Medline Industries, Inc. | 151 |
| Guidewire | Galt Medical Corp. | 144 |
| Amplatz | Cook Incorporated | 128 |
| InQwire® | Merit Medical Systems, Inc. | 120 |
| Angiographic Guide Wire | Medtronic, Inc. | 94 |
| Glidewire | Terumo Corp. | 83 |
| Starter™ Guidewire | Lake Region Medical Limited | 82 |
| INT,Falcon Guide Wire | Shanghai Kindly Medical Instruments Co., Ltd. | 72 |
| GuideRight™ | St. Jude Medical | 69 |
| INT, FirstWire | Shanghai Kindly Medical Instruments Co., Ltd. | 65 |
Showing 12 of 525. All products under Wire, Guide, Catheter
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K241784 | 2024-09-18 |
Recalls Naming This Product
34 recalls name this product by its own identifiers, the UDI on its label or the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | 510(k) number | 2026-04-21 | Class I | Nonconforming Material/Component | Lidocaine, Bupivacaine, and 0.9% sodium chloride, the subject of a supplier recall, were included into kits and sets. The supplier was found to have quality issues and limited reports of drug ineffectiveness, and if sterility of a water-bas | 310,606 | |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | UDI-DI | 2026-03-11 | Class II | Process control | Due to receiving a notice from a supplier that the liquid adhesive were incorrectly manufactured | 85 | |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | UDI-DI | 2026-03-11 | Class II | Process control | Due to receiving a notice from a supplier that the liquid adhesive was incorrectly manufactured | 675 | |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | UDI-DI | 2026-03-11 | Class II | Process control | Due to receiving a notice from a supplier that the liquid adhesive was incorrectly manufactured | 115 | |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | 510(k) number | 2024-07-26 | Class II | Nonconforming Material/Component | Reports have been received regarding open seals on the packaging. | 14,845 kits | |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | 510(k) number | 2024-02-12 | Class I | Process control | Teleflex is initiating this voluntary recall for the above-mentioned products due to reports received indicating a potentially defective component. The complaints received relate to resistance of the guidewire handle/chamber during use. Th | 1,160,470 devices | |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | 510(k) number | 2019-12-12 | Class II | Labeling Change Control | The lidstock label incorrectly displays a MR (Magnetic Resonance ) Conditional symbol (instead of a MR Unsafe symbol) in reference to a component of the kit | 80 eaches | |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | 510(k) number | 2018-04-11 | Class II | Under Investigation by firm | Product sterility may be compromised due to unsealed packaging. | 416,055 total products | 2020-05-15 |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | 510(k) number | 2018-04-11 | Class II | Under Investigation by firm | Product sterility may be compromised due to unsealed packaging. | 416,055 total products | 2020-05-15 |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | 510(k) number | 2018-04-11 | Class II | Under Investigation by firm | Product sterility may be compromised due to unsealed packaging. | 416,055 total products | 2020-05-15 |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | 510(k) number | 2018-04-11 | Class II | Under Investigation by firm | Product sterility may be compromised due to unsealed packaging. | 416,055 total products | 2020-05-15 |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | 510(k) number | 2018-04-11 | Class II | Under Investigation by firm | Product sterility may be compromised due to unsealed packaging. | 416,055 total products | 2020-05-15 |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | 510(k) number | 2018-04-11 | Class II | Under Investigation by firm | Product sterility may be compromised due to unsealed packaging. | 416,055 total products | 2020-05-15 |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | 510(k) number | 2017-12-22 | Class II | Process control | Certain lots of cardiovascular catheters may not be completely sealed and so sterility of the product cannot be guaranteed. | 2020-05-27 | |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | 510(k) number | 2017-10-26 | Class II | Nonconforming Material/Component | The povidone iodine prep pads included in certain kits and trays do not meet the requirements for a 36-month shelf life and should be labeled with a 24-month shelf life. | 930 | 2019-12-10 |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | 510(k) number | 2017-10-26 | Class II | Nonconforming Material/Component | The povidone iodine prep pads included in certain kits and trays do not meet the requirements for a 36-month shelf life and should be labeled with a 24-month shelf life. | 50,263 | 2019-12-10 |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | 510(k) number | 2017-10-26 | Class II | Nonconforming Material/Component | The povidone iodine prep pads included in certain kits and trays do not meet the requirements for a 36-month shelf life and should be labeled with a 24-month shelf life. | 24,192 | 2019-12-10 |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | 510(k) number | 2017-10-26 | Class II | Nonconforming Material/Component | The povidone iodine prep pads included in certain kits and trays do not meet the requirements for a 36-month shelf life and should be labeled with a 24-month shelf life. | 2491 | 2019-12-10 |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | 510(k) number | 2017-10-26 | Class II | Nonconforming Material/Component | The povidone iodine prep pads included in certain kits and trays do not meet the requirements for a 36-month shelf life and should be labeled with a 24-month shelf life. | 570 | 2019-12-10 |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | 510(k) number | 2017-10-26 | Class II | Nonconforming Material/Component | The povidone iodine prep pads included in certain kits and trays do not meet the requirements for a 36-month shelf life and should be labeled with a 24-month shelf life. | 6358 | 2019-12-10 |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | 510(k) number | 2017-05-09 | Class II | Packaging | Arrow International is recalling the affected product because the packaging may not be completely sealed, which may compromise sterility. | 27, 485 distributed in the U.S, 4,371 distributed Internatio | 2018-09-17 |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | 510(k) number | 2016-08-08 | Class II | Process control | Shipping carton labeling error. | 690 kits | 2017-08-22 |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | 510(k) number | 2016-08-08 | Class II | Process control | Shipping carton labeling error. | 690 kits | 2017-08-22 |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | 510(k) number | 2016-06-02 | Class II | Labeling mix-ups | Labeling error. Some shipping cartons labeled as ASK-04018-VUH contained ASK-04020-VUH kits; and some shipping cartons labeled as ASK-04020-VUH contained ASK-04018-VUH kits. | 50 units in total | 2017-08-21 |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | 510(k) number | 2016-06-02 | Class II | Labeling mix-ups | Labeling error. Some shipping cartons labeled as ASK-04018-VUH contained ASK-04020-VUH kits; and some shipping cartons labeled as ASK-04020-VUH contained ASK-04018-VUH kits. | 50 units in total | 2017-08-21 |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | 510(k) number | 2010-10-29 | Not classified | Other | Sterility may be compromised. | 361,640 | 2012-09-29 |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | 510(k) number | 2010-10-29 | Not classified | Other | Sterility may be compromised. | 800 units | 2012-09-29 |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | 510(k) number | 2010-10-29 | Not classified | Other | Sterility may be compromised. | 100 units | 2012-09-29 |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | 510(k) number | 2010-10-29 | Not classified | Other | Sterility may be compromised. | 9,230 units | 2012-09-29 |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | 510(k) number | 2010-10-29 | Not classified | Other | Sterility may be compromised. | 156,220 units | 2012-09-29 |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | 510(k) number | 2010-10-29 | Not classified | Other | Sterility may be compromised. | 8,560 units | 2012-09-29 |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | 510(k) number | 2010-10-29 | Not classified | Other | Sterility may be compromised. | 16,580 units | 2012-09-29 |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | 510(k) number | 2010-07-29 | Not classified | Mixed-up of materials/components | Incorrectly assembled 18 Ga x 2 1/2 Introducer Needle | 9 | 2012-07-05 |
| Arrow International, LLC (subsidiary of Teleflex, Incorporated) | 510(k) number | 2010-07-29 | Not classified | Mixed-up of materials/components | Incorrectly assembled 18 Ga x 2 1/2 Introducer Needle | 19 | 2012-07-05 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.