Guidewire
Guidewire 18/40/NIT/Mandrel w/Palladium Coil/Straight
Who Else Makes It
Concentrated in Beijing (4), Jiangsu (3), Guangdong (2). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Mehow Innovative (Huizhou) Ltd. | Huizhou | Guangdong | Contract manufacturer | 11 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Suzhou Prosteri Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 20 |
| Sunny Medical Device (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 11 |
| Lepu Medical Technology (Beijing) Co., Ltd. | Beijing | Beijing | Manufacturer | 7 |
| Beijing Target Medical Technologies Inc. | Beijing | Beijing | Contract manufacturer | 7 |
| Suzhou Zenith Vascular Scitech Limited | Suzhou | Jiangsu | Manufacturer | 6 |
| Beijing Bywave Sensing Medical Technology Co., Ltd. | Beijing | Beijing | Manufacturer | 2 |
| Shanghai Achieva Medical Suzhou Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 2 |
| Deepintec Scientific Co., Ltd. | Beijing | Beijing | Manufacturer | 2 |
Record
| Listed by | Argon Medical Devices, Inc., United States |
|---|---|
| FDA product code | DQX |
| Device type | Wire, Guide, Catheter |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1330 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer |
| Premarket notification | Exempt |
| Record published | 2016-09-12 |
| Record revised | 2026-05-25 (version 8) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Packaging | Box of 10, box of 50 |
| Distribution end date | 2025-01-20 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 395654 | .035″ x 50cm | In distribution |
| 395271 | .035″ x 40cm | In distribution |
| 393999 | .035″ x 180cm | In distribution |
| 395451 | .018″ x 40cm | In distribution |
| 395536 | .021″ x 25cm | In distribution |
| 395217 | .038″ x 40cm | In distribution |
| 395722 | .035″ x 200cm | In distribution |
| 395680 | .035″ x 45cm | In distribution |
| 395406 | .021″ x 260cm | In distribution |
| 395943 | .018″ x 65cm | In distribution |
| 395610 | .032″ x 40cm | In distribution |
| 395839 | .038″ x 260cm | In distribution |
| 395370 | .038″ x 260cm | In distribution |
| 395798 | .035″ x 70cm | In distribution |
| 395539 | .032″ x 65cm | In distribution |
| 388282 | .035″ x 150cm | In distribution |
| 393182 | .035″ x 150cm | In distribution |
| 395622 | .032″ x 260cm | In distribution |
| 395559 | .025″ x 150cm | In distribution |
| 390282 | .035″ x 150cm | In distribution |
| 395687 | .035″ x 150cm | In distribution |
| 395513 | .021″ x 40cm | In distribution |
| 395787 | .035″ x 150cm | In distribution |
| 395312 | .035″ x 150cm | In distribution |
| 395077 | .025″ x 260cm | In distribution |
| 395125 | .018″ x 45cm | In distribution |
| 395930E | .035″ x 150cm | In distribution |
| 393282 | .035″ x 150cm | In distribution |
| 395170 | .035″ x 180cm | In distribution |
| 395794 | .035″ x 260cm | In distribution |
| 395585 | .025″ x 260cm | In distribution |
| 395234 | .038″ x 150cm | In distribution |
| 395899 | .035″ x 65cm | In distribution |
| 395206 | .025″ x 40cm | In distribution |
| 395703 | .035″ x 200cm | In distribution |
| 395282 | .035″ x 150cm | In distribution |
| 395613 | .032″ x 125cm | In distribution |
| 395768 | .035″ x 175cm | In distribution |
| A395231 | .035″ x 150cm | In distribution |
| 395600 | .032″ x 150cm | In distribution |
| 395420 | .025″ x 150cm | In distribution |
| 395284 | .038″ x 150cm | In distribution |
| 395225 | .025″ x 150cm | In distribution |
| 388794 | .035″ x 260cm | In distribution |
| A395312 | .035″ x 150cm | In distribution |
| 395126 | .018″ x 40cm | In distribution |
| 395855 | .038″ x 50cm | In distribution |
| 395200 | .018″ x 80cm | In distribution |
| 395231 | .035″ x 150cm | In distribution |
| 395573 | .025″ x 40cm | In distribution |
| 395279 | .025″ x 125cm | In distribution |
| 395369 | .035″ x 260cm | In distribution |
| 395945 | .018″ x 100cm | In distribution |
| 395523 | .021″ x 150cm | In distribution |
| 395367 | .025″ x 260cm | In distribution |
| 395919 | .035″ x 150cm | In distribution |
| 395770 | .035″ x 50cm | In distribution |
| 395872 | .018″ x 65cm | Withdrawn |
| 395345 | .035″ x 150cm | Withdrawn |
| 395297 | .035″ x 100cm | Withdrawn |
| 388768 | .035″ x 175cm | Withdrawn |
| 388273 | .035″ x 150cm | Withdrawn |
| 395128 | .018″ x 125cm | Withdrawn |
| A395722 | .035″ x 200cm | Withdrawn |
| A395559 | .025″ x 150cm | Withdrawn |
| 395508 | .021″ x 50cm | Withdrawn |
| 393187 | .038″ x 175cm | Withdrawn |
| 390186 | .035″ x 175cm | Withdrawn |
| 395470 | .018″ x 150cm | Withdrawn |
| 390284 | .038″ x 150cm | Withdrawn |
| A395900 | .032″ x 150cm | Withdrawn |
| A395787 | .035″ x 150cm | Withdrawn |
| 395368 | .032″ x 260cm | Withdrawn |
| 395993 | .035″ x 150cm | Withdrawn |
| 395884 | .028″ x 150cm | Withdrawn |
| A395600 | .032″ x 150cm | Withdrawn |
| 395962 | .028″ x 40cm | Withdrawn |
| 395835 | .038″ x 60cm | Withdrawn |
| 395289 | .035″ x 150cm | Withdrawn |
| 395224 | .025″ x 125cm | Withdrawn |
| 395268 | .021″ x 100cm | Withdrawn |
| 395266 | .038″ x 150cm | Withdrawn |
| 395350 | .035″ x 180cm | Withdrawn |
| 395384 | .035″ x 150cm | Withdrawn |
| 395454 | .018″ x 40cm | Withdrawn |
| 395320 | .035″ x 150cm | Withdrawn |
| 395201 | .018″ x 100cm | Withdrawn |
| 395820 | .038″ x 50cm | Withdrawn |
| 395278 | .025″ x 100cm | Withdrawn |
| 395692 | .035″ x 65cm | Withdrawn |
| 395228 | .032″ x 150cm | Withdrawn |
| 395208 | .025″ x 125cm | Withdrawn |
| 395353 | .038″ x 150cm | Withdrawn |
| 395900 | .032″ x 150cm | Withdrawn |
| 395989 | .028″ x 50cm | Withdrawn |
| 395280 | .035″ x 150cm | Withdrawn |
| 395204 | .021″ x 100cm | Withdrawn |
| 395863 | .038″ x 150cm | Withdrawn |
| 395541 | .021″ x 50cm | Withdrawn |
| 395817 | .038″ x 200cm | Withdrawn |
| 395711 | .035″ x 75cm | Withdrawn |
| 395875 | .025″ x 65cm | Withdrawn |
| 395112 | .035″ x 150cm | Withdrawn |
| 395931 | .032″ x 150cm | Withdrawn |
| 388301 | .035″ x 150cm | Withdrawn |
| 395258 | .035″ x 150cm | Withdrawn |
| 395746 | .035″ x 75cm | Withdrawn |
| 395868 | .035″ x 80cm | Withdrawn |
| 395844 | .038″ x 70cm | Withdrawn |
| A395284 | .038″ x 150cm | Withdrawn |
| 395382 | .035″ x 150cm | Withdrawn |
| 395415 | .025″ x 65cm | Withdrawn |
| 395721 | .035″ x 145cm | Withdrawn |
| 395213 | .035″ x 40cm | Withdrawn |
| 395752 | .035″ x 75cm | Withdrawn |
| 395501 | .021″ x 150cm | Withdrawn |
| 393186 | .035″ x 175cm | Withdrawn |
| 393184 | .038″ x 150cm | Withdrawn |
| 395961 | .028″ x 150cm | Withdrawn |
| 395309 | .032″ x 150cm | Withdrawn |
| 395352 | .035″ x 150cm | Withdrawn |
| 395998 | .035″ x 50cm | Withdrawn |
| A395282 | .035″ x 150cm | Withdrawn |
| 395933C | .038″ x 150cm | Withdrawn |
| 395183 | .035″ x 150cm | Withdrawn |
| 395504 | .021″ x 125cm | Withdrawn |
| 395203 | .021″ x 80cm | Withdrawn |
| 395073 | .035″ x 260cm | Withdrawn |
| A395369 | .035″ x 260cm | Withdrawn |
| 395980 | .017″ x 150cm | Withdrawn |
| 395333 | .038″ x 260cm | Withdrawn |
| 388300 | .035″ x 150cm | Withdrawn |
| 395708 | .035″ x 150cm | Withdrawn |
| 395730 | .018″ x 50cm | Withdrawn |
| 395603 | .032″ x 150cm | Withdrawn |
| 395465 | .018″ x 150cm | Withdrawn |
| 395398 | .035″ x 150cm | Withdrawn |
| 395337 | .035″ x 125cm | Withdrawn |
| 395330 | .038″ x 260cm | Withdrawn |
| 395270 | .025″ x 125cm | Withdrawn |
| 395400 | .025″ x 50cm | Withdrawn |
| 395979 | .015″ x 150cm | Withdrawn |
| 390182 | .035″ x 150cm | Withdrawn |
| 395275 | .038″ x 150cm | Withdrawn |
| 395946 | .021″ x 65cm | Withdrawn |
| 395924 | .038″ x 80cm | Withdrawn |
| 395780 | .035″ x 150cm | Withdrawn |
| 395422 | .025″ x 40cm | Withdrawn |
| 395948 | .021″ x 100cm | Withdrawn |
| A395613 | .032″ x 125cm | Withdrawn |
| 395522 | .021″ x 260cm | Withdrawn |
| A395482 | .035″ x 180cm | Withdrawn |
| 395273 | .035″ x 150cm | Withdrawn |
| 395205 | .021″ x 125cm | Withdrawn |
| 395701 | .035″ x 70cm | Withdrawn |
| 388275 | .038″ x 150cm | Withdrawn |
| 395315 | .038″ x 150cm | Withdrawn |
| 395076 | .025″ x 150cm | Withdrawn |
| 395991 | .030″ x 150cm | Withdrawn |
| 395261 | .038″ x 150cm | Withdrawn |
| 395332 | .032″ x 150cm | Withdrawn |
| 395457 | .018″ x 150cm | Withdrawn |
| 395656 | .035″ x 200cm | Withdrawn |
| 395469 | .018″ x 260cm | Withdrawn |
| 395518 | .021″ x 80cm | Withdrawn |
| 395537 | .021″ x 40cm | Withdrawn |
| 395510 | .021″ x 40cm | Withdrawn |
| 395874 | .021″ x 65cm | Withdrawn |
| 395281 | .035″ x 125cm | Withdrawn |
| 395732 | .021″ x 50cm | Withdrawn |
| 388284 | .038″ x 150cm | Withdrawn |
| 395212 | .032″ x 150cm | Withdrawn |
| 395509 | .021″ x 150cm | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Arrow | Teleflex Medical LLC | 625 |
| Cook | Cook Incorporated | 410 |
| Medline Industries, Inc. | Medline Industries, Inc. | 151 |
| Guidewire | Galt Medical Corp. | 144 |
| Amplatz | Cook Incorporated | 128 |
| InQwire® | Merit Medical Systems, Inc. | 120 |
| Angiographic Guide Wire | Medtronic, Inc. | 94 |
| Glidewire | Terumo Corp. | 83 |
| Starter™ Guidewire | Lake Region Medical Limited | 82 |
| INT,Falcon Guide Wire | Shanghai Kindly Medical Instruments Co., Ltd. | 72 |
| GuideRight™ | St. Jude Medical | 69 |
| INT, FirstWire | Shanghai Kindly Medical Instruments Co., Ltd. | 65 |
Showing 12 of 525. All products under Wire, Guide, Catheter
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K160785 | 2016-12-08 |
Recalls
2 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2019-12-04 | Class I | Employee error | The stiffness of the soft end of the guidewire caused tissue perforation. | 1690 units | 2024-04-01 |
| 2019-12-04 | Class I | Employee error | The stiffness of the soft end of the guidewire caused tissue perforation. | 1190 units | 2024-04-01 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 500 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 500 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 50 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 72 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 393 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 220 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 20 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 13 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 7,885 | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 100 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 55 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 30 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 5,521 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 300 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 800 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 1,285 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 325 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 30 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 401 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 130 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 65 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 75 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 1,749 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 4 | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 700 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 1,400 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 2,600 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 3 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 25 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 45 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 750 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 1,566 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 7,160 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 18 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 427 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 100 units | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 275 | 2010-01-07 |
| 2009-02-26 | Not classified | Other | Hydrophilic guidewires have the potential to demonstrate degradation of the Pebax cladding. | 3,300 units | 2010-01-07 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.