Amplatzer™ TorqVue™
LP Delivery System
Who Else Makes It
Concentrated in Shanghai (5), Jiangsu (5), Guangdong (3). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Jabil Circuit (Shanghai) Ltd. | Shanghai | Shanghai | Contract manufacturer | 31 |
| Covidien Medical Products (Shanghai) Manufacturing LLC | Shanghai | Shanghai | Contract manufacturer | 8 |
| Sterigenics Shanghai ETO Ltd. | Shanghai | Shanghai | Contract manufacturer | 65 |
| Steris Sterilization Technologies (Suzhou) Ltd | Suzhou | Jiangsu | Contract manufacturer | 44 |
| Goals Sterilization Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 26 |
| Wuxi Goals Medical Technology Co., Ltd. | Yixing | Jiangsu | Contract manufacturer | 24 |
| Suzhou Zenith Vascular Scitech Limited | Suzhou | Jiangsu | Manufacturer | 6 |
| Haolang Technology (Foshan) Limited Corporation | Foshan | Guangdong | Contract manufacturer | 6 |
| OrbusNeich Medical (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Complaint-file establishment | 5 |
| Curatia Medical Limited | Suzhou | Jiangsu | Specification developer | 5 |
| Shanghai Wallaby Medical Technologies Co., Inc. | Shanghai | Shanghai | Contract manufacturer | 5 |
| DK Medical Technology Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 3 |
Showing 12 of 14. All 14 manufacturers in China registered for Catheter, Percutaneous
Record
| Listed by | St. Jude Medical, United States |
|---|---|
| FDA product code | DQY |
| Device type | Catheter, Percutaneous |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1250 |
| Establishment | Manufacturer, Exporter |
| Record published | 2015-03-09 |
| Record revised | 2024-02-22 (version 6) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date |
| Storage | Special storage condition: Keep dry. |
| Sizes | Catheter gauge 4 to 7 Fr; length 60 to 80 cm |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 9-TVLP4F90/060 | Catheter Gauge 4 Fr | In distribution |
| 9-TVLP5F90/060 | Catheter Gauge 5 Fr | In distribution |
| 9-TV2-06F120 | Catheter Gauge 6 Fr | In distribution |
| 9-TVLP4F90/080 | Catheter Gauge 4 Fr | In distribution |
| 9-TVLP5F90/080 | Catheter Gauge 5 Fr | In distribution |
| 9-TV2-07F120 | Catheter Gauge 7 Fr | In distribution |
| 9-TV2-05F120 | Catheter Gauge 5 Fr | In distribution |
| 9-TVLPC4F90/080 | Catheter Gauge 4 Fr | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Launcher™ | Medtronic, Inc. | 3,805 |
| Sherpa NX Balanced™ | Medtronic, Inc. | 1,523 |
| Arrow | Teleflex Medical LLC | 1,249 |
| Z2 | Medtronic, Inc. | 955 |
| Vista Brite TIP | Cordis Corp. | 789 |
| Mach1™ | Boston Scientific Corporation | 777 |
| Sherpa NX Active | Medtronic, Inc. | 571 |
| Zuma® | Medtronic, Inc. | 569 |
| Convey | Pendracare International B.V. | 532 |
| Taiga | Medtronic, Inc. | 307 |
| RunWay™ | Boston Scientific Corporation | 300 |
| ConcierGE Guiding Excellence™ | Merit Medical Systems, Inc. | 295 |
Showing 12 of 500. All products under Catheter, Percutaneous
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K142235 | 2014-12-18 |
| K142239 | 2014-12-18 |
| K131592 | 2014-01-31 |
| K131063 | 2013-08-15 |
| K130257 | 2013-03-20 |
| K130252 | 2013-03-20 |
| K082932 | 2008-12-12 |
| K073700 | 2008-10-02 |
| K063638 | 2007-05-11 |
| K061843 | 2006-08-01 |
| K061710 | 2006-07-14 |
| K053217 | 2006-03-08 |
| K053277 | 2006-02-24 |
Recalls Naming This Product
2 recalls name this product by its own identifiers, the UDI on its label.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| St. Jude Medical, Cardiology Division, Inc. | UDI-DI | 2025-03-17 | Class II | Process control | Device may have a small breach in the proximal end of the shaft under the strain relief of the delivery system. Breach is not visibly detectable and may lead to prolonged procedure, blood loss, or air ingress with potential for air embolism | 4,850 |
| St. Jude Medical, Cardiology Division, Inc. | UDI-DI | 2025-03-17 | Class II | Process control | Device may have a small breach in the proximal end of the shaft under the strain relief of the delivery system. Breach is not visibly detectable and may lead to prolonged procedure, blood loss, or air ingress with potential for air embolism | 2683 |
Recalls
1 of these is Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2013-01-18 | Class I | Device Design | The distal end of the core wire of the TorqVue FX Delivery System could potentially fracture when exposed to a combination of certain cardiac anatomies and usage conditions. | 635 | 2013-05-21 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.