Kittykat II
"Kittycat 2 Catheter is a 5F sheath and 0.014” guidewire compatible over-the-wire device with a working length of 150 cm. It consists of a catheter shaft with handle assembly at the…
“Kittycat 2 Catheter is a 5F sheath and 0.014” guidewire compatible over-the-wire device with a working length of 150 cm. It consists of a catheter shaft with handle assembly at the proximal end and an atraumatic Distal Tip. A locking Luer connecter at the proximal end provides entry to a lumen that supports and facilitates movement of a guidewire. The catheter has been irradiated for sterility and is intended for single use only.The Distal Tip houses Spiral Flutes and allows atraumatic advancement of the catheter through the vasculature. The pre-shaped Distal Tip is made of a malleable material and may be reshaped as needed by the user. The deflection of the Distal Tip is visible under fluoroscopic guidance. The handle assembly consists of a Handle Body, Rotator, and Luer. The Handle Body controls rotational orientation of the catheter, including the flexible Distal Tip. The Rotator controls the rotational movement of the Distal Tip, independent of the catheter orientation. The Luer is provided at the proximal end to facilitate fluid flush and the entry/exit of the guidewire. Kittycat 2 is intended to facilitate the intraluminal placement of conventional guidewires beyond stenotic lesions (including sub and chronic total occlusions) in the peripheral vasculature prior to further percutaneous intervention. The Kittycat 2 Catheter is contraindicated for use in the iliac, coronary, cerebral or carotid vasculature. Kittycat 2 is intended to be used to support steerable guidewires in accessing discrete regions of the peripheral vasculature. It may be used to facilitate placement and exchange of guidewires and other interventional devices. It may also be used to deliver saline or contrast.”
Who Else Makes It
Concentrated in Shanghai (5), Jiangsu (5), Guangdong (3). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Jabil Circuit (Shanghai) Ltd. | Shanghai | Shanghai | Contract manufacturer | 31 |
| Covidien Medical Products (Shanghai) Manufacturing LLC | Shanghai | Shanghai | Contract manufacturer | 8 |
| Sterigenics Shanghai ETO Ltd. | Shanghai | Shanghai | Contract manufacturer | 65 |
| Steris Sterilization Technologies (Suzhou) Ltd | Suzhou | Jiangsu | Contract manufacturer | 44 |
| Goals Sterilization Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 26 |
| Wuxi Goals Medical Technology Co., Ltd. | Yixing | Jiangsu | Contract manufacturer | 24 |
| Suzhou Zenith Vascular Scitech Limited | Suzhou | Jiangsu | Manufacturer | 6 |
| Haolang Technology (Foshan) Limited Corporation | Foshan | Guangdong | Contract manufacturer | 6 |
| OrbusNeich Medical (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Complaint-file establishment | 5 |
| Curatia Medical Limited | Suzhou | Jiangsu | Specification developer | 5 |
| Shanghai Wallaby Medical Technologies Co., Inc. | Shanghai | Shanghai | Contract manufacturer | 5 |
| DK Medical Technology Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 3 |
Showing 12 of 14. All 14 manufacturers in China registered for Catheter, Percutaneous
Record
| Listed by | Avinger, Inc., United States |
|---|---|
| FDA product code | DQY |
| Device type | Catheter, Percutaneous |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1250 |
| 510(k) | K120273 |
| Record published | 2019-03-21 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Radiation Sterilization |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| W550` | In distribution | |
| E550 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Launcher™ | Medtronic, Inc. | 3,805 |
| Sherpa NX Balanced™ | Medtronic, Inc. | 1,523 |
| Arrow | Teleflex Medical LLC | 1,249 |
| Z2 | Medtronic, Inc. | 955 |
| Vista Brite TIP | Cordis Corp. | 789 |
| Mach1™ | Boston Scientific Corporation | 777 |
| Sherpa NX Active | Medtronic, Inc. | 571 |
| Zuma® | Medtronic, Inc. | 569 |
| Convey | Pendracare International B.V. | 532 |
| Taiga | Medtronic, Inc. | 307 |
| RunWay™ | Boston Scientific Corporation | 300 |
| ConcierGE Guiding Excellence™ | Merit Medical Systems, Inc. | 295 |
Showing 12 of 500. All products under Catheter, Percutaneous
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K112579 | 2011-10-06 |
| K111704 | 2011-09-09 |
| K101647 | 2010-08-06 |
| K102022 | 2010-08-06 |
| K083313 | 2009-02-02 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.