Navicross
NAVICROSS Support Catheter
14manufacturers in China registered for this device type
16catalogue numbers in this listing
5510(k) clearances naming this product code
Who Else Makes It
Concentrated in Shanghai (5), Jiangsu (5), Guangdong (3). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Jabil Circuit (Shanghai) Ltd. | Shanghai | Shanghai | Contract manufacturer | 31 |
| Covidien Medical Products (Shanghai) Manufacturing LLC | Shanghai | Shanghai | Contract manufacturer | 8 |
| Sterigenics Shanghai ETO Ltd. | Shanghai | Shanghai | Contract manufacturer | 65 |
| Steris Sterilization Technologies (Suzhou) Ltd | Suzhou | Jiangsu | Contract manufacturer | 44 |
| Goals Sterilization Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 26 |
| Wuxi Goals Medical Technology Co., Ltd. | Yixing | Jiangsu | Contract manufacturer | 24 |
| Suzhou Zenith Vascular Scitech Limited | Suzhou | Jiangsu | Manufacturer | 6 |
| Haolang Technology (Foshan) Limited Corporation | Foshan | Guangdong | Contract manufacturer | 6 |
| OrbusNeich Medical (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Complaint-file establishment | 5 |
| Curatia Medical Limited | Suzhou | Jiangsu | Specification developer | 5 |
| Shanghai Wallaby Medical Technologies Co., Inc. | Shanghai | Shanghai | Contract manufacturer | 5 |
| DK Medical Technology Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 3 |
Showing 12 of 14. All 14 manufacturers in China registered for Catheter, Percutaneous
Record
| Listed by | Terumo Corp., Japan |
|---|---|
| FDA product code | DQY |
| Device type | Catheter, Percutaneous |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1250 |
| Establishment | Contract manufacturer, Contract steriliser, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2018-04-25 |
| Record revised | 2021-12-22 (version 6) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Storage | Special storage condition: Fragile. Keep dry. Keep away from sunlight. Stacking limit by 9. |
| Packaging | Carton of 5 |
| Sizes | Outer diameter 0.85 to 1.39 mm; length 65 to 150 cm; pressure 5171 KiloPascal |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| NC18150 | Outer Diameter 0.85 mm | In distribution |
| NC18130 | Length 135 cm | In distribution |
| NC35651 | Outer Diameter 1.39 mm | In distribution |
| NC18900 | Outer Diameter 0.85 mm | In distribution |
| NC18901 | Max Guide wire O.D. 0.018” (0.46 mm) | In distribution |
| NC18650 | Outer Diameter 0.85 mm | In distribution |
| NC35130 | Outer Diameter 1.39 mm | In distribution |
| NC18651 | Max Guide wire O.D. 0.018” (0.46 mm) | In distribution |
| NC35900 | Pressure 5171 KiloPascal | In distribution |
| NC35650 | Max Guide Wire O.D. : 0.035″ (0.89mm) | In distribution |
| NC35151 | Max Guide Wire O.D. : 0.035″ (0.89mm) | In distribution |
| NC35131 | Outer Diameter 1.39 mm | In distribution |
| NC18131 | Max Guide wire O.D. 0.018” (0.46 mm) | In distribution |
| NC35150 | Tip shape : Straight | In distribution |
| NC35901 | Length 90 cm | In distribution |
| NC18151 | Max Guide wire O.D. 0.018” (0.46 mm) | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Launcher™ | Medtronic, Inc. | 3,805 |
| Sherpa NX Balanced™ | Medtronic, Inc. | 1,523 |
| Arrow | Teleflex Medical LLC | 1,249 |
| Z2 | Medtronic, Inc. | 955 |
| Vista Brite TIP | Cordis Corp. | 789 |
| Mach1™ | Boston Scientific Corporation | 777 |
| Sherpa NX Active | Medtronic, Inc. | 571 |
| Zuma® | Medtronic, Inc. | 569 |
| Convey | Pendracare International B.V. | 532 |
| Taiga | Medtronic, Inc. | 307 |
| RunWay™ | Boston Scientific Corporation | 300 |
| ConcierGE Guiding Excellence™ | Merit Medical Systems, Inc. | 295 |
Showing 12 of 500. All products under Catheter, Percutaneous
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K231044 | 2023-07-27 |
| K173799 | 2018-03-29 |
| K111556 | 2011-07-29 |
| K110540 | 2011-05-13 |
| K981359 | 1999-01-27 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.