NHancer Rx
The FDA summary names NHancer Rx as a dual-lumen rapid-exchange catheter and identifies the listed NHancer Rx family. The catheter includes an over-the-wire lumen along its length and a…
The FDA summary names NHancer Rx as a dual-lumen rapid-exchange catheter and identifies the listed NHancer Rx family.
The catheter includes an over-the-wire lumen along its length and a rapid-exchange delivery lumen at the distal end.
Listed Item
The NHancer™Rx is a dual lumen catheter intended to use in the coronary and/or peripheral vasculature. The NHancer™Rx is a 0.014” Rapid Exchange (Rx) guide wire support catheter. The NHancer™Rx has an over the wire (OTW) lumen that runs the length of the catheter and a rapid exchange (RX) delivery lumen on the distal end. The NHancer™Rx has an effective length of 135 cm and is compatible with 0.014”/0.36mm or smaller guide wires. The NHancer™Rx has two depth markings located at 95 cm and 105 cm from the distal tip. The NHancer™Rx has a radiopaque marker identifying the distal end of the catheter and a second radiopaque marker located 8 mm from the distal tip identifies the distal end of the OTW lumen. To reduce friction in the guide catheter and vasculature, the distal 15 cm of the shaft is fitted with a hydrophilic coating. To reduce friction of the guide wire in the lumen, the entire lumens of the NHancer Rx are coated with MDX (silicone) coating. To ease catheter loading into the hemostasis device and the guiding catheter a removable stylet (9) is placed in the OTW lumen
Guidewire Compatibility
The filing gives an effective length of 135 centimeters and compatibility with 0.014-inch or smaller guidewires. It describes two radiopaque markers and a hydrophilic coating on the distal 15 centimeters of the shaft.
Who Else Makes It
Concentrated in Shanghai (5), Jiangsu (5), Guangdong (3). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Jabil Circuit (Shanghai) Ltd. | Shanghai | Shanghai | Contract manufacturer | 31 |
| Covidien Medical Products (Shanghai) Manufacturing LLC | Shanghai | Shanghai | Contract manufacturer | 8 |
| Sterigenics Shanghai ETO Ltd. | Shanghai | Shanghai | Contract manufacturer | 65 |
| Steris Sterilization Technologies (Suzhou) Ltd | Suzhou | Jiangsu | Contract manufacturer | 44 |
| Goals Sterilization Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 26 |
| Wuxi Goals Medical Technology Co., Ltd. | Yixing | Jiangsu | Contract manufacturer | 24 |
| Suzhou Zenith Vascular Scitech Limited | Suzhou | Jiangsu | Manufacturer | 6 |
| Haolang Technology (Foshan) Limited Corporation | Foshan | Guangdong | Contract manufacturer | 6 |
| OrbusNeich Medical (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Complaint-file establishment | 5 |
| Curatia Medical Limited | Suzhou | Jiangsu | Specification developer | 5 |
| Shanghai Wallaby Medical Technologies Co., Inc. | Shanghai | Shanghai | Contract manufacturer | 5 |
| DK Medical Technology Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 3 |
Showing 12 of 14. All 14 manufacturers in China registered for Catheter, Percutaneous
Record
| Listed by | Imds Operations B.V., Netherlands |
|---|---|
| FDA product code | DQY |
| Device type | Catheter, Percutaneous |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1250 |
| Establishment | Contract manufacturer, Manufacturer |
| 510(k) | K200324 |
| Record published | 2022-09-01 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| NRX1413518 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Launcher™ | Medtronic, Inc. | 3,805 |
| Sherpa NX Balanced™ | Medtronic, Inc. | 1,523 |
| Arrow | Teleflex Medical LLC | 1,249 |
| Z2 | Medtronic, Inc. | 955 |
| Vista Brite TIP | Cordis Corp. | 789 |
| Mach1™ | Boston Scientific Corporation | 777 |
| Sherpa NX Active | Medtronic, Inc. | 571 |
| Zuma® | Medtronic, Inc. | 569 |
| Convey | Pendracare International B.V. | 532 |
| Taiga | Medtronic, Inc. | 307 |
| RunWay™ | Boston Scientific Corporation | 300 |
| ConcierGE Guiding Excellence™ | Merit Medical Systems, Inc. | 295 |
Showing 12 of 500. All products under Catheter, Percutaneous
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K242337 | 2025-04-17 |
| K241611 | 2024-09-03 |
| K223728 | 2023-07-13 |
| K210431 | 2021-07-15 |
| K210110 | 2021-03-31 |
| K200324 | 2020-08-06 |
| K191229 | 2020-01-21 |
| K121077 | 2012-12-21 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.