Quick-Cross™Extreme™
Quick-Cross™Extreme™ Support Catheter
Who Else Makes It
Concentrated in Shanghai (5), Jiangsu (5), Guangdong (3). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Jabil Circuit (Shanghai) Ltd. | Shanghai | Shanghai | Contract manufacturer | 31 |
| Covidien Medical Products (Shanghai) Manufacturing LLC | Shanghai | Shanghai | Contract manufacturer | 8 |
| Sterigenics Shanghai ETO Ltd. | Shanghai | Shanghai | Contract manufacturer | 65 |
| Steris Sterilization Technologies (Suzhou) Ltd | Suzhou | Jiangsu | Contract manufacturer | 44 |
| Goals Sterilization Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 26 |
| Wuxi Goals Medical Technology Co., Ltd. | Yixing | Jiangsu | Contract manufacturer | 24 |
| Suzhou Zenith Vascular Scitech Limited | Suzhou | Jiangsu | Manufacturer | 6 |
| Haolang Technology (Foshan) Limited Corporation | Foshan | Guangdong | Contract manufacturer | 6 |
| OrbusNeich Medical (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Complaint-file establishment | 5 |
| Curatia Medical Limited | Suzhou | Jiangsu | Specification developer | 5 |
| Shanghai Wallaby Medical Technologies Co., Inc. | Shanghai | Shanghai | Contract manufacturer | 5 |
| DK Medical Technology Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 3 |
Showing 12 of 14. All 14 manufacturers in China registered for Catheter, Percutaneous
Record
| Listed by | Spectranetics Corp., United States |
|---|---|
| FDA product code | DQY |
| Device type | Catheter, Percutaneous |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1250 |
| Establishment | Specification developer, Complaint-file establishment, Manufacturer |
| 510(k) | K092396 |
| Record published | 2015-02-06 |
| Record revised | 2021-12-22 (version 9) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Ethylene Oxide |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Storage | Special storage condition: Keep Dry; Storage environment temperature up to 131 °F |
| Packaging | Box of 5 |
| Sizes | Length 65 to 150 cm |
| Distribution end date | 2019-02-06 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 518-084AA | Length 135 cm | In distribution |
| 518-088AA | Length 90 cm | In distribution |
| 518-086AA | Length 150 cm | In distribution |
| 518-080AA | Length 135 cm | In distribution |
| 518-082AA | Length 150 cm | In distribution |
| 518-078AA | Length 90 cm | In distribution |
| 518-090AA | Length 135 cm | In distribution |
| 518-076AA | Length 65 cm | In distribution |
| 518-092AA | Length 150 cm | In distribution |
| 518-090 | Length 135 cm | Withdrawn |
| 518-078 | Length 90 cm | Withdrawn |
| 518-086 | Length 150 cm | Withdrawn |
| 518-082 | Length 150 cm | Withdrawn |
| 518-092 | Length 150 cm | Withdrawn |
| 518-088 | Length 90 cm | Withdrawn |
| 518-084 | Length 135 cm | Withdrawn |
| 518-076 | Length 65 cm | Withdrawn |
| 518-080 | Length 135 cm | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Launcher™ | Medtronic, Inc. | 3,805 |
| Sherpa NX Balanced™ | Medtronic, Inc. | 1,523 |
| Arrow | Teleflex Medical LLC | 1,249 |
| Z2 | Medtronic, Inc. | 955 |
| Vista Brite TIP | Cordis Corp. | 789 |
| Mach1™ | Boston Scientific Corporation | 777 |
| Sherpa NX Active | Medtronic, Inc. | 571 |
| Zuma® | Medtronic, Inc. | 569 |
| Convey | Pendracare International B.V. | 532 |
| Taiga | Medtronic, Inc. | 307 |
| RunWay™ | Boston Scientific Corporation | 300 |
| ConcierGE Guiding Excellence™ | Merit Medical Systems, Inc. | 295 |
Showing 12 of 500. All products under Catheter, Percutaneous
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K150201 | 2015-02-27 |
| K112032 | 2011-10-17 |
| K092396 | 2009-09-04 |
| K091299 | 2009-07-01 |
| K090913 | 2009-05-04 |
| K082559 | 2008-12-11 |
| K082561 | 2008-12-10 |
| K072750 | 2007-12-04 |
| K033678 | 2004-02-23 |
| K022138 | 2002-09-23 |
| K991059 | 1999-11-16 |
Recalls
The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2011-07-18 | Not classified | Package design/selection | Packaging integrity may be compromised, thus sterility can not be assured. | 123 units | 2011-08-12 |
| 2011-07-18 | Not classified | Package design/selection | Packaging integrity may be compromised, thus sterility can not be assured. | 57 units | 2011-08-12 |
| 2010-11-16 | Not classified | Device Design | Reports of distal bond failure which has resulted in peeling of the bond and/or detachment of the distal end of the scoring element. May result in vessel injury or embolism. | 17682 total units, all sizes and lots | 2011-10-04 |
| 2010-11-16 | Not classified | Device Design | Reports of distal bond failure which has resulted in peeling of the bond and/or detachment of the distal end of the scoring element. May result in vessel injury or embolism. | 17682 units, all sizes and lots | 2011-10-04 |
| 2010-11-16 | Not classified | Device Design | Reports of distal bond failure which has resulted in peeling of the bond and/or detachment of the distal end of the scoring element. May result in vessel injury or embolism. | 17682 units, all sizes and lots | 2011-10-04 |
| 2010-11-16 | Not classified | Device Design | Reports of distal bond failure which has resulted in peeling of the bond and/or detachment of the distal end of the scoring element. May result in vessel injury or embolism. | 17682 units, all sizes and lots | 2011-10-04 |
| 2010-11-16 | Not classified | Device Design | Reports of distal bond failure which has resulted in peeling of the bond and/or detachment of the distal end of the scoring element. May result in vessel injury or embolism. | 17682 units, all sizes and lots | 2011-10-04 |
| 2007-12-10 | Not classified | Packaging process control | Mislabeling: Catheters were placed into mis-labeled inner pouches as REF Number 518-037, 135 cm–the exterior box labeling is correct as 90 cm. | 64 | 2008-02-08 |