Socrates

Socrates 38 Catheter, 127cm working length.

Registry build 21.09.26
14manufacturers in China registered for this device type
2catalogue numbers in this listing
1510(k) clearance
1recall

Who Else Makes It

Concentrated in Shanghai (5), Jiangsu (5), Guangdong (3). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code DQY
Manufacturer City Province Registered as Device types
Jabil Circuit (Shanghai) Ltd. Shanghai Shanghai Contract manufacturer 31
Covidien Medical Products (Shanghai) Manufacturing LLC Shanghai Shanghai Contract manufacturer 8
Sterigenics Shanghai ETO Ltd. Shanghai Shanghai Contract manufacturer 65
Steris Sterilization Technologies (Suzhou) Ltd Suzhou Jiangsu Contract manufacturer 44
Goals Sterilization Co., Ltd. Jiaxing Zhejiang Contract manufacturer 26
Wuxi Goals Medical Technology Co., Ltd. Yixing Jiangsu Contract manufacturer 24
Suzhou Zenith Vascular Scitech Limited Suzhou Jiangsu Manufacturer 6
Haolang Technology (Foshan) Limited Corporation Foshan Guangdong Contract manufacturer 6
OrbusNeich Medical (Shenzhen) Co., Ltd. Shenzhen Guangdong Complaint-file establishment 5
Curatia Medical Limited Suzhou Jiangsu Specification developer 5
Shanghai Wallaby Medical Technologies Co., Inc. Shanghai Shanghai Contract manufacturer 5
DK Medical Technology Co., Ltd. Suzhou Jiangsu Manufacturer 3

Showing 12 of 14. All 14 manufacturers in China registered for Catheter, Percutaneous

Record

Regulatory record for Socrates
Listed by Scientia Vascular, United States
FDA product code DQY
Device type Catheter, Percutaneous
Device class Class 2
Regulation 21 CFR 870.1250
Establishment Manufacturer
510(k) K223913
Record published 2025-05-27
Record revised 2025-06-24 (version 2)

Specifications

Specifications
MRI safety MR Unsafe
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number, expiry date
Storage Storage environment temperature 0 to 35 °C; Special storage condition: Keep dry
Sizes Outer diameter 0.053 in; catheter inner diameter 0.96 mm; catheter gauge 4 Fr; outer diameter 1.35 mm; catheter inner diameter 0.038 in; catheter working length 127 to 156 cm

Catalogue Numbers

Catalogue numbers for Socrates
Catalogue number Size Status
SC038-127-001 Outer Diameter 0.053 in In distribution
SC038-156-001 Outer Diameter 0.053 in In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Launcher™ Medtronic, Inc. 3,805
Sherpa NX Balanced™ Medtronic, Inc. 1,523
Arrow Teleflex Medical LLC 1,249
Z2 Medtronic, Inc. 955
Vista Brite TIP Cordis Corp. 789
Mach1™ Boston Scientific Corporation 777
Sherpa NX Active Medtronic, Inc. 571
Zuma® Medtronic, Inc. 569
Convey Pendracare International B.V. 532
Taiga Medtronic, Inc. 307
RunWay™ Boston Scientific Corporation 300
ConcierGE Guiding Excellence™ Merit Medical Systems, Inc. 295

Showing 12 of 500. All products under Catheter, Percutaneous

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K210601 2021-04-28

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Socrates
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Scientia Vascular 510(k) number 2025-01-02 Class II Under Investigation by firm Due to manufacturing non-conformance that resulted in channels in the seal on the packaging pouch. As a result, this could potential create a breach in the sterile barrier. 120 devices

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2023-02-01 Class II Device Design Microcatheters for embolic coil and diagnostic agent introduction to peripheral/neuro vasculature, due to manufacturing non-conformance, and due to flush, guidewire insertion and manipulation prior to placement, may have loose particles wit 353

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer