Sublime Microcatheter, 018, 200cm, Angle
The Sublime microcatheter provides access to peripheral blood vessels to help place or exchange guidewires. Its lumen can also deliver saline or diagnostic contrast. The listed version has…
The Sublime microcatheter provides access to peripheral blood vessels to help place or exchange guidewires. Its lumen can also deliver saline or diagnostic contrast. The listed version has an angled tip, a 200 cm working length and compatibility with a 0.018-inch guidewire.
The catheter advances over a guidewire and supports it through difficult vessel segments. A stainless steel braid reinforces the shaft, while a hydrophilic coating provides a lubricious surface. A distal radiopaque marker helps locate the tip under fluoroscopy.
Connection and Supply
A proximal Luer fitting provides access to the single lumen. The catheter is compatible with a 4 French guide catheter and is supplied sterile following ethylene oxide sterilization for a single use.
Who Else Makes It
Concentrated in Shanghai (5), Jiangsu (5), Guangdong (3). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Jabil Circuit (Shanghai) Ltd. | Shanghai | Shanghai | Contract manufacturer | 31 |
| Covidien Medical Products (Shanghai) Manufacturing LLC | Shanghai | Shanghai | Contract manufacturer | 8 |
| Sterigenics Shanghai ETO Ltd. | Shanghai | Shanghai | Contract manufacturer | 65 |
| Steris Sterilization Technologies (Suzhou) Ltd | Suzhou | Jiangsu | Contract manufacturer | 44 |
| Goals Sterilization Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 26 |
| Wuxi Goals Medical Technology Co., Ltd. | Yixing | Jiangsu | Contract manufacturer | 24 |
| Suzhou Zenith Vascular Scitech Limited | Suzhou | Jiangsu | Manufacturer | 6 |
| Haolang Technology (Foshan) Limited Corporation | Foshan | Guangdong | Contract manufacturer | 6 |
| OrbusNeich Medical (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Complaint-file establishment | 5 |
| Curatia Medical Limited | Suzhou | Jiangsu | Specification developer | 5 |
| Shanghai Wallaby Medical Technologies Co., Inc. | Shanghai | Shanghai | Contract manufacturer | 5 |
| DK Medical Technology Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 3 |
Showing 12 of 14. All 14 manufacturers in China registered for Catheter, Percutaneous
Record
| Listed by | Surmodics, Inc., United States |
|---|---|
| FDA product code | DQY |
| Device type | Catheter, Percutaneous |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1250 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| 510(k) | K221886 |
| Record published | 2023-04-14 |
| Record revised | 2025-01-28 (version 2) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Sizes | Catheter length 200 cm |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| SRA-MC18-ANG200 | Catheter Length 200 cm | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Launcher™ | Medtronic, Inc. | 3,805 |
| Sherpa NX Balanced™ | Medtronic, Inc. | 1,523 |
| Arrow | Teleflex Medical LLC | 1,249 |
| Z2 | Medtronic, Inc. | 955 |
| Vista Brite TIP | Cordis Corp. | 789 |
| Mach1™ | Boston Scientific Corporation | 777 |
| Sherpa NX Active | Medtronic, Inc. | 571 |
| Zuma® | Medtronic, Inc. | 569 |
| Convey | Pendracare International B.V. | 532 |
| Taiga | Medtronic, Inc. | 307 |
| RunWay™ | Boston Scientific Corporation | 300 |
| ConcierGE Guiding Excellence™ | Merit Medical Systems, Inc. | 295 |
Showing 12 of 500. All products under Catheter, Percutaneous
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K232647 | 2023-09-29 |
| K221886 | 2022-10-14 |
| K173560 | 2018-01-12 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.