Venture® RX Catheter

Catalogue number 5820, listed by Vascular Solutions LLC, United States, under Catheter, Percutaneous. 14 manufacturers in China are registered for this product code.

Registry build 21.09.26
14manufacturers in China registered for this device type
1catalogue number
27510(k) clearances naming this product code
6recalls on this code

Who Else Makes It

Concentrated in Shanghai (5), Jiangsu (5), Guangdong (3). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code DQY
Manufacturer City Province Registered as Device types
Jabil Circuit (Shanghai) Ltd. Shanghai Shanghai Contract manufacturer 31
Covidien Medical Products (Shanghai) Manufacturing LLC Shanghai Shanghai Contract manufacturer 8
Sterigenics Shanghai ETO Ltd. Shanghai Shanghai Contract manufacturer 65
Steris Sterilization Technologies (Suzhou) Ltd Suzhou Jiangsu Contract manufacturer 44
Goals Sterilization Co., Ltd. Jiaxing Zhejiang Contract manufacturer 26
Wuxi Goals Medical Technology Co., Ltd. Yixing Jiangsu Contract manufacturer 24
Suzhou Zenith Vascular Scitech Limited Suzhou Jiangsu Manufacturer 6
Haolang Technology (Foshan) Limited Corporation Foshan Guangdong Contract manufacturer 6
OrbusNeich Medical (Shenzhen) Co., Ltd. Shenzhen Guangdong Complaint-file establishment 5
Curatia Medical Limited Suzhou Jiangsu Specification developer 5
Shanghai Wallaby Medical Technologies Co., Inc. Shanghai Shanghai Contract manufacturer 5
DK Medical Technology Co., Ltd. Suzhou Jiangsu Manufacturer 3

Showing 12 of 14. All 14 manufacturers in China registered for Catheter, Percutaneous

Record

Regulatory record for Venture® RX catheter
Listed by Vascular Solutions LLC, United States
FDA product code DQY
Device type Catheter, Percutaneous
Device class Class 2
Regulation 21 CFR 870.1250
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer
Record published 2016-09-05
Record revised 2023-06-06 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Sizes Length 145 cm
Distribution end date 2019-03-28

Catalogue Numbers

Catalogue numbers for Venture® RX catheter
Catalogue number Size Status
5820 Length 145 cm Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Launcher™ Medtronic, Inc. 3,805
Sherpa NX Balanced™ Medtronic, Inc. 1,523
Arrow Teleflex Medical LLC 1,249
Z2 Medtronic, Inc. 955
Vista Brite TIP Cordis Corp. 789
Mach1™ Boston Scientific Corporation 777
Sherpa NX Active Medtronic, Inc. 571
Zuma® Medtronic, Inc. 569
Convey Pendracare International B.V. 532
Taiga Medtronic, Inc. 307
RunWay™ Boston Scientific Corporation 300
ConcierGE Guiding Excellence™ Merit Medical Systems, Inc. 295

Showing 12 of 500. All products under Catheter, Percutaneous

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K220647 2022-08-18
K212211 2022-02-09
K210647 2021-04-30
K193119 2020-06-29
K191560 2019-08-09
K182570 2019-03-13
K180088 2018-04-04
K172090 2017-10-20
K171335 2017-06-07
K161901 2017-02-03
K162467 2017-02-01
K142065 2014-11-25
K133501 2014-02-25
K120707 2012-05-15
K112100 2012-03-20
K112082 2011-12-01
K111334 2011-08-01
K101659 2010-12-16
K091750 2009-11-04
K090977 2009-06-18
K091345 2009-06-12
K082337 2009-01-15
K072618 2007-11-21
K070372 2007-06-01
K060327 2006-04-12
K052258 2005-12-13
K052257 2005-11-23

Recalls

3 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2017-04-25 Class I Process control Vascular Solutions, Inc. (VSI) is voluntarily removing all lots of Venture catheters due to a potential problem.
Venture RX (Model 5820), Venture OTW (Model 5821), and Venture CS (Model 5822) catheters. After an internal investigation, VSI
13,551 (7,054 are unexpired) 2019-11-05
2016-09-16 Class I Process control Vascular Solutions is recalling Twin-Pass dual access catheters because there is a potential for excess manufacturing material to remain at the tip of the catheter or within the distal portion of the rapid exchange lumen. 11,670 units total 2018-05-04
2016-09-16 Class I Process control Vascular Solutions is recalling Twin-Pass dual access catheters because there is a potential for excess manufacturing material to remain at the tip of the catheter or within the distal portion of the rapid exchange lumen. 11,670 units total 2018-05-04
2013-01-29 Class II Material/Component Contamination Vascular Solutions, Inc has discovered a potential problem with a number of lots of Supercross microcatheters. A potential for surface contamination on aged catheters was observed during in-house testing. 4731 2013-06-25
2012-01-17 Not classified Material/Component Contamination Vascular Solutions has became aware of a potential defect with their 6F GuideLiner V2 catheters (Model 5571) with lot number 555038. Use of this product could result in the catheter shaft separating from the pushwire on the device. This may 330 2012-07-19
2009-07-02 Not classified Process control Three occurrences of Twin-Pass catheters containing a piece of PTFE beading material in the OTW lumen have been reported to Vascular Solutions. The PTFE beading material is a processing aide used during hydrophilic coating. The beading is t 5885 2012-04-03

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer