White Lumax
White Lumax, Catheter Guiding Coaxial Design
Who Else Makes It
Concentrated in Shanghai (5), Jiangsu (5), Guangdong (3). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Jabil Circuit (Shanghai) Ltd. | Shanghai | Shanghai | Contract manufacturer | 31 |
| Covidien Medical Products (Shanghai) Manufacturing LLC | Shanghai | Shanghai | Contract manufacturer | 8 |
| Sterigenics Shanghai ETO Ltd. | Shanghai | Shanghai | Contract manufacturer | 65 |
| Steris Sterilization Technologies (Suzhou) Ltd | Suzhou | Jiangsu | Contract manufacturer | 44 |
| Goals Sterilization Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 26 |
| Wuxi Goals Medical Technology Co., Ltd. | Yixing | Jiangsu | Contract manufacturer | 24 |
| Suzhou Zenith Vascular Scitech Limited | Suzhou | Jiangsu | Manufacturer | 6 |
| Haolang Technology (Foshan) Limited Corporation | Foshan | Guangdong | Contract manufacturer | 6 |
| OrbusNeich Medical (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Complaint-file establishment | 5 |
| Curatia Medical Limited | Suzhou | Jiangsu | Specification developer | 5 |
| Shanghai Wallaby Medical Technologies Co., Inc. | Shanghai | Shanghai | Contract manufacturer | 5 |
| DK Medical Technology Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 3 |
Showing 12 of 14. All 14 manufacturers in China registered for Catheter, Percutaneous
Record
| Listed by | Cook Incorporated, United States |
|---|---|
| FDA product code | DQY |
| Device type | Catheter, Percutaneous |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1250 |
| Establishment | Contract manufacturer, Contract steriliser, Specification developer, Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2016-09-24 |
| Record revised | 2021-12-22 (version 7) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Storage | Special storage condition: Store in dark, dry, cool place. |
| Distribution end date | 2017-08-17 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| G11164 | In distribution | |
| G27940 | In distribution | |
| G11165 | In distribution | |
| G10143 | Withdrawn | |
| G10141 | Withdrawn | |
| G10142 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Launcher™ | Medtronic, Inc. | 3,805 |
| Sherpa NX Balanced™ | Medtronic, Inc. | 1,523 |
| Arrow | Teleflex Medical LLC | 1,249 |
| Z2 | Medtronic, Inc. | 955 |
| Vista Brite TIP | Cordis Corp. | 789 |
| Mach1™ | Boston Scientific Corporation | 777 |
| Sherpa NX Active | Medtronic, Inc. | 571 |
| Zuma® | Medtronic, Inc. | 569 |
| Convey | Pendracare International B.V. | 532 |
| Taiga | Medtronic, Inc. | 307 |
| RunWay™ | Boston Scientific Corporation | 300 |
| ConcierGE Guiding Excellence™ | Merit Medical Systems, Inc. | 295 |
Showing 12 of 500. All products under Catheter, Percutaneous
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K191163 | 2019-12-12 |
| K150970 | 2015-05-12 |
| K131204 | 2014-01-29 |
| K122917 | 2013-06-28 |
| K122940 | 2013-03-19 |
| K101877 | 2010-08-06 |
| K091527 | 2009-06-12 |
| K090822 | 2009-04-27 |
| K073378 | 2007-12-28 |
| K063252 | 2006-11-14 |
| K052036 | 2005-08-25 |
| K033875 | 2004-04-02 |
| K032869 | 2003-11-19 |
| K032931 | 2003-10-22 |
| K031766 | 2003-06-26 |
| K022552 | 2002-09-27 |
| K990726 | 1999-04-02 |
| K914856 | 1992-05-01 |
| K902999 | 1991-02-01 |
| K902905 | 1990-09-04 |
| K851241 | 1986-02-26 |
| K832178 | 1983-08-12 |
Recalls
4 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2022-05-25 | Class II | Nonconforming Material/Component | The products may contain excess coating material on the outside and/or interior of the needle component. Potential adverse events that may occur if an affected product is used include a delay in the procedure, a prolonged procedure, or par | 11,451 units | |
| 2020-04-30 | Class II | Process control | The Pressure Monitoring Set and Tray may contain excess coating material on the outside and/or interior of the needle component which could cause occlusion. | 6792 | 2021-03-29 |
| 2020-04-30 | Class II | Process control | The Pressure Monitoring Set and Tray may contain excess coating material on the outside and/or interior of the needle component which could cause occlusion. | 1899 | 2021-03-29 |
| 2018-04-16 | Class II | Labeling mix-ups | Incorrect product labeling. Product labeled as 6mm x 2cm balloon are packaged with a 4mm x 4 cm balloon label and vice-versa. | 40 total products | 2019-06-27 |
| 2017-10-13 | Class II | Labeling Change Control | Label does not state that the product is heparin-coated. | 56 | 2019-10-23 |
| 2017-10-13 | Class II | Labeling Change Control | Label does not state that the product is heparin-coated. | 266 | 2019-10-23 |
| 2017-10-13 | Class II | Labeling Change Control | Label does not state that the product is heparin-coated. | 13 | 2019-10-23 |
| 2016-04-15 | Class II | Unknown/Undetermined by firm | Increase in reports of polymer degradation of the catheter tip, resulting in tip fracture and/or separation. degradation could include loss of device function, separation of a device segment leading to medical intervention, or complications | 3,425 | 2017-08-04 |
| 2016-01-06 | Class I | Process control | A manufacturing process may lead to catheter tip fracture and or separation. Potential adverse events may include loss of device function, medical intervention to retrieve a separated segment, or complications resulting from a separated ti | 2280 | 2017-08-23 |
| 2016-01-06 | Class I | Process control | A manufacturing process may lead to catheter tip fracture and or separation. Potential adverse events may include loss of device function, medical intervention to retrieve a separated segment, or complications resulting from a separated ti | 12691 | 2017-08-23 |
| 2016-01-06 | Class I | Process control | A manufacturing process may lead to catheter tip fracture and or separation. Potential adverse events may include loss of device function, medical intervention to retrieve a separated segment, or complications resulting from a separated ti | 1341 | 2017-08-23 |
| 2016-01-06 | Class I | Process control | A manufacturing process may lead to catheter tip fracture and or separation. Potential adverse events may include loss of device function, medical intervention to retrieve a separated segment, or complications resulting from a separated ti | 1515 | 2017-08-23 |
| 2007-02-28 | Not classified | Other | Mislabeled as to size: The outer label reads 7-4.0 balloon, when the balloon is actually 5-2.0. | 20 units | 2007-05-29 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.